Electrical storm in patients with an implantable defibrillator: incidence, features, and preventive therapy: insights from a randomized trial
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
AIMS: The purpose of this study was to assess the incidence, features, and clinical sequelae of 'electrical storm' (ES). METHODS AND RESULTS: This study is a prospectively designed secondary analysis of SHIELD; a randomized trial of azimilide for suppression of ventricular tachycardia/fibrillation (VT/VF) leading to implanted cardioverter defibrillator (ICD) therapies. Systematic and rigorous follow-up and blinded adjudication of ICD therapy allowed identification of all ESs (>/=3 separate VT/VF episodes leading to ICD therapies within 24 h). Of 633 ICD recipients, 148 (23%) experienced at least one ES over 1-year follow-up. No clinical predictors of ES were identified. Frequent VT episodes accounted for 91% of all ESs, with the remaining being VF alone or both VT plus VF. ES led to a 3.1-fold increase in arrhythmia-related hospitalization (95% CI 2.3-4.3; P<0.0001) compared with patients with isolated VT/VF, and to a 10.2-fold increase (95% CI 6.4-16.3; P<0.0001) compared with patients without VT/VF. Compared with placebo, azimilide (75 and 125 mg/day) reduced the risk of recurrent ES by 37% (HR=0.63, 95% CI 0.35-1.11, P=0.11) and 55% (HR=0.45, 95% CI 0.23-0.87, P=0.018), respectively. However, the reduction in time-to-first ES did not reach statistical significance by both doses (75 and 125 mg) of azimilide (HR=0.82, 95% CI 0.56-1.19, P=0.29 and HR=0.69, 95% CI 0.46-1.04, P=0.07), respectively. CONCLUSION: ES is common and unpredictable in ICD recipients and it is a strong predictor of hospitalization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moss, A. J., Zareba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,902
Cox’s regression model for counting processes: A large sample study
Andersen, P. K., & Gill, R. D. (1982) · The Annals of Statistics · doi:10.1214/aos/1176345976 · Cited by 4,419
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
Meta-analysis of the implantable cardioverter defibrillator secondary prevention trials
Connolly, S. (2000) · European Heart Journal · doi:10.1053/euhj.2000.2476 · Cited by 1,126
Semiparametric regression for the mean and rate functions of recurrent events
Lin, D. Y., Wei, L. J., Yang, I., & Ying, Z. (2000) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/1467-9868.00259 · Cited by 969 · cited 2×
“Age (mean+ SD years) 62 (11) 64 (11) 63 (13) 0.27 Female, n (%) 12 (8) 22 (9) 30 ( 12 ) 0.41 Ischaemic heart disease, n (%) 105 (71) 156 (66) 177 (71) 0.50 Valvular disease, n (%) 58 (39) 121 (51) 90 (36) 0.002 Previous MI, n (%) 95 (64) 150 (64) 161 (64) 0.99 Congestive heart failure, n (%) 102 (69) 176 (75) 157 (63)…”
InfluentialTreating Electrical Storm: Sympathetic Blockade Versus Advanced Cardiac Life Support–Guided Therapy
Nademanee, K., Taylor, R., Bailey, W. E., Rieders, D. E., & Kosar, E. M. (2000) · Circulation · doi:10.1161/01.cir.102.7.742 · Cited by 504
Exner, D. V., Pinski, S. L., Wyse, D. G., Renfroe, E. G., Follmann, D., Gold, M., Beckman, K. J., Coromilas, J., Lancaster, S., & Hallstrom, A. P. (2001) · Circulation · doi:10.1161/01.cir.103.16.2066 · Cited by 396 · cited 8×
“Data obtained from prospective randomized studies, in particular, are very sparse.(7) The SHock Inhibition Evaluation with AzimiLiDe (SHIELD) trial was a double-blind, placebo-controlled randomized trial evaluating the effects of azimilide, a novel class III antiarrhythmic drug, on the frequency of device therapies in…”
BackgroundMethodResultInfluentialElectrical storm in patients with transvenous implantable cardioverter-defibrillators
Credner, S. C., Klingenheben, T., Mauss, O., Sticherling, C., & Hohnloser, S. H. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00495-1 · Cited by 376 · cited 1×
“Lower LVEF in patients with ES compared with ICD recipients without device therapy was also described in some reports,(7) but not in others.(5) Our results, in one of the largest series of ES patients studied, demonstrate that LV function in storm patients was slightly but significantly better than that of patients wi…”
ResultSelf-citationQuality of life in the Canadian Implantable Defibrillator Study (CIDS)
Irvine, J., Dorian, P., Baker, B., O'Brien, B. J., Roberts, R., Gent, M., Newman, D., & Connolly, S. J. (2002) · American Heart Journal · doi:10.1067/mhj.2002.124049 · Cited by 368 · cited 1×
“Multiple shocks produce profound psychological morbidity, resulting in severely impaired quality of life.(9) Moreover, there is evidence that ES may be a harbinger of increased mortality.”
BackgroundSelf-citationImplantable Cardioverter–Defibrillators
DiMarco, J. P. (2003) · New England Journal of Medicine · doi:10.1056/nejmra035432 · Cited by 290
Verma, A., Kılıçaslan, F., Marrouche, N. F., Minor, S., Khan, M., Wazni, O. M., Burkhardt, J. D., Belden, W. A., Cummings, J. E., Abdul‐Karim, A., et al. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.04352.x · Cited by 162 · cited 1×
“Identifiable causes such as congestive heart failure (31%) or electrolyte disorders (20%) were reported in some studies.(16) However, in the majority of events, no ‘triggers’ were found.”
BackgroundSelf-citationDorian, P., Borggrefe, M., Al-Khalidi, H. R., Hohnloser, S. H., Brum, J. M., Tatla, D. S., Brachmann, J., Myerburg, R. J., Cannom, D. S., van der Laan, M., et al. (2004) · Circulation · doi:10.1161/01.cir.0000149240.98971.a8 · Cited by 155
Self-citationBänsch, D., Böcker, D., Brunn, J., Weber, M., BREITHARDT, G. E., & Block, M. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00726-9 · Cited by 146
Greene, M. (2000) · Europace · doi:10.1053/eupc.2000.0104 · Cited by 140
Robust Tests for Treatment Comparisons Based on Recurrent Event Responses
Cook, R. J., Lawless, J. F., & Nadeau, C. (1996) · Biometrics · doi:10.2307/2532895 · Cited by 92
Azimilide Dihydrochloride, a Novel Antiarrhythmic Agent
Karam, R., Marcello, S. R., Brooks, R. R., Corey, A. E., & Moore, A. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00152-0 · Cited by 70 · cited 1×
“Azimilide dihydrochloride is an investigational antiarrhythmic drug with potassium channel (IKr and IKs) blocking properties, which prolongs the cardiac action potential and refractory periods.(10,11) Randomization was conducted in a ratio of 1:1:1 to placebo or two doses of azimilide (75 or 125 mg once daily).”
BackgroundEmergencies related to implantable cardioverter-defibrillators
Pinski, S. L. (2000) · Critical Care Medicine · doi:10.1097/00003246-200010001-00011 · Cited by 38 · cited 1×
“three or more VT/VF episodes within 24 h) has been defined as an electrical storm (ES) and constitutes a medical emergency.(8) Multiple shocks produce profound psychological morbidity, resulting in severely impaired quality of life.”
Background
Cited by
2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2019) · EP Europace · doi:10.1093/europace/euz132 · Cited by 475
Carbucicchio, C., Santamaria, M., Trevisi, N., Maccabelli, G., Giraldi, F., Fassini, G., Riva, S., Moltrasio, M., Cireddu, M., Veglia, F., et al. (2008) · Circulation · doi:10.1161/circulationaha.106.686534 · Cited by 460
2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2019.03.002 · Cited by 431
Di Biase, L., Santangeli, P., Burkhardt, D. J., Bai, R., Mohanty, P., Carbucicchio, C., Dello Russo, A., Casella, M., Mohanty, S., Pump, A., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.03.044 · Cited by 422
EHRA/HRS/APHRS expert consensus on ventricular arrhythmias
Pedersen, C. T., Kay, G. N., Kalman, J., Borggrefe, M., Della-Bella, P., Dickfeld, T., Dorian, P., Huikuri, H., Kim, Y.-H., Knight, B., et al. (2014) · Europace · doi:10.1093/europace/euu194 · Cited by 327
Self-citation
Metadata
- Authors
- Hohnloser, S. H., Al-Khalidi, H. R., Pratt, C. M., Brum, J. M., Tatla, D. S., Tchou, P., Dorian, P., & on behalf of the SHock Inhibition Evaluation with AzimiLiDe (SHIELD) Investigators
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-04-07
- Volume
- 27
- Issue
- 24
- Pages
- 3027-3032
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2115951287
- Cited by
- 193
- References
- 17
- FWCI
- 5.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.