Glass fibre reinforced versus multistranded bonded orthodontic retainers: a 2 year prospective multi-centre study
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
The objective of this study was to compare glass fibre reinforced (GFR) with multistranded bonded orthodontic retainers in terms of success rate and periodontal implications. A 2 year parallel study was conducted of 184 patients scheduled to receive bonded retainers in the upper and lower anterior segments. In three centres, the patients (mean age 14 years; 90 males and 94 females) were sequentially assigned to receive GFR retainers containing 500 unidirectional glass fibres (GFR500), 1000 unidirectional glass fibres (GFR1000), or multistranded retainers (gold standard). Retainer failures and periodontal conditions were monitored every 6 months. In a control group of 90 subjects without retainers, periodontal conditions were examined (negative control). Of the 274 recruited patients, 15 dropped out during the 2 year study period. Kaplan-Meier plots were drawn to assess survival of the different retainers. The Mantel-Cox log-rank test was used to identify significant differences in survival functions among the groups. Repeated measures analysis of variance and appropriate post hoc tests were adopted to evaluate periodontal conditions over time. GFR retainers showed unacceptably high failure rates in comparison with multistranded retainers (51 versus 12 per cent). The most significant periodontal conditions were found in patients with GFR retainers with no significant differences between the GFR500 and the GFR1000 group for any parameter at any time point. Subjects without retainers showed significantly lower levels of gingival inflammation and plaque accumulation when compared with patients in any retainer group. Multistranded retainers should remain the gold standard for orthodontic retention, although periodontal complications are common. The use of GFR retainers should be discouraged in daily practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comparative cleansing efficiency of manual and power brushing
Quigley, G. A., & Hein, J. W. (1962) · The Journal of the American Dental Association · doi:10.14219/jada.archive.1962.0184 · Cited by 1,020
A 3-year follow-up study of various types of orthodontic canine-to-canine retainers
Artun, J., Spadafora, A. T., & Shapiro, P. A. (1997) · The European Journal of Orthodontics · doi:10.1093/ejo/19.5.501 · Cited by 215 · cited 1×
“In this study, periodontal parameters were not recorded prior to the start of the study, as these would have been influenced by the former impact of the orthodontic appliances (Årtun et al., 1997).”
BackgroundLong-term periodontal status of patients with mandibular lingual fixed retention
Pandis, N., Vlahopoulos, K., Madianos, P., & Eliades, T. (2007) · The European Journal of Orthodontics · doi:10.1093/ejo/cjm042 · Cited by 156
Årtun, J. (1984) · American Journal of Orthodontics · doi:10.1016/0002-9416(84)90302-6 · Cited by 120 · cited 2×
“Studies have indicated acceptable compatibility of metal-bonded retainers with periodontal health (Årtun, 1984; Årtun et al., 1987, 1997; Heier et al., 1997; Booth et al., 2008).”
BackgroundPeriodontal implications of bonded versus removable retainers
Heier, E. E., Smit, A. D., Wijgaerts, I. A., & Adriaens, P. A. (1997) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/s0889-5406(97)70225-7 · Cited by 91
Årtun, J., Spadafora, A. T., Shapiro, P. A., McNeill, R. W., & Chapko, M. K. (1987) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.1987.tb00948.x · Cited by 71
Cited by
Retention procedures for stabilising tooth position after treatment with orthodontic braces
Littlewood, S. J., Millett, D. T., Doubleday, B., Bearn, D. R., & Worthington, H. V. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd002283.pub4 · Cited by 370
The effects of fixed and removable orthodontic retainers: a systematic review
Al-Moghrabi, D., Pandis, N., & Fleming, P. S. (2016) · Progress in Orthodontics · doi:10.1186/s40510-016-0137-x · Cited by 115
The effects of fixed orthodontic retainers on periodontal health: A systematic review
Arn, M.-L., Dritsas, K., Pandis, N., & Kloukos, D. (2020) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2019.10.010 · Cited by 87
Stability and Side Effects of Orthodontic Retainers - A Systematic Review
Westerlund, A. (2014) · Dentistry · doi:10.4172/2161-1122.1000258 · Cited by 26
“(2010) [20] Case-series c 2 years Fixed retainer 184 14 90/94 Gingivitis Plaque Retainer failure a Case-series were only used to record complications.”
Background
Metadata
- Authors
- Tacken, M. P. E., Cosyn, J., De Wilde, P., Aerts, J., Govaerts, E., & Vannet, B. V.
- Venue
- The European Journal of Orthodontics
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-10-16
- Volume
- 32
- Issue
- 2
- Pages
- 117-123
- ISSN
- 0141-5387 (ISSN-L)
- 1460-2210
- OpenAlex
- W2111091107
- Cited by
- 102
- References
- 6
- FWCI
- 2.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.