Temperature-controlled radiofrequency catheter ablation of AV conduction: first clinical experience
The DOI matches its Crossref record.
Abstract
A new technique for catheter ablation of atrioventricular (AV) conduction, using temperature-controlled radiofrequency energy and a bipolar asymmetrical electrode configuration, was applied to 12 patients (mean age, 48 +/- 15 years; range, 18-69 years) with medically refractory atrioventricular nodal reentrant tachycardia (AVNRT) or rapid atrial rhythms. The energy source was a 500 kHz generator with automatic power regulation to a preselected temperature of 80 degrees C. A specially designed 7 F bipolar asymmetric thermo-catheter was used for ablation in all cases. The endpoints of the procedure were: first-degree AV block in patients with AVNRT and third-degree block in patients with atrial fibrillation or flutter. Energy was applied over a range of 1-14 times per patient. After a mean follow-up of 8 +/- 4 months, third- or first-degree AV block persisted in eight patients. In comparison to constant-power radiofrequency ablation, where impedance rises are commonly observed, no impedance rise or coating of the electrode occurred during any of the 97 energy applications in this study. Variable wall contact of the electrode was identified in 20 of 97 applications by a slow temperature rise or a drop in temperature and frequent power adjustments. Thus, monitoring temperature and automatic power regulation may help to reduce the total delivered energy. Temperature control during radiofrequency energy avoids coagulum formation and consequently the associated potential hazards of constant-power application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
International Union of Pharmacology. XXIII. The Angiotensin II Receptors
de Gasparo, M., Catt, K. J., Inagami, T., Wright, J. W., & Unger, T. (2000) · Pharmacological Reviews · doi:10.1016/s0031-6997(24)01458-3 · Cited by 2,132
Cardiac Fibroblast: The Renaissance Cell
Souders, C. A., Bowers, S. L. K., & Baudino, T. A. (2009) · Circulation Research · doi:10.1161/circresaha.109.209809 · Cited by 984
Left atrial function: physiology, assessment, and clinical implications
Blume, G. G., Mcleod, C. J., Barnes, M. E., Seward, J. B., Pellikka, P. A., Bastiansen, P. M., & Tsang, T. S. M. (2011) · European Journal of Echocardiography · doi:10.1093/ejechocard/jeq175 · Cited by 518
Cardiac fibroblasts: friend or foe?
Baudino, T. A., Carver, W., Giles, W., & Borg, T. K. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00023.2006 · Cited by 427
Muhlestein, J. B., Hammond, E. H., Carlquist, J. F., Radicke, E., Thomson, M. J., Karagounis, L. A., Woods, M. L., & Anderson, J. L. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(96)00055-1 · Cited by 420
Metadata
- Authors
- HOFFMANN, E., MATTKE, S., DORWARTH, U., MULLER, D., HABERL, R., & STEINBECK, G.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 1993-01-01
- Volume
- 14
- Issue
- 1
- Pages
- 57-64
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2084856456
- Cited by
- 84
- References
- 0
- FWCI
- 3.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Temperature-controlled radiofrequency catheter ablation of AV conduction: first clinical experience. https://app.cochat.ai/papers/10.1093/eurheartj/14.1.57
- The paper
- HOFFMANN, E., MATTKE, S., DORWARTH, U., MULLER, D., HABERL, R., & STEINBECK, G. (1993). Temperature-controlled radiofrequency catheter ablation of AV conduction: first clinical experience. European Heart Journal. https://doi.org/10.1093/eurheartj/14.1.57
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.