Frictional forces related to self-ligating brackets
The DOI matches its Crossref record.
Abstract
Orthodontic tooth movement can be regarded as teeth sliding on a wire like pearls on a string, the force being supplied by springs or elastics. The movement implies friction between wire and bracket, taking up part of the force and leaving an uncontrolled amount to act on the teeth. The friction is likely to depend on bracket construction and wire material. Therefore, in this investigation the friction of self-ligating brackets and beta-titanium wires was evaluated, as opposed to more conventional configurations. Carried by low-friction linear ball bearings, a bracket was made to slide along an out-stretched archwire with minimal (and known) basic friction, either parallel or at an angle to the wire. Two self-ligating brackets were used in their closed position without any normal force. Friction was tested against four wires: stainless steel and beta-titanium, both in round and rectangular cross-sections. The force used to overcome friction and to move the bracket was measured on a testing machine at 10 mm/min, and the basic friction was subtracted. The results show that round wires had a lower friction than rectangular wires, the beta-titanium wires had a markedly higher friction than stainless steel wires, and friction increased with angulation for all bracket/wire combinations. The self-ligating brackets had a markedly lower friction than conventional brackets at all angulations, and self-ligating brackets, closed by the capping of a conventional design, exhibited a significantly lower friction than self-ligating brackets closed by a spring. The selection of bracket design, wire material, and wire cross-section significantly influences the forces acting in a continuous arch system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Systematic review of self-ligating brackets
Chen, S. S.-H., Greenlee, G. M., Kim, J.-E., Smith, C. L., & Huang, G. J. (2010) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2009.11.009 · Cited by 207
“Berger and Byloff(14) 2001 Cross-sectional SPEED (20) (Strite Industries) Damon SL (20) (Ormco/’’A’’ Company) Time (20) (Adenta) Twinlock (20) (Ormco/’’A’’ Company) Mini-twin (40) (Ormco/’’A’’ Company) Not reported Total opening and closing time was significantly less for each of the 4 SL designs compared with convent…”
Pandis, N., Polychronopoulou, A., & Eliades, T. (2007) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2006.01.030 · Cited by 206
“This brings several favorable features to treatment, including the elimination of potential cross-contamination with elastic ligatures, consistently full engagement without the undesirable force relaxation of elastomeric modules, supposed reduced risk for enamel decalcification from the elimination of the retentive si…”
Self-ligating brackets: where are we now?
Harradine, N. W. T. (2003) · Journal of Orthodontics · doi:10.1093/ortho/30.3.262 · Cited by 195
Self-ligating vs conventional twin brackets during en-masse space closure with sliding mechanics
Miles, P. G. (2007) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2007.04.028 · Cited by 101
Pieroni, M., Ferraz Facury, A. G. B., Santamaria-Jr, M., Correr, A. B., Correr-Sobrinho, L., Vedovello Filho, M., Costa, A. R., & Neves, J. G. (2022) · International Orthodontics · doi:10.1016/j.ortho.2022.100633 · Cited by 6
Metadata
- Authors
- Pizzoni, L.
- Venue
- The European Journal of Orthodontics
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-06-01
- Volume
- 20
- Issue
- 3
- Pages
- 283-291
- ISSN
- 0141-5387 (ISSN-L)
- 1460-2210
- OpenAlex
- W2139087560
- Cited by
- 213
- References
- 0
- FWCI
- 1.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.