The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A worldwide survey on incidence, management, and prognosis of oesophageal fistula formation following atrial fibrillation catheter ablation: the POTTER-AF study
Open accessAbstract
Aims: Oesophageal fistula represents a rare but dreadful complication of atrial fibrillation catheter ablation. Data on its incidence, management, and outcome are sparse. Methods and results: This international multicentre registry investigates the characteristics of oesophageal fistulae after treatment of atrial fibrillation by catheter ablation. A total of 553 729 catheter ablation procedures (radiofrequency: 62.9%, cryoballoon: 36.2%, other modalities: 0.9%) were performed, at 214 centres in 35 countries. In 78 centres 138 patients [0.025%, radiofrequency: 0.038%, cryoballoon: 0.0015% (P < 0.0001)] were diagnosed with an oesophageal fistula. Peri-procedural data were available for 118 patients (85.5%). Following catheter ablation, the median time to symptoms and the median time to diagnosis were 18 (7.75, 25; range: 0–60) days and 21 (15, 29.5; range: 2–63) days, respectively. The median time from symptom onset to oesophageal fistula diagnosis was 3 (1, 9; range: 0–42) days. The most common initial symptom was fever (59.3%). The diagnosis was established by chest computed tomography in 80.2% of patients. Oesophageal surgery was performed in 47.4% and direct endoscopic treatment in 19.8% and conservative treatment in 32.8% of patients. The overall mortality was 65.8%. Mortality following surgical (51.9%) or endoscopic treatment (56.5%) was significantly lower as compared to conservative management (89.5%) [odds ratio 7.463 (2.414, 23.072) P < 0.001]. Conclusion: Oesophageal fistula after catheter ablation of atrial fibrillation is rare and occurs mostly with the use of radiofrequency energy rather than cryoenergy. Mortality without surgical or endoscopic intervention is exceedingly high.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859116 · Cited by 2,852
Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial Fibrillation
Kuck, K.-H., Brugada, J., Fürnkranz, A., Metzner, A., Ouyang, F., Chun, K. R. J., Elvan, A., Arentz, T., Bestehorn, K., Pocock, S. J., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1602014 · Cited by 1,950
Self-citation
Cited by
Tzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Sepehri Shamloo, A., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Europace · doi:10.1093/europace/euae043 · Cited by 634
Self-citationTzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Shamloo, A. S., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.03.017 · Cited by 298
Self-citation
Metadata
- Authors
- Tilz, R. R., Schmidt, V., Pürerfellner, H., Maury, P., Chun, K. R. J. U., Martinek, M., Sohns, C., Schmidt, B., Mandel, F., Gandjbakhch, E., Laredo, M., Gunawardene, M. A., Willems, S., Beiert, T., Borlich, M., Iden, L., Füting, A., Spittler, R., Gaspar, T., Richter, S., Schade, A., Kuniss, M., Neumann, T., Francke, A., Wunderlich, C., Shin, D.-I., Meininghaus, D. G., Foresti, M., Bonsels, M., Reek, D., Wiegand, U., Bauer, A., Metzner, A., Eckardt, L., Popescu, S. Ș., Krahnefeld, O., Sticherling, C., Kühne, M., Nguyen, D. Q., Roten, L., Saguner, A. M., Linz, D., van der Voort, P., Mulder, B. A., Vijgen, J., Almorad, A., Guenancia, C., Fauchier, L., Boveda, S., Greef, Y. D., Da Costa, A., Jais, P., Derval, N., Milhem, A., Jesel, L., Garcia, R., Poty, H., Khoueiry, Z., Seitz, J., Laborderie, J., Mechulan, A., Brigadeau, F., Zhao, A., Saludas, Y., Piot, O., Ahluwalia, N., Martin, C., Chen, J., Antolic, B., Leventopoulos, G., Özcan, E. E., Yorgun, H., Cay, S., Yalin, K., Botros, M. S., Mahmoud, A. T., Jędrzejczyk-Patej, E., Inaba, O., Okumura, K., Ejima, K., Khakpour, H., Boyle, N., Catanzaro, J. N., Reddy, V., Mohanty, S., Natale, A., Blessberger, H., Yang, B., Stevens, I., Sommer, P., Veltmann, C., Steven, D., Vogler, J., Kuck, K.-H., Merino, J. L., Keelani, A., & Heeger, C.-H.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2023-04-16
- Volume
- 44
- Issue
- 27
- Pages
- 2458-2469
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W4365997996
- Cited by
- 172
- References
- 2
- FWCI
- 30.25
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A worldwide survey on incidence, management, and prognosis of oesophageal fistula formation following atrial fibrillation catheter ablation: the POTTER-AF study. https://app.cochat.ai/papers/10.1093/eurheartj/ehad250
- The paper
- Tilz, R. R., Schmidt, V., Pürerfellner, H., Maury, P., Chun, K. R. J. U., Martinek, M., Sohns, C., Schmidt, B., Mandel, F., Gandjbakhch, E., Laredo, M., Gunawardene, M. A., Willems, S., Beiert, T., Borlich, M., Iden, L., Füting, A., Spittler, R., Gaspar, T., . . . Heeger, C.-H. (2023). A worldwide survey on incidence, management, and prognosis of oesophageal fistula formation following atrial fibrillation catheter ablation: the POTTER-AF study. European Heart Journal. https://doi.org/10.1093/eurheartj/ehad250
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.