Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 210

The DOI matches its Crossref record.

Overestimation of aortic valve replacement risk by EuroSCORE: implications for percutaneous valve replacement

Open access
Osswald, B. R., Gegouskov, V., Badowski-Zyla, D., Tochtermann, U., Thomas, G., Hagl, S., Blackstone, E. H.·2008·European Heart Journal

Abstract

AIMS: The EuroSCORE has been proposed to identify patients at high risk for surgical aortic valve replacement (AVR) and estimate for them the risk-benefit of percutaneous valve replacement. The aim of our study was to investigate the validity of this proposal. METHODS AND RESULTS: From 1994 to March 2006, 1545 consecutive patients with aortic stenosis underwent isolated surgical AVR at the Department of Cardiac Surgery of Heidelberg. Both additive and logistic EuroSCOREs were calculated for each patient and summed for expected 30-day mortality. Expected and observed mortalities were compared, particularly with respect to 'high-risk' status and era of operation. Overall, 30-day mortality was low (34/1545, 2.2%) and substantially overestimated by both additive (6.1%) and logistic (9.3%) EuroSCOREs. Although both EuroSCOREs stratified patients monotonically with respect to mortality risk, high-risk patients had a 3.6% mortality (29/833), whereas additive and logistic EuroSCOREs predicted 8.3 and 14.8%. Indeed, none of the 71 patients with a EuroSCORE of 11-20 (extremely high risk) died. The more recent the era of operation, the more pronounced was the discrepancy between expected and observed mortalities. CONCLUSION: Although the EuroSCORE still successfully stratifies patients undergoing surgical AVR relative to 30-day mortality, it has become increasingly uncalibrated with absolute risk, resulting in overestimation of 30-day mortality. Inaccurately predicted mortality, especially in 'high-risk' patients, renders it unsuitable for assessing risk reduction of percutaneous valve replacement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehn523

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 210

Metadata

Authors
Osswald, B. R., Gegouskov, V., Badowski-Zyla, D., Tochtermann, U., Thomas, G., Hagl, S., & Blackstone, E. H.
Venue
European Heart Journal
Published
2008-07-28
Volume
30
Issue
1
Pages
74-80
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2082138617
Cited by
210
References
0
FWCI
19.36
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Overestimation of aortic valve replacement risk by EuroSCORE: implications for percutaneous valve replacement. https://app.cochat.ai/papers/10.1093/eurheartj/ehn523
The paper
Osswald, B. R., Gegouskov, V., Badowski-Zyla, D., Tochtermann, U., Thomas, G., Hagl, S., & Blackstone, E. H. (2008). Overestimation of aortic valve replacement risk by EuroSCORE: implications for percutaneous valve replacement. European Heart Journal. https://doi.org/10.1093/eurheartj/ehn523

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.