Comparative assessment of right, left, and biventricular pacing in patients with permanent atrial fibrillation
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
AIMS: Left ventricular (LV) and biventricular (BiV) pacing are potentially superior to right ventricular (RV) apical pacing in patients undergoing atrioventricular (AV) junction ablation and pacing for permanent atrial fibrillation. METHODS AND RESULTS: Prospective randomized, single-blind, 3-month crossover comparison between RV and LV pacing (phase 1) and between RV and BiV pacing (phase 2) performed in 56 patients (70+/-8 years, 34 males) affected by severely symptomatic permanent atrial fibrillation, uncontrolled ventricular rate, or heart failure. Primary endpoints were quality of life and exercise capacity. Compared with RV pacing, the Minnesota Living with Heart Failure Questionnaire (LHFQ) score improved by 2 and 10% with LV and BiV pacing, respectively, the effort dyspnoea item of the Specific Symptom Scale (SSS) changed by 0 and 2%, the Karolinska score by 6 and 14% (P<0.05 for BiV), the New York Heart Association (NYHA) class by 5 and 11% (P<0.05 for BiV), the 6-min walked distance by 12 (+4%) and 4 m (+1%), and the ejection fraction by 5 and 5% (P<0.05 for both). BiV pacing but not LV pacing was slightly better than RV pacing in the subgroup of patients with preserved systolic function and absence of native left bundle branch block. Compared with pre-ablation measures, the Minnesota LHFQ score improved by 37, 39, and 49% during RV, LV, and BiV pacing, respectively, the effort dyspnoea item of the SSS by 25, 25, and 39%, the Karolinska score by 39, 42, and 54%, the NYHA class by 21, 25, and 30%, the 6-min walking distance by 35 (12%), 47 (16%), and 51 m (19%) and the ejection fraction by 5, 10, and 10% (all differences P<0.05). CONCLUSIONS: Rhythm regularization achieved with AV-junction ablation improved quality of life and exercise capacity with all modes of pacing. LV and BiV pacing provided modest or no additional favourable effect compared with RV pacing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cardiac Resynchronization in Chronic Heart Failure
Abraham, W. T., Fisher, W. G., Smith, A. L., Delurgio, D. B., Leon, A. R., Loh, E., Kocovic, D. Z., Packer, M., Clavell, A. L., Hayes, D. L., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013168 · Cited by 4,648
CARDIAC RESYNCHRONIZATION IN CHRONIC HEART FAILURE
Braham, W. I. T. A., Isher, W. E. G. F., Mith, L. S., Elurgio, D. A. B. D., Eon, A. N. R. L., Oh, E., Ocovic, D. U. Z. K., Acker, M. G., Lavell, L. C., Ayes, D. A. L. H., et al. (2002) · Cited by 3,808
Cazeau, S., Leclercq, C., Lavergne, T., Walker, S., Varma, C., Linde, C., Garrigue, S., Kappenberger, L., Haywood, G. A., Santini, M., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200103223441202 · Cited by 2,751
Young, J. B., Abraham, W. T., & Smith, A. L. (2003) · ACC Current Journal Review · doi:10.1016/j.accreview.2003.08.087 · Cited by 1,682
Nomenclature and Criteria for Diagnosis of Diseases of the Heart and Great Vessels.
(1974) · Annals of Internal Medicine · doi:10.7326/0003-4819-80-5-678_2 · Cited by 1,471
Patients' self-assessment of their congestive heart failure
Ts, R. (1987) · Medical Entomology and Zoology · Cited by 1,028
Hemodynamic Effects of an Irregular Sequence of Ventricular Cycle Lengths During Atrial Fibrillation
Clark, D. M., Plumb, V. J., Epstein, A. E., & Kay, G. N. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00254-4 · Cited by 609
Clinical Outcomes After Ablation and Pacing Therapy for Atrial Fibrillation: A Meta-Analysis
Wood, M. A., Brown-Mahoney, C., Kay, G. N., & Ellenbogen, K. A. (2000) · Circulation · doi:10.1161/01.cir.101.10.1138 · Cited by 476
Leclercq, C. (2002) · European Heart Journal · doi:10.1053/euhj.2002.3232 · Cited by 452
Auricchio, A., Stellbrink, C., Butter, C., Sack, S., Vogt, J., Misier, A. R., Böcker, D., Block, M., Kirkels, J. H., Kramer, A., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.04.003 · Cited by 409
Penicka, M., Bartunek, J., De Bruyne, B., Vanderheyden, M., Goethals, M., De Zutter, M., Brugada, P., & Geelen, P. (2004) · Circulation · doi:10.1161/01.cir.0000116765.43251.d7 · Cited by 405
Cardiac resynchronization in patients with congestive heart failure and chronic atrial fibrillation
Leon, A. R., Greenberg, J. M., Kanuru, N., Baker, C. M., Mera, F. V., Smith, A. L., Langberg, J. J., & DeLurgio, D. B. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01779-5 · Cited by 394
Effect of an irregular ventricular rhythm on cardiac output
Daoud, E. G., Weiss, R., Bahu, M., Knight, B. P., Bogun, F., Goyal, R., Harvey, M., Strickberger, S. A., Man, K. C., & Morady, F. (1996) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)89297-1 · Cited by 361
Brignole, M., Menozzi, C., Gianfranchi, L., Musso, G., Mureddu, R., Bottoni, N., & Lolli, G. (1998) · Circulation · doi:10.1161/01.cir.98.10.953 · Cited by 329
Self-citationPatients' self-assessment of their congestive heart failure
Ts, R. (1987) · Medical Entomology and Zoology · Cited by 251
Fitzpatrick, A. P., Kourouyan, H. D., Siu, A., Lee, R. J., Lesh, M. D., Epstein, L. M., Griffin, J. C., & Scheinman, M. M. (1996) · American Heart Journal · doi:10.1016/s0002-8703(96)90528-1 · Cited by 219
STAMBLER, B. S., ELLENBOGEN, K. A., ZHANG, X., PORTER, T. R., XIE, F., MALIK, R., SMALL, R., BURKE, M., KAPLAN, A., NAIR, L., et al. (2003) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2003.03216.x · Cited by 212
AUSUBEL, K., & FURMAN, S. (1985) · Annals of Internal Medicine · doi:10.7326/0003-4819-103-3-420 · Cited by 211
Brignole, M., Gianfranchi, L., Menozzi, C., Bottoni, N., Bollini, R., Lolli, G., Oddone, D., & Gaggioli, G. (1994) · The American Journal of Cardiology · doi:10.1016/0002-9149(94)90364-6 · Cited by 199
Self-citationRight ventricular pacing reduces the rate of left ventricular relaxation and filling
Zile, M. R., Blaustein, A. S., Shimizu, G., & Gaasch, W. H. (1987) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(87)80215-2 · Cited by 191
Leclercq, C., Víctor, F., Alonso, C., Pavin, D., d’Allones, G. R., Bansard, J., Mabo, P., & Daubert, C. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)00716-5 · Cited by 144
Rosenqvist, M., Lee, M. A., Moulinier, L., Springer, M. J., Abbott, J. A., Wu, J. T., Langberg, J. J., Griffin, J. C., & Scheinman, M. M. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90394-5 · Cited by 132
Gosselink, A. T. M., Blanksma, P. K., Crijns, H. J. G. M., Gelder, I. C. V., de Kam, P., Hillege, H. L., Niemeijer, M. G., Lie, K. I., & MEIJLER, F. L. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00340-1 · Cited by 110
LINDE‐EDELSTAM, C., Nordlander, R., Undén, A., Orth‐Gomér, K., & Rydén, L. (1992) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1992.tb02920.x · Cited by 91
Opasich, C., Pinna, G. D., Mazza, A., Febo, O., Riccardi, P. G., Capomolla, S., Cobelli, F., & Tavazzi, L. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00218-5 · Cited by 75
Puggioni, E., Brignole, M., GAMMAGE, M. D., Soldati, E., Bongiorni, M. G., SIMANTIRAKIS, E. N., Vardas, P. E., Gadler, F., Bergfeldt, L., Tomasi, C., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.09.027 · Cited by 68
Self-citationCardiac output and the varying R-R interval of atrial fibrillation
Herbert, W. H. (1973) · Journal of Electrocardiology · doi:10.1016/s0022-0736(73)80006-8 · Cited by 40
Cited by
2013 ACCF/AHA Guideline for the Management of Heart Failure
Yancy, C. W., Jessup, M., Bozkurt, B., Butler, J., Casey, D. E., Drazner, M. H., Fonarow, G. C., Geraci, S. A., Horwich, T., Januzzi, J. L., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.05.019 · Cited by 12,536
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000041 · Cited by 7,115
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001063 · Cited by 4,922
Yancy, C. W., Jessup, M., Bozkurt, B., Butler, J., Casey, D. E., Drazner, M. H., Fonarow, G. C., Geraci, S. A., Horwich, T., Januzzi, J. L., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31829e8807 · Cited by 3,304
2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.03.022 · Cited by 2,955
Metadata
- Authors
- Brignole, M., Gammage, M., Puggioni, E., Alboni, P., Raviele, A., Sutton, R., Vardas, P., Bongiorni, M. G., Bergfeldt, L., Menozzi, C., & Musso, G.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-12-20
- Volume
- 26
- Issue
- 7
- Pages
- 712-722
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2150420946
- Cited by
- 198
- References
- 27
- FWCI
- 8.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.