A comparison of the forces required to produce tooth movement in vitro using two self-ligating brackets and a pre-adjusted bracket employing two types of ligation
The DOI matches its Crossref record.
Abstract
Friction in fixed appliance systems has received considerable attention in the recent literature, although that attributable to the type of ligation used has not been fully investigated. This in vitro study of 0.022 x 0.028 inch slot Minitwin, Activa ('A' Company, San Diego, California, USA), and SPEED brackets (Strite Industries Ltd., Cambridge, Ontario, Canada), investigates friction in two forms of self-ligating brackets and in two methods of ligating Minitwin straight wire brackets with polyurethane elastomeric ligatures. The resistance to sliding of rectangular archwires through the ligated brackets was measured on a vertically mounted Instron testing machine. The stainless steel archwires used were straight lengths of 0.016" x 0.022", 0.017" x 0.025", 0.018" x 0.025", and 0.019" x 0.025" Nubryte Gold (GAC International Inc., Central Islip, New York, USA). The results showed a significant reduction (P < 0.01) in frictional resistance in the Activa brackets compared with SPEED brackets by a factor of approximately 15. When the SPEED brackets were compared to Minitwin brackets, the reduction in friction was by 50-70 per cent (P < 0.01). The placing of 'figure-of-eight' elastomeric ties increased friction by a factor of 70-220 per cent compared to conventional elastomeric ties (P < 0.01) except for 0.016" x 0.022" archwires. The results indicate that self-ligating brackets require less force to produce tooth movement because they apply less frictional contact to the archwire than conventionally tied siamese brackets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Systematic review of self-ligating brackets
Chen, S. S.-H., Greenlee, G. M., Kim, J.-E., Smith, C. L., & Huang, G. J. (2010) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2009.11.009 · Cited by 207
Pandis, N., Polychronopoulou, A., & Eliades, T. (2007) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2006.01.030 · Cited by 206
“This brings several favorable features to treatment, including the elimination of potential cross-contamination with elastic ligatures, consistently full engagement without the undesirable force relaxation of elastomeric modules, supposed reduced risk for enamel decalcification from the elimination of the retentive si…”
Self-ligating brackets: where are we now?
Harradine, N. W. T. (2003) · Journal of Orthodontics · doi:10.1093/ortho/30.3.262 · Cited by 195
Self-ligating vs conventional twin brackets during en-masse space closure with sliding mechanics
Miles, P. G. (2007) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2007.04.028 · Cited by 101
Metadata
- Authors
- Sims, A. P. T., Waters, N. E., Birnie, D. J., & Pethybridge, R. J.
- Venue
- The European Journal of Orthodontics
- Publisher
- Oxford University Press (OUP)
- Published
- 1993-10-01
- Volume
- 15
- Issue
- 5
- Pages
- 377-385
- ISSN
- 0141-5387 (ISSN-L)
- 1460-2210
- OpenAlex
- W2118181981
- Cited by
- 159
- References
- 0
- FWCI
- 3.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comparison of the forces required to produce tooth movement in vitro using two self-ligating brackets and a pre-adjusted bracket employing two types of ligation. https://app.cochat.ai/papers/10.1093/ejo/15.5.377
- The paper
- Sims, A. P. T., Waters, N. E., Birnie, D. J., & Pethybridge, R. J. (1993). A comparison of the forces required to produce tooth movement in vitro using two self-ligating brackets and a pre-adjusted bracket employing two types of ligation. The European Journal of Orthodontics. https://doi.org/10.1093/ejo/15.5.377
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.