CoChat

Safety of percutaneous coronary intervention during uninterrupted oral anticoagulant treatment

Karjalainen, P. P., Vikman, S., Niemela, M., Porela, P., Ylitalo, A., Vaittinen, M.-A., Puurunen, M., Airaksinen, T. J., Nyman, K., Vahlberg, T., Airaksinen, K.E. J. · 2008 · European Heart Journal
Cited by 109

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

AIMS: Uninterrupted anticoagulation (UAC) is assumed to increase bleeding and access-site complications. A common consensus is to postpone percutaneous coronary interventions (PCI) to reach international normalized ratio (INR) levels < 1.5-1.8. METHODS AND RESULTS: To assess the safety and feasibility of UAC, we analysed retrospectively all consecutive patients (n = 523) on warfarin therapy referred for PCI in four centres with a policy to interrupt anticoagulation (IAC) before PCI and in three centres with a long experience on UAC during PCI. Major bleeding, access-site complications, and major adverse cardiac events (death, myocardial infarction, target vessel revascularization, and stent thrombosis) were recorded during hospitalization. In the IAC group, warfarin was withdrawn for a mean of 3 days prior to PCI (mean INR 1.7). In the UAC group, mean INR value was 2.2. Glycoprotein IIb/IIIa (GP) inhibitors (P < 0.001) and low-molecular-weight heparins (P < 0.001) were more often used in the IAC group. Major bleeding and access-site complications were more common in the IAC group (5.0% vs. 1.2%, P = 0.02 and 11.3% vs. 5.0%, P = 0.01, respectively) than in the UAC group. After adjusting for propensity score, the group difference in access-site complications remained significant [OR (odds ratio) 2.8, 95% CI (confidence interval) 1.3-6.1, P = 0.008], but did not remain significant in major bleeding (OR 3.9, 95% CI 1.0-15.3, P = 0.05). In multivariable analysis, femoral access (OR 9.9, 95% CI 1.3-75.2), use of access-site closure devices (OR 2.1, 95% CI 1.1-4.0), low-molecular-weight heparin (OR 2.7, 95% CI 1.1-6.7) and old age predicted access-site complications, and the use of GP inhibitors (OR 3.0, 95% CI 1.0-9.1) remained as a predictor of major bleeding. CONCLUSION: Our study shows that PCI is a safe procedure during UAC with no excess bleeding complications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehn099

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 109

Metadata

Authors
Karjalainen, P. P., Vikman, S., Niemela, M., Porela, P., Ylitalo, A., Vaittinen, M.-A., Puurunen, M., Airaksinen, T. J., Nyman, K., Vahlberg, T., & Airaksinen, K. E. J.
Venue
European Heart Journal
Published
2008-03-16
Volume
29
Issue
8
Pages
1001-1010
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2142449187
Cited by
109
References
2
FWCI
7.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Safety of percutaneous coronary intervention during uninterrupted oral anticoagulant treatment. https://app.cochat.ai/papers/10.1093/eurheartj/ehn099
The paper
Karjalainen, P. P., Vikman, S., Niemela, M., Porela, P., Ylitalo, A., Vaittinen, M.-A., Puurunen, M., Airaksinen, T. J., Nyman, K., Vahlberg, T., & Airaksinen, K. E. J. (2008). Safety of percutaneous coronary intervention during uninterrupted oral anticoagulant treatment. European Heart Journal. https://doi.org/10.1093/eurheartj/ehn099

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.