The long-term cost-effectiveness of cardiac resynchronization therapy with or without an implantable cardioverter-defibrillator
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
AIMS: Cardiac resynchronization therapy (CRT-P) is an effective treatment for patients with heart failure and cardiac dyssynchrony with moderate or severe symptoms despite pharmacological therapy. The addition of an implantable cardioverter-defibrillator (ICD) function may further reduce the risk of sudden death. We assessed the cost-effectiveness of CRT-P compared with medical therapy (MT) alone, and the cost-effectiveness of CRT-ICD + MT compared with CRT-P + MT, on incremental cost per quality adjusted life year (QALY) and life year using data from two landmark clinical trials. METHODS AND RESULTS: A Markov model with Monte Carlo simulation to assess costs, life years, and QALYs associated with CRT (+/- ICD) and MT in patients with heart failure and cardiac dyssynchrony, on the basis of a UK healthcare perspective was constructed. NYHA class distribution and transitions, associated health utilities, rates and cause of hospitalization and death were estimated from individual patient data from the CArdiac REsychronization in Heart Failure (CARE-HF trial). The estimated additional benefit on survival of an ICD was based on results from COMPANION. The base case analysis used 10 000 individual life-time simulations assuming a battery life of 6 years for CRT-P and 7 years for CRT-ICD. From a life-time perspective in a 65-year-old patient, the incremental cost-effectiveness of CRT-P compared with MT is 7538 euros (95% CI 5325-11,784 euros) per QALY gained and 7011euros (95% CI 5346-10,003 euros) per life year gained. The incremental cost-effectiveness of CRT-ICD compared with CRT-P is 47,909 euros (95% CI 35,703-79,438 euros) per QALY gained, and 35,864 euros (95% CI 26,709-56,353 euros) per life year gained. CONCLUSION: Long-term treatment with CRT-P appears cost-effective compared with MT alone. From a life-time perspective, assuming a reasonable life expectancy when receiving effective treatment for heart failure, CRT-ICD may also be considered cost-effective when compared with CRT-P + MT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Effect of Cardiac Resynchronization on Morbidity and Mortality in Heart Failure
Cleland, J. G. F., Daubert, J.-C., Erdmann, E., Freemantle, N., Gras, D., Kappenberger, L., & Tavazzi, L. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa050496 · Cited by 6,276
Self-citationBristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., DeMets, D., White, B. G., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032423 · Cited by 5,812
Cardiac Resynchronization in Chronic Heart Failure
Abraham, W. T., Fisher, W. G., Smith, A. L., Delurgio, D. B., Leon, A. R., Loh, E., Kocovic, D. Z., Packer, M., Clavell, A. L., Hayes, D. L., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013168 · Cited by 4,648
CARDIAC RESYNCHRONIZATION IN CHRONIC HEART FAILURE
Braham, W. I. T. A., Isher, W. E. G. F., Mith, L. S., Elurgio, D. A. B. D., Eon, A. N. R. L., Oh, E., Ocovic, D. U. Z. K., Acker, M. G., Lavell, L. C., Ayes, D. A. L. H., et al. (2002) · Cited by 3,808
Cazeau, S., Leclercq, C., Lavergne, T., Walker, S., Varma, C., Linde, C., Garrigue, S., Kappenberger, L., Haywood, G. A., Santini, M., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200103223441202 · Cited by 2,751
Self-citationYoung, J. B., Abraham, W. T., & Smith, A. L. (2003) · ACC Current Journal Review · doi:10.1016/j.accreview.2003.08.087 · Cited by 1,682
Handling Uncertainty in Cost-Effectiveness Models
Briggs, A. H. (2000) · PharmacoEconomics · doi:10.2165/00019053-200017050-00006 · Cited by 807
National Institute for Clinical Excellence and its value judgments
Rawlins, M. D., & Culyer, A. J. (2004) · BMJ · doi:10.1136/bmj.329.7459.224 · Cited by 765 · cited 2×
“40 of being costeffective compared with CRT-Pþ MT treatment alone.(18) Analyses by cohort age”
MethodResultPacemaker and ICD Generator Malfunctions: Analysis of Food and Drug Administration Annual Reports
Maisel, W. H., Moynahan, M., Zuckerman, B. D., Gross, T. P., Tovar, O. H., Tillman, D.-B., & Schultz, D. B. (2006) · JAMA · doi:10.1001/jama.295.16.1901 · Cited by 353
Gould, P. A. (2006) · JAMA · doi:10.1001/jama.295.16.1907 · Cited by 288 · cited 1×
“However, the device longevity for the CRT–ICD device also assumed an energy conserving programming specification, which may not be used routinely in practice, and the device longevity we assumed in the base case may not be achieved in practice.(19,20) Longer battery life clearly results in an increased cost-effectiven…”
BackgroundMode of Death in Advanced Heart Failure
Carson, P., Anand, I., O’Connor, C., Jaski, B., Steinberg, J., Lwin, A., Lindenfeld, J., Ghali, J., Barnet, J. H., Feldman, A. M., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.09.016 · Cited by 228
The Effect of Cardiac Resynchronization on Morbidity and Mortality in Heart Failure
Cleland, J. G. F., Daubert, J. C., & Erdmann, E. (2005) · ACC Current Journal Review · doi:10.1016/j.accreview.2005.05.046 · Cited by 227
Self-citationFreemantle, N., Tharmanathan, P., Calvert, M. J., Abraham, W. T., Ghosh, J., & Cleland, J. G. F. (2006) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2005.11.014 · Cited by 193
Self-citationFeldman, A. M., de Lissovoy, G., Bristow, M. R., Saxon, L. A., De Marco, T., Kass, D. A., Boehmer, J., Singh, S., Whellan, D. J., Carson, P., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.08.033 · Cited by 184
Cost-effectiveness of cardiac resynchronization therapy: results from the CARE-HF trial
Calvert, M., Freemantle, N., Yao, G., Cleland, J. G. F., Billingham, L. J., Daubert, J., & Bryan, S. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi662 · Cited by 147
Self-citationCazeau, S., Leclercq, C., & Lavergne, T. (2001) · ACC Current Journal Review · doi:10.1016/s1062-1458(01)00399-3 · Cited by 118
Financial Aspects of Heart Failure Programs of Care
Stewart, S. (2005) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2005.01.001 · Cited by 117
Cost-Effectiveness of Cardiac Resynchronization Therapy in Patients with Symptomatic Heart Failure
Nichol, G., Kaul, P., Huszti, E., & Bridges, J. F. P. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-141-5-200409070-00102 · Cited by 114
Resynchronizing Ventricular Contraction in Heart Failure
Jarcho, J. A. (2005) · New England Journal of Medicine · doi:10.1056/nejme058065 · Cited by 46
Banz, K. (2005) · Value in Health · doi:10.1111/j.1524-4733.2005.03092.x · Cited by 38
Economic Modelling in Drug Reimbursement
Salkeld, G. P., Freemantle, N., & OʼBrien, B. J. (2004) · Wiley eBooks · doi:10.1002/9780470994719.ch6 · Cited by 2 · cited 1×
“In the absence of evidence from a definitive trial comparing CRT-P and CRT–ICD, economic modelling provides one useful perspective to health policy decisions.(22) Our analysis indicates that CRT–ICD is cost-effective compared with CRT-P for patients with a reasonable life expectancy (when treated).”
BackgroundSelf-citation
Cited by
Authors/Task Force Members, Vardas, P. E., Auricchio, A., Blanc, J.-J., Daubert, J.-C., Drexler, H., Ector, H., Gasparini, M., Linde, C., Morgado, F. B., et al. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm305 · Cited by 902
Self-citationMcAlister, F. A., Ezekowitz, J., Hooton, N., Vandermeer, B., Spooner, C., Dryden, D. M., Page, R. L., Hlatky, M. A., & Rowe, B. H. (2007) · JAMA · doi:10.1001/jama.297.22.2502 · Cited by 569
Daubert, J.-C., Saxon, L., Adamson, P. B., Auricchio, A., Berger, R. D., Beshai, J. F., Breithard, O., Brignole, M., Cleland, J., DeLurgio, D. B., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.07.025 · Cited by 467
Self-citationMetra, M., Ponikowski, P., Dickstein, K., McMurray, J. J. V., Gavazzi, A., Bergh, C.-H., Fraser, A. G., Jaarsma, T., Pitsis, A., Mohacsi, P., et al. (2007) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2007.04.003 · Cited by 395
Avoiding non-responders to cardiac resynchronization therapy: a practical guide
Daubert, C., Behar, N., Martins, R. P., Mabo, P., & Leclercq, C. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw270 · Cited by 311
Metadata
- Authors
- Yao, G., Freemantle, N., Calvert, M. J., Bryan, S., Daubert, J.-C., & Cleland, J. G. F.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-06-13
- Volume
- 28
- Issue
- 1
- Pages
- 42-51
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2032220099
- Cited by
- 190
- References
- 21
- FWCI
- 9.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.