CoChat

Value, sensitivity and specificity of stroke volume ratio in routine equilibrium gated scintigraphy

Gobert, P., Kremer, R., Rigo, P., Cauwe, F., Chevigne, M. · 1987 · European Heart Journal
Cited by 297

The DOI matches its Crossref record.

Abstract

The stroke volume ratio (SVR) is a new, non invasive method to quantify ventricular volume overload (VVO). We have analyzed its value, sensitivity and specificity in routine clinical practice. The results of 238 consecutive patients (pts) were analysed prospectively within a 3 months period. The SVR was expressed as the ratio of left ventricular (LV) stroke counts over the right ventricular (RV) stroke counts measured on the time-activity curves. One region of interest was drawn per ventricle on the phase and amplitude images. Values above 1.6 were considered as LVVO and below 0.9 as RVVO. Fifty-one patients had VVO due to valvular regurgitation or left-to-right shunt; 187 patients had no evidence of VVO. Mean value obtained for 23 normal subjects with adequate positioning was 1.27 +/- 0.14 (MV +/- SD), ranging from 0.9 to 1.47. Among patients with adequate positioning, no difference was observed in subgroups with dilated cardiopathy (DC) or anteroseptal aneurysm (AA) despite a low EF. MV for patients with LV or RV hypertrophy (H) were statistically different. Sensitivity was 82% for the 51 patients with VVO. False negatives were due to biventricular overload or mild VVO. Specificity evaluated in the 187 patients without VVO was 76%. The 45 false positives were due to poor separation of the right cardiac chambers and/or of the 2 ventricles. They were observed in 4 patients with AA, 3 patients with DC, 7 patients with LVH, 4 patients with RVH and 24 patients with inadequate positioning. No explanation was found in 3 patients. We conclude that cardiac equilibrium blood pool scintigraphy has an adequate sensitivity and specificity to evaluate patients with VVO.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/8.suppl_c.77

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 297

Metadata

Authors
Gobert, P., Kremer, R., Rigo, P., Cauwe, F., & Chevigne, M.
Venue
European Heart Journal
Published
1987-08-02
Volume
8
Issue
suppl C
Pages
77-81
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W1968292753
Cited by
297
References
0
FWCI
42.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Value, sensitivity and specificity of stroke volume ratio in routine equilibrium gated scintigraphy. https://app.cochat.ai/papers/10.1093/eurheartj/8.suppl_c.77
The paper
Gobert, P., Kremer, R., Rigo, P., Cauwe, F., & Chevigne, M. (1987). Value, sensitivity and specificity of stroke volume ratio in routine equilibrium gated scintigraphy. European Heart Journal. https://doi.org/10.1093/eurheartj/8.suppl_c.77

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.