Cited by 261

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Role of adjunctive thrombectomy and embolic protection devices in acute myocardial infarction: a comprehensive meta-analysis of randomized trials

Bavry, A. A., Kumbhani, D. J., Bhatt, D. L.·2008·European Heart Journal

Abstract

AIMS: Adjunctive thrombectomy and embolic protection devices in acute myocardial infarction have been extensively studied, although outcomes have mainly focused on surrogate markers of reperfusion. Therefore, the effect of adjunctive devices on clinical outcomes is unknown. This study sought to determine whether the use of a thrombectomy or embolic protection device during revascularization for acute myocardial infarction reduces mortality compared with percutaneous coronary intervention (PCI) alone. METHODS AND RESULTS: The Cochrane and Medline databases were searched for clinical trials that randomized patients with ST-elevation acute myocardial infarction to an adjuvant device prior to PCI compared with PCI alone. Devices were grouped into catheter thrombus aspiration, mechanical thrombectomy, and embolic protection. There were a total of 30 studies with 6415 patients who met our selection criteria. Over a weighted mean follow-up of 5.0 months, the incidence of mortality among all studies was 3.2% for the adjunctive device group vs. 3.7% for PCI alone (relative risk, 0.87; 95% confidence interval, 0.67-1.13). Among thrombus aspiration studies, mortality was 2.7% for the adjunctive device group vs. 4.4% for PCI alone (P = 0.018), for mechanical thrombectomy, mortality was 5.3% for the adjunctive device group vs. 2.8% for PCI alone (P = 0.050), and for embolic protection, mortality was 3.1% for the adjunctive device group vs. 3.4% for PCI alone (P = 0.69). CONCLUSION: Catheter thrombus aspiration during acute myocardial infarction is beneficial in reducing mortality compared with PCI alone. Mechanical thrombectomy appears to increase mortality, whereas embolic protection appears to have a neutral effect.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehn421

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 261

Metadata

Authors
Bavry, A. A., Kumbhani, D. J., & Bhatt, D. L.
Venue
European Heart Journal
Published
2008-09-23
Volume
29
Issue
24
Pages
2989-3001
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2158789321
Cited by
261
References
2
FWCI
3.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Role of adjunctive thrombectomy and embolic protection devices in acute myocardial infarction: a comprehensive meta-analysis of randomized trials. https://app.cochat.ai/papers/10.1093/eurheartj/ehn421
The paper
Bavry, A. A., Kumbhani, D. J., & Bhatt, D. L. (2008). Role of adjunctive thrombectomy and embolic protection devices in acute myocardial infarction: a comprehensive meta-analysis of randomized trials. European Heart Journal. https://doi.org/10.1093/eurheartj/ehn421

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.