Non-invasive magnetocardiographic localization of ventricular pre-excitation in the Wolff-Parkinson-White syndrome using a realistic torso model
The DOI matches its Crossref record.
Abstract
This study was performed to evaluate the accuracy of magnetocardiography in non-invasive localization of the ventricular pre-excitation site in patients suffering from the Wolff-Parkinson-White (WPW) syndrome. Twelve WPW patients were studied, in whom the pre-excitation caused serious supraventricular arrhythmias refractory to drug therapy. Magnetocardiographic measurements were performed in a magnetically shielded room, and non-invasive localization was computed from preprocessed magnetic signals using a current dipole source in a realistically shaped digital torso. All patients underwent intra-operative multicatheter mapping and subsequent dissection of the accessory atrioventricular connection. The intra-operative localization results were marked on magnetic resonance images of the heart, where magnetocardiographic results were also superimposed to allow comparison. The average of the three-dimensional differences between the magnetocardiographic and the invasive results was 2.1 +/- 0.9 cm. In all cases, the computed localization result was in the same or adjacent anatomical region as the intra-operative result. The present results show that the magnetocardiographic method using a realistic torso model is capable of localizing pre-excitation sites with sufficient accuracy to provide extra information so that non-pharmacological therapeutic interventions can be applied.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lingvay, I., Cohen, R. V., Roux, C. W. L., & Sumithran, P. (2024) · The Lancet · doi:10.1016/s0140-6736(24)01210-8 · Cited by 433
Vascular Compliance and Cardiovascular Disease A Risk Factor or a Marker?
Glasser, S. (1997) · American Journal of Hypertension · doi:10.1016/s0895-7061(97)00311-7 · Cited by 308
Clinical application of magnetocardiography
Fenici, R., Brisinda, D., & Meloni, A. M. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.3.291 · Cited by 174
FENICI, R., NENONEN, J., PESOLA, K., KORHONEN, P., LÖTJÖNEN, J., MÄKIJÄRVI, M., TOIVONEN, L., POUTANEN, V., KETO, P., & KATILA, T. (1999) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1999.tb00602.x · Cited by 29
Self-citationFENICI, R., PESOLA, K., KORHONEN, P., MÄKIJÄRVI, M., NENONEN, J., TOIVONEN, L., FENICI, P., & KATILA, T. (1998) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1998.tb01207.x · Cited by 22
Self-citation
Metadata
- Authors
- NENONEN, J., MAKIJARVI, M., TOIVONEN, L., FORSMAN, K., LEINIO, M., MONTONEN, J., JARVINEN, A., KETO, P., HEKALI, P., KATILA, T., & SILTANEN, P.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 1993-02-02
- Volume
- 14
- Issue
- 2
- Pages
- 168-174
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2033288492
- Cited by
- 32
- References
- 0
- FWCI
- 1.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Non-invasive magnetocardiographic localization of ventricular pre-excitation in the Wolff-Parkinson-White syndrome using a realistic torso model. https://app.cochat.ai/papers/10.1093/eurheartj/14.2.168
- The paper
- NENONEN, J., MAKIJARVI, M., TOIVONEN, L., FORSMAN, K., LEINIO, M., MONTONEN, J., JARVINEN, A., KETO, P., HEKALI, P., KATILA, T., & SILTANEN, P. (1993). Non-invasive magnetocardiographic localization of ventricular pre-excitation in the Wolff-Parkinson-White syndrome using a realistic torso model. European Heart Journal. https://doi.org/10.1093/eurheartj/14.2.168
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.