CoChat

Decellularized aortic homografts for aortic valve and aorta ascendens replacement

Open access
Tudorache, Igor, Horke, Alexander, Cebotari, Serghei, Sarikouch, Samir, Boethig, Dietmar, Breymann, Thomas, Beerbaum, Philipp, Bertram, Harald, Westhoff-Bleck, Mechthild, Theodoridis, Karolina, Bobylev, Dmitry, Cheptanaru, Eduard, Ciubotaru, Anatol, Haverich, Axel · 2016 · European Journal of Cardio-Thoracic Surgery
Cited by 65

The DOI matches its Crossref record.

Abstract

OBJECTIVES: The choice of valve prosthesis for aortic valve replacement (AVR) in young patients is challenging. Decellularized pulmonary homografts (DPHs) have shown excellent results in pulmonary position. Here, we report our early clinical results using decellularized aortic valve homografts (DAHs) for AVR in children and mainly young adults. METHODS: This prospective observational study included all 69 patients (44 males) operated from February 2008 to September 2015, with a mean age of 19.7 ± 14.6 years (range 0.2-65.3 years). In 18 patients, a long DAH was used for simultaneous replacement of a dilated ascending aorta as an extended aortic root replacement (EARR). Four patients received simultaneous pulmonary valve replacement with DPH. RESULTS: Thirty-nine patients (57%) had a total of 62 previous operations. The mean aortic cross-clamp time in isolated cases was 129 ± 41 min. There was 1 conduit-unrelated death. The mean DAH diameter was 22.4 ± 3.7 mm (range, 10-29 mm), the average peak gradient was 14 ± 15 mmHg and the mean aortic regurgitation grade (0.5 = trace, 1 = mild) was 0.6 ± 0.5. The mean effective orifice area (EOA) of 25 mm diameter DAH was 3.07 ± 0.7 cm(2). DAH annulus z-values were 1.1 ± 1.1 at implantation and 0.7 ± 1.3 at the last follow-up. The last mean left ventricle ejection fraction and left ventricle end diastolic volume index was 63 ± 7% and 78 ± 16 ml/m(2) body surface area, respectively. To date, no dilatation has been observed at any level of the graft during follow-up; however, the observational time is short (140.4 years in total, mean 2.0 ± 1.8 years, maximum 7.6 years). One small DAH (10 mm at implantation) had to be explanted due to subvalvular stenosis and developing regurgitation after 4.5 years and was replaced with a 17 mm DAH without complication. No calcification of the explanted graft was noticed intraoperatively and after histological analysis, which revealed extensive recellularization without inflammation. CONCLUSIONS: DAHs withstand systemic circulation, provide outstanding EOA and appear as an alternative to conventional grafts for AVR in young patients. EARR using DAH is a further option in aortic valve disease associated with aorta ascendens dilatation as it avoids the use of any prosthetic material.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ejcts/ezw013

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 65

Metadata

Authors
Tudorache, I., Horke, A., Cebotari, S., Sarikouch, S., Boethig, D., Breymann, T., Beerbaum, P., Bertram, H., Westhoff-Bleck, M., Theodoridis, K., Bobylev, D., Cheptanaru, E., Ciubotaru, A., & Haverich, A.
Venue
European Journal of Cardio-Thoracic Surgery
Published
2016-02-18
Volume
50
Issue
1
Pages
89-97
ISSN
  • 1010-7940 (ISSN-L)
  • 1873-734X
OpenAlex
W2277824627
Cited by
65
References
0
FWCI
5.56
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Decellularized aortic homografts for aortic valve and aorta ascendens replacement. https://app.cochat.ai/papers/10.1093/ejcts/ezw013
The paper
Tudorache, I., Horke, A., Cebotari, S., Sarikouch, S., Boethig, D., Breymann, T., Beerbaum, P., Bertram, H., Westhoff-Bleck, M., Theodoridis, K., Bobylev, D., Cheptanaru, E., Ciubotaru, A., & Haverich, A. (2016). Decellularized aortic homografts for aortic valve and aorta ascendens replacement. European Journal of Cardio-Thoracic Surgery. https://doi.org/10.1093/ejcts/ezw013

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.