CoChat

Dynamic assessment of 'valvular reserve capacity' in patients with rheumatic mitral stenosis

Grimaldi, A., Olivotto, I., Figini, F., Pappalardo, F., Capritti, E., Ammirati, E., Maisano, F., Benussi, S., Fumero, A., Castiglioni, A., De Bonis, M., Vermi, A. C., Colombo, A., Zangrillo, A., Alfieri, O. · 2012 · European Heart Journal - Cardiovascular Imaging
Cited by 46

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

AIMS: Mitral stenosis (MS) may exhibit a dynamic valvular reserve. When resting gradients and systolic pulmonary pressure (sPAP) do not reflect the real severity of the disease, a dynamic evaluation becomes necessary. The aim of the study was to assess the clinical utility of exercise echocardiography in symptomatic patients with apparently subcritical MS. METHODS AND RESULTS: One hundred and thirty consecutive patients were referred for symptomatic MS. Patients with unimpressive resting MVA (>1-1.5 cm(2)) and mean PG (≥5-9 mmHg) underwent exercise echocardiography. Cardiac performance and mitral indices (MVA, peak/mean PG, sPAP) were measured. Exhaustion of valvular reserve capacity under exercise was defined as appearance of symptoms and sPAP > 60 mmHg. Forty-six patients (35%) (age: 53 ± 10 years; 74%, female) with resting MVA (1.2 ± 0.36 cm(2)), mean PG (6.8 ± 2.7 mmHg), and sPAP (38 ± 7 mmHg) inconsistent with symptoms underwent stress echocardiography. Exercise was stopped for dyspnoea (76%) or fatigue (24%). At peak workloads (57.2 ± 21.8 Watts), increased mean PG (17.2 ± 4.8 mmHg, P< 0.001) and sPAP (67.4 ± 11.4 mmHg; P< 0.0001) were observed, without change in MVA (1.25 ± 0.4 cm(2); P= n.s.). At univariate analysis, predictors of adaptation to exercise were age (-0.345; P = 0.024), mean PG (0.339; P= 0.023), and sPAP (0.354; P= 0.024); at multivariate analysis, best predictor was resting mean PG, although correlation was poor (-0.339; P= 0.015). CONCLUSION: In MS with limiting symptoms despite unimpressive findings at rest, valvular capacity exhaustion should be tested on a dynamic background, as no single resting index can predict potential haemodynamic adaptation to exercise. In such context, the contribution of exercise echocardiography remains extremely valuable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ejechocard/jer269

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 46

Metadata

Authors
Grimaldi, A., Olivotto, I., Figini, F., Pappalardo, F., Capritti, E., Ammirati, E., Maisano, F., Benussi, S., Fumero, A., Castiglioni, A., De Bonis, M., Vermi, A. C., Colombo, A., Zangrillo, A., & Alfieri, O.
Venue
European Heart Journal - Cardiovascular Imaging
Published
2011-12-05
Volume
13
Issue
6
Pages
476-482
ISSN
  • 2047-2404 (ISSN-L)
  • 2047-2412
OpenAlex
W2135873798
Cited by
46
References
1
FWCI
3.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dynamic assessment of 'valvular reserve capacity' in patients with rheumatic mitral stenosis. https://app.cochat.ai/papers/10.1093/ejechocard/jer269
The paper
Grimaldi, A., Olivotto, I., Figini, F., Pappalardo, F., Capritti, E., Ammirati, E., Maisano, F., Benussi, S., Fumero, A., Castiglioni, A., De Bonis, M., Vermi, A. C., Colombo, A., Zangrillo, A., & Alfieri, O. (2012). Dynamic assessment of 'valvular reserve capacity' in patients with rheumatic mitral stenosis. European Heart Journal - Cardiovascular Imaging. https://doi.org/10.1093/ejechocard/jer269

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.