The DOI matches its Crossref record.
Validation of EuroSCORE II in a modern cohort of patients undergoing cardiac surgery
Abstract
OBJECTIVE: We aimed to validate the new EuroSCORE II risk model in a contemporary cardiac surgery practice in the United Kingdom (UK). METHODS: The original logistic EuroSCORE was compared to EuroSCORE II with regard to accuracy of predicting in-hospital mortality. Analysis was performed on isolated coronary artery bypass grafts (CABG; n = 2913), aortic valve replacement (AVR; n = 814), mitral valve surgery (MVR; n = 340), combined AVR and CABG (n = 517), aortic (n = 350) and miscellaneous procedures (n = 642), and the above cases combined (n = 5576). RESULTS: In a single-institution experience, EuroSCORE II is a reasonable risk model for in-hospital mortality from isolated CABG (C-statistic 0.79, Hosmer-Lemeshow P = 0.052) and aortic procedures (C-statistic 0.81, Hosmer-Lemeshow P = 0.43), and excellent for mitral valve surgery (C-statistic 0.87, Hosmer-Lemeshow P = 0.6). EuroSCORE II is better than the original EuroSCORE, using contemporaneous data for combined AVR and CABG operations (C-statistic 0.74, Hosmer-Lemeshow P = 0.38). However, EuroSCORE II failed to improve on the original EuroSCORE model for isolated AVR (C-statistic 0.69, Hosmer-Lemeshow P = 0.07) and miscellaneous procedures (C-statistic 0.70, Hosmer-Lemeshow P = 0.99). EuroSCORE II has better calibration than the original EuroSCORE or the Society of Cardiothoracic Surgeons of Great Britain and Ireland (SCTS) modified EuroSCORE for cumulative sum survival (CUSUM) curves. CONCLUSIONS: EuroSCORE II improves on the original logistic EuroSCORE, though mainly for combined AVR and CABG cases. Concerns still exist, however, over its use for isolated AVR procedures, aortic surgery and miscellaneous procedures. There is still room for improvement in risk modelling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
(2014) · European Heart Journal · doi:10.1093/eurheartj/ehu278 · Cited by 4,314
2014 ESC/EACTS Guidelines on myocardial revascularization
Kolh, P., Windecker, S., Alfonso, F., Collet, J.-P., Cremer, J., Falk, V., Filippatos, G., Hamm, C., Head, S. J., Jüni, P., et al. (2014) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezu366 · Cited by 4,199
2014 ESC/EACTS Guidelines on myocardial revascularization
Windecker, S., Kolh, P., Alfonso, F., Collet, J.-P., Cremer, J., Falk, V., Filippatos, G., Hamm, C., Head, S. J., Jüni, P., et al. (2014) · Kardiologia Polska · doi:10.5603/kp.2014.0224 · Cited by 418
2014 ESC/EACTS Guidelines on myocardial revascularization
Windecker, S., Kolh, P., Alfonso, F., Collet, J.-P., Cremer, J., Falk, V., Filippatos, G., Hamm, C., Head, S. J., Jüni, P., et al. (2015) · EuroIntervention · doi:10.4244/eijy14m09_01 · Cited by 328
Guida, P., Mastro, F., Scrascia, G., Whitlock, R., & Paparella, D. (2014) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2014.07.039 · Cited by 126
Metadata
- Authors
- Chalmers, J., Pullan, M., Fabri, B., McShane, J., Shaw, M., Mediratta, N., & Poullis, M.
- Venue
- European Journal of Cardio-Thoracic Surgery
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-07-24
- Volume
- 43
- Issue
- 4
- Pages
- 688-694
- ISSN
- 1010-7940 (ISSN-L)
- 1873-734X
- OpenAlex
- W2106207839
- Cited by
- 171
- References
- 0
- FWCI
- 13.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of EuroSCORE II in a modern cohort of patients undergoing cardiac surgery. https://app.cochat.ai/papers/10.1093/ejcts/ezs406
- The paper
- Chalmers, J., Pullan, M., Fabri, B., McShane, J., Shaw, M., Mediratta, N., & Poullis, M. (2013). Validation of EuroSCORE II in a modern cohort of patients undergoing cardiac surgery. European Journal of Cardio-Thoracic Surgery. https://doi.org/10.1093/ejcts/ezs406
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.