CoChat

Assessment of interventricular and right-intraventricular dyssynchrony in patients with surgically repaired tetralogy of Fallot by two-dimensional speckle tracking

Mueller, Matthias, Rentzsch, Axel, Hoetzer, Kai, Raedle-Hurst, Tanja, Boettler, Petra, Stiller, Brigitte, Lemmer, Julia, Sarikouch, Samir, Beerbaum, Philipp, Peters, Brigitte, Vogt, Manfred, Vogel, Michael, Abdul-Khaliq, Hashim · 2010 · European Heart Journal - Cardiovascular Imaging
Cited by 45

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

AIMS: We aimed to assess interventricular and right-intraventricular dyssynchrony in patients after tetralogy of Fallot (TOF) repair by two-dimensional (2D) speckle tracking and to identify factors associated with dyssynchrony. METHODS AND RESULTS: Forty-two patients after TOF repair with a mean age of 19.8 years and 42 age-matched healthy controls were studied. Longitudinal myocardial deformation (strain) and time-to-peak intervals were assessed by 2D speckle tracking and tissue Doppler imaging (TDI) in an apical four-chamber view. Dyssynchrony was defined as delay above 3 standard deviations of mean values in the control group. Magnetic resonance imaging (MRI) was performed for evaluation of ventricular function. Using 2D speckle tracking, 22 patients (52%) showed interventricular dyssynchrony and 16 (38%) had right-intraventricular dyssynchrony. The interventricular delay correlated significantly with right ventricular (RV) strain (r = 0.687, P < 0.001), RV systolic pressure (r = 0.535, P = 0.001), QRS duration (r = 0.466, P = 0.002), RV end-diastolic (r = 0.377, P = 0.018), and RV end-systolic volumes (r = 0.452, P = 0.004) as well as RV ejection fraction (r = -0.378, P = 0.018). Similarly, the right-intraventricular delay correlated significantly with RV strain (r = 0.534, P < 0.001), QRS duration (r = 0.428, P = 0.005), RV end-systolic volume (r = 0.34, P = 0.038), and RV systolic pressure (r = 0.413, P = 0.015). In multivariate regression analysis, reduced RV strain and prolonged QRS duration remained the main determinant factors predicting dyssynchrony. Moreover, 2D speckle tracking and TDI showed a significant correlation in the assessment of the interventricular (r = 0.738, P < 0.001) and right-intraventricular delay (r = 0.747, P < 0.001). CONCLUSION: Interventricular and right-intraventricular dyssynchrony are detectable in patients after TOF repair by 2D speckle tracking. Reduced RV myocardial deformation and QRS prolongation are the main factors associated with the observed dyssynchrony.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ejechocard/jeq067

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 45

Metadata

Authors
Mueller, M., Rentzsch, A., Hoetzer, K., Raedle-Hurst, T., Boettler, P., Stiller, B., Lemmer, J., Sarikouch, S., Beerbaum, P., Peters, B., Vogt, M., Vogel, M., & Abdul-Khaliq, H.
Venue
European Heart Journal - Cardiovascular Imaging
Published
2010-05-30
Volume
11
Issue
9
Pages
786-792
ISSN
  • 2047-2404 (ISSN-L)
  • 2047-2412
OpenAlex
W2065117209
Cited by
45
References
2
FWCI
2.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of interventricular and right-intraventricular dyssynchrony in patients with surgically repaired tetralogy of Fallot by two-dimensional speckle tracking. https://app.cochat.ai/papers/10.1093/ejechocard/jeq067
The paper
Mueller, M., Rentzsch, A., Hoetzer, K., Raedle-Hurst, T., Boettler, P., Stiller, B., Lemmer, J., Sarikouch, S., Beerbaum, P., Peters, B., Vogt, M., Vogel, M., & Abdul-Khaliq, H. (2010). Assessment of interventricular and right-intraventricular dyssynchrony in patients with surgically repaired tetralogy of Fallot by two-dimensional speckle tracking. European Heart Journal - Cardiovascular Imaging. https://doi.org/10.1093/ejechocard/jeq067

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.