Comparative performance of transcatheter aortic valve-in-valve implantation versus conventional surgical redo aortic valve replacement in patients with degenerated aortic valve bioprostheses: systematic review and meta-analysis
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The objective of this report was to directly compare, by means of a systematic review and meta-analysis, redo surgical aortic valve replacement (re-sAVR) with valve-in-valve transcatheter aortic valve implantation (ViV TAVI) for patients with failed degenerated aortic bioprostheses. Multiple databases were screened for all available reports comparing ViV TAVI with re-sAVR in patients with failing degenerated aortic bioprostheses. The primary outcome was all-cause mortality determined from the longest available survival data. Five observational studies (n = 342) were included in the meta-analysis; patients in the ViV TAVI group were older and had a higher baseline risk compared to those in the re-sAVR group. Although there was no statistical difference in procedural mortality [risk ratio (RR) 0.74, 95% confidence interval (CI) 0.18-2.97; P = 0.67], 30-day mortality (RR 1.29, 95% CI 0.44-3.78; P = 0.64) and cardiovascular mortality (RR 0.91, 95% CI 0.30-2.70; P = 0.86) at a mean follow-up period of 18 months, cumulative survival analysis favoured surgery with borderline statistical significance (ViV TAVI versus re-sAVR: hazard ratio 1.91, 95% CI 1.03-3.57; P = 0.039). ViV TAVI was associated with a significantly lower rate of permanent pacemaker implantations (RR 0.37, 95% CI 0.20-0.68; P = 0.002) and shorter intensive care unit (P < 0.001) and hospital stays (P = 0.020). In contrast, re-sAVR offered superior echocardiographic outcomes: lower incidence of patient-prosthesis mismatch (P = 0.008), fewer paravalvular leaks (P = 0.023) and lower mean postoperative aortic valve gradients in the prespecified analysis (P = 0.017). The ViV TAVI approach is a safe and feasible alternative to re-sAVR that may offer an effective, less invasive treatment for patients with failed surgical aortic valve bioprostheses who are inoperable or at high risk. Re-sAVR should remain the standard of care, particularly in the low-risk population, because it offers superior haemodynamic outcomes with low mortality rates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions
Sterne, J. A., Hernán, M. A., Reeves, B. C., Savović, J., Berkman, N. D., Viswanathan, M., Henry, D., Altman, D. G., Ansari, M. T., Boutron, I., et al. (2016) · BMJ · doi:10.1136/bmj.i4919 · Cited by 20,329
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis
Adams, D. H., Popma, J. J., Reardon, M. J., Yakubov, S. J., Coselli, J. S., Deeb, G. M., Gleason, T. G., Buchbinder, M., Hermiller, J., Kleiman, N. S., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1400590 · Cited by 2,902
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000029 · Cited by 2,566
Mack, M. J., Leon, M. B., Smith, C. R., Miller, D. C., Moses, J. W., Tuzcu, E. M., Webb, J. G., Douglas, P. S., Anderson, W. N., Blackstone, E. H., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)60308-7 · Cited by 1,739
Brown, J. M., O'Brien, S. M., Wu, C., Sikora, J. A. H., Griffith, B. P., & Gammie, J. S. (2009) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2008.08.015 · Cited by 937
Transcatheter Aortic Valve Implantation in Failed Bioprosthetic Surgical Valves
Dvir, D., Webb, J. G., Bleiziffer, S., Pasic, M., Waksman, R., Kodali, S., Barbanti, M., Latib, A., Schaefer, U., Rodés-Cabau, J., et al. (2014) · JAMA · doi:10.1001/jama.2014.7246 · Cited by 923
Cited by
2021 ESC/EACTS Guidelines for the management of valvular heart disease
Vahanian, A., Beyersdorf, F., Praz, F., Milojevic, M., Baldus, S., Bauersachs, J., Capodanno, D., Conradi, L., De Bonis, M., De Paulis, R., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehab395 · Cited by 5,685
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Circulation · doi:10.1161/cir.0000000000000923 · Cited by 3,686
2020 ACC/AHA Guideline for the Management of Patients With Valvular Heart Disease
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.11.018 · Cited by 1,982
2021 ESC/EACTS Guidelines for the management of valvular heart disease
Beyersdorf, F., Vahanian, A., Milojevic, M., Praz, F., Baldus, S., Bauersachs, J., Capodanno, D., Conradi, L., De Bonis, M., De Paulis, R., et al. (2021) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezab389 · Cited by 622
Vahanian, A., Beyersdorf, F., Praz, F., Milojevic, M., Baldus, S., Bauersachs, J., Capodanno, D., Conradi, L., De Bonis, M., De Paulis, R., et al. (2022) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2022.05.006 · Cited by 527
2021 ESC/EACTS Guidelines for the management of valvular heart disease
Vahanian, A., Beyersdorf, F., Praz, F., Milojevic, M., Baldus, S., Bauersachs, J., Capodanno, D., Conradi, L., De Bonis, M., De Paulis, R., et al. (2022) · EuroIntervention · doi:10.4244/eij-e-21-00009 · Cited by 372
JCS/JSCS/JATS/JSVS 2020 Guidelines on the Management of Valvular Heart Disease
Izumi, C., Eishi, K., Ashihara, K., Arita, T., Otsuji, Y., Kunihara, T., Komiya, T., Shibata, T., Seo, Y., Daimon, M., et al. (2020) · Circulation Journal · doi:10.1253/circj.cj-20-0135 · Cited by 367
2020 ACC/AHA guideline for the management of patients with valvular heart disease
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2021.04.002 · Cited by 279
Metadata
- Authors
- Gozdek, M., Raffa, G. M., Suwalski, P., Kołodziejczak, M., Anisimowicz, L., Kubica, J., Navarese, E. P., Kowalewski, M., & SIRIO-TAVI group
- Venue
- European Journal of Cardio-Thoracic Surgery
- Publisher
- Oxford University Press (OUP)
- Published
- 2017-10-04
- Volume
- 53
- Issue
- 3
- Pages
- 495-504
- ISSN
- 1010-7940 (ISSN-L)
- 1873-734X
- OpenAlex
- W2784240861
- Cited by
- 76
- References
- 7
- FWCI
- 2.22
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.