Cost-effectiveness of neonatal ECG screening for the long QT syndrome
The DOI matches its Crossref record.
Abstract
AIMS: A significant number of preventable cardiac deaths in infancy and childhood are due to long QT syndrome (LQTS) and to unrecognized neonatal congenital heart diseases (CHDs). Both carry a serious risk for avoidable mortality and morbidity but effective treatments exist to prevent lethal arrhythmias or to allow early surgical correction before death or irreversible cardiac damage. As an electrocardiogram (ECG) allows recognition of LQTS and of some of the CHDs that have escaped medical diagnosis, and as LQTS also contributes to sudden infant death syndrome, we have analysed the cost-effectiveness of a nationwide programme of neonatal ECG screening. Our primary analysis focused on LQTS alone; a secondary analysis focused on the possibility of identifying some CHDs also. METHODS AND RESULTS: A decision analysis approach was used, building a decision tree for the strategies 'screening'-'no screening'. Markov processes were used to simulate the natural or clinical histories of the patients. To assess the impact of potential errors in the estimates of the model parameters, a Monte Carlo sensitivity analysis was performed by varying all baseline values by +/-30%. Incremental cost-effectiveness analysis for the primary analysis shows that with the screening programme, the cost per year of life saved is very low: 11,740 euro. The cost for saving one entire life of 70 years would be 820,000 euro. Even by varying model parameters by +/-30%, the cost per year of life saved remains between 7400 euro and 20,400 euro. These figures define 'highly cost-effective' screening programmes. The secondary analysis provides even more cost-effective results. CONCLUSION: A programme of neonatal ECG screening performed in a large European country is cost-effective. An ECG performed in the first month of life will allow the early identification of still asymptomatic infants with LQTS and also of infants with some correctable CHDs not recognized by routine neonatal examinations. Appropriate therapy will prevent unnecessary deaths in infants, children, and young adults.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Prevalence of Long-QT Syndrome Gene Variants in Sudden Infant Death Syndrome
Arnestad, M., Crotti, L., Rognum, T. O., Insolia, R., Pedrazzini, M., Ferrandi, C., Vege, A., Wang, D. W., Rhodes, T. E., George, A. L., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.658021 · Cited by 549
The long QT syndrome: a transatlantic clinical approach to diagnosis and therapy
Schwartz, P. J., & Ackerman, M. J. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht089 · Cited by 362
Crotti, L., Celano, G., Dagradi, F., & Schwartz, P. J. (2008) · Orphanet Journal of Rare Diseases · doi:10.1186/1750-1172-3-18 · Cited by 297
Vetter, V. L., Elia, J., Erickson, C., Berger, S., Blum, N., Uzark, K., & Webb, C. L. (2008) · Circulation · doi:10.1161/circulationaha.107.189473 · Cited by 296
Pre-participation screening of young competitive athletes for prevention of sudden cardiac death
Corrado, D., Basso, C., Schiavon, M., Pelliccia, A., & Thiene, G. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.06.053 · Cited by 288
Wheeler, M. T., Heidenreich, P. A., Froelicher, V. F., Hlatky, M. A., & Ashley, E. A. (2010) · Annals of Internal Medicine · doi:10.7326/0003-4819-152-5-201003020-00005 · Cited by 261
Johnson, J. N., & Ackerman, M. J. (2009) · British Journal of Sports Medicine · doi:10.1136/bjsm.2008.054734 · Cited by 229
“depicts the critical importance of context in the determination of when “long is too long”. There would be little debate as to the near-100% pretest probability of LQTS for someone with documented torsades de pointes while swimming and a QTc of 500 ms. On the other hand, there would be tremendous debate as to the prob…”
BackgroundVan Driest, S. L., Wells, Q. S., Stallings, S., Bush, W. S., Gordon, A., Nickerson, D. A., Kim, J. H., Crosslin, D. R., Jarvik, G. P., Carrell, D. S., et al. (2016) · JAMA · doi:10.1001/jama.2015.17701 · Cited by 170
“of ECGs per individual, median (range) 3 (1-14) 3 (1-31) .”
Sudden Cardiac Death in the Young
Ackerman, M., Atkins, D. L., & Triedman, J. K. (2016) · Circulation · doi:10.1161/circulationaha.115.020254 · Cited by 165
A cost-effectiveness analysis of screening for silent atrial fibrillation after ischaemic stroke
Levin, L.-A., Husberg, M., Sobocinski, P. D., Kull, V. F., Friberg, L., Rosenqvist, M., & Davidson, T. (2015) · Europace · doi:10.1093/europace/euu213 · Cited by 56
Metadata
- Authors
- Quaglini, S.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-08-01
- Volume
- 27
- Issue
- 15
- Pages
- 1824-1832
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W4248587493
- Cited by
- 121
- References
- 0
- FWCI
- 8.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.