The DOI matches its Crossref record.
Results and mid–long-term follow-up of stent implantation for native and recurrent coarctation of the aorta
Abstract
AIMS: Since the late 1980s, endovascular stents have been used in the treatment of several vascular lesions. In the last decades, stent implantation has been proposed as a reliable option for the treatment of coarctation of the aorta. In this setting, it seems to have some advantages, rendering it superior to angioplasty alone. METHODS AND RESULTS: Between December 1997 and December 2004, 71 consecutive patients (44 males and 27 females) underwent cardiac catheterization for native or recurrent coarctation of the aorta. Seventy-four stents were implanted. All discharged patients were enrolled in a follow-up programme. Every patient underwent clinical evaluation, echo-colour Doppler studies, and exercise ECG at 1 and 6 months after the stent implantation. Peak systolic gradient dropped from 39.3 +/- 15.3 to 3.6 +/- 5.5 mmHg (P = 0.0041). The diameter of the coarcted segment increased from 8.3 +/- 2.9 to 16.4 +/- 3.8 mm (P = 0.037). In our series, one death occurred in a 22-year-old girl with a recurrent coarctation of the aorta, just after stent implantation. The rate of minor complications was <2%. Re-dilatation of a previously implanted stent was performed in three patients. CONCLUSION: In our experience (the largest reported to the best of our knowledge), stenting of a coarctation/re-coarctation of the aorta represents a safe alternative treatment without a significant mid-long-term complication.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Warnes, C. A., Williams, R. G., Bashore, T. M., Child, J. S., Connolly, H. M., Dearani, J. A., del Nido, P., Fasules, J. W., Graham, T. P., Hijazi, Z. M., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.190811 · Cited by 2,066
Stout, K. K., Daniels, C. J., Aboulhosn, J. A., Bozkurt, B., Broberg, C. S., Colman, J. M., Crumb, S. R., Dearani, J. A., Fuller, S., Gurvitz, M., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000603 · Cited by 1,602
2018 AHA/ACC Guideline for the Management of Adults With Congenital Heart Disease
Stout, K. K., Daniels, C. J., Aboulhosn, J. A., Bozkurt, B., Broberg, C. S., Colman, J. M., Crumb, S. R., Dearani, J. A., Fuller, S., Gurvitz, M., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.08.1029 · Cited by 1,080
Stout, K. K., Daniels, C. J., Aboulhosn, J. A., Bozkurt, B., Broberg, C. S., Colman, J. M., Crumb, S. R., Dearani, J. A., Fuller, S., Gurvitz, M., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000602 · Cited by 533
Metadata
- Authors
- Chessa, M., Carrozza, M., Butera, G., Piazza, L., Negura, D. G., Bussadori, C., Bossone, E., Giamberti, A., & Carminati, M.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-09-26
- Volume
- 26
- Issue
- 24
- Pages
- 2728-2732
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2115676512
- Cited by
- 172
- References
- 0
- FWCI
- 6.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Results and mid–long-term follow-up of stent implantation for native and recurrent coarctation of the aorta. https://app.cochat.ai/papers/10.1093/eurheartj/ehi491
- The paper
- Chessa, M., Carrozza, M., Butera, G., Piazza, L., Negura, D. G., Bussadori, C., Bossone, E., Giamberti, A., & Carminati, M. (2005). Results and mid–long-term follow-up of stent implantation for native and recurrent coarctation of the aorta. European Heart Journal. https://doi.org/10.1093/eurheartj/ehi491
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.