CoChat

Outcome of implantable cardioverter defibrillators in adults with congenital heart disease: a multi-centre study

Open access
Yap, Sing-Chien, Roos-Hesselink, Jolien W., Hoendermis, Elke S., Budts, Werner, Vliegen, Hubert W., Mulder, Barbara J.M., van Dijk, Arie P.J., Schalij, Martin J., Drenthen, Willem · 2007 · European Heart Journal
Cited by 112

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

AIMS: To investigate outcome and complications of implantable cardioverter defibrillators (ICDs) in adults with congenital heart disease (CHD) and to identify predictors of (in-) appropriate shocks. METHODS AND RESULTS: Sixty-four CHD patients >/= 18 years at first ICD implantation [63% tetralogy of Fallot (TOF) and age at implantation 37 +/- 13 years] were identified using the Dutch adult CHD registry and a Belgian tertiary care centre database. Median follow-up duration was 3.7 years. Early complications included pocket haematoma (n = 3), lead failure (n = 2), and pneumothorax (n = 2). Late complications occurred in 11 (17%) patients, including lead failure (n = 6) and and electrical storm (n = 3). Overall, 30 device-related re-interventions were performed in 20 patients (31%), including four premature generator changes and seven lead replacements. Half of the patients received one or more shocks, and 46 shocks in 15 patients (23%) were classified as appropriate. One hundred and sixty shocks in 26 patients (41%) were classified as inappropriate. No predictors of (in-)appropriate shocks were identified, except TOF being associated with less appropriate shocks than patients with other CHD (HR 0.29, P = 0.02). CONCLUSION: The ICD provided effective therapy in a quarter of adults with CHD with low complication rates. The incidence of inappropriate shocks, however, appeared to be excessive and warrants further attention.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehl306

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 112

Metadata

Authors
Yap, S.-C., Roos-Hesselink, J. W., Hoendermis, E. S., Budts, W., Vliegen, H. W., Mulder, B. J. M., van Dijk, A. P. J., Schalij, M. J., & Drenthen, W.
Venue
European Heart Journal
Published
2006-10-09
Volume
28
Issue
15
Pages
1854-1861
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2112816694
Cited by
112
References
3
FWCI
3.72
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Outcome of implantable cardioverter defibrillators in adults with congenital heart disease: a multi-centre study. https://app.cochat.ai/papers/10.1093/eurheartj/ehl306
The paper
Yap, S.-C., Roos-Hesselink, J. W., Hoendermis, E. S., Budts, W., Vliegen, H. W., Mulder, B. J. M., van Dijk, A. P. J., Schalij, M. J., & Drenthen, W. (2007). Outcome of implantable cardioverter defibrillators in adults with congenital heart disease: a multi-centre study. European Heart Journal. https://doi.org/10.1093/eurheartj/ehl306

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.