Randomized, non-inferiority trial of three limus agent-eluting stents with different polymer coatings: the Intracoronary Stenting and Angiographic Results: Test Efficacy of 3 Limus-Eluting Stents (ISAR-TEST-4) Trial
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
AIMS: Although biodegradable polymer drug-eluting stent (DES) platforms have potential to enhance long-term clinical outcomes, data concerning their efficacy are limited to date. We previously demonstrated angiographic antirestenotic efficacy with a microporous, biodegradable polymer DES. In the current study, we hypothesized that at 12 months, its clinical safety and efficacy would be non-inferior to that of permanent polymer DES. METHODS AND RESULTS: This prospective, randomized, open-label, active-controlled trial was conducted at two tertiary referral cardiology centres in Munich, Germany. Patients presenting with stable coronary disease or acute coronary syndromes undergoing DES implantation in de novo native-vessel coronary lesions were randomly assigned to treatment with biodegradable polymer DES (rapamycin-eluting; n = 1299) or permanent polymer DES (n = 1304: rapamycin-eluting, Cypher, n = 652; or everolimus-eluting, Xience, n = 652) and underwent clinical follow-up to 1 year. The primary endpoint was a composite of cardiac death, myocardial infarction (MI) related to the target vessel, or revascularization related to the target lesion (TLR). Biodegradable polymer DES was non-inferior to permanent polymer DES concerning the primary endpoint [13.8 vs. 14.4%, respectively, P(non-inferiority) 0.005; relative risk = 0.96 (95% confidence interval, 0.78-1.17), P(superiority) = 0.66]. Biodegradable polymer DES in comparison with permanent polymer DES showed similar rates of cardiac death or MI related to the target vessel (6.3 vs. 6.2%, P = 0.94), TLR (8.8 vs. 9.4%, P = 0.58), and stent thrombosis (definite/probable: 1.0 vs. 1.5%, P = 0.29). Subgroup analysis of the biodegradable polymer DES vs. individual Cypher and Xience stent arms revealed no signal of performance difference. CONCLUSION: A biodegradable polymer rapamycin-eluting stent is non-inferior to permanent polymer-based DES in terms of clinical efficacy over 1 year. These results provide a framework for testing the potential clinical advantage of biodegradable polymer DES over the medium to long term. The trial was registered at ClinicalTrials.gov (identifier: NCT00598676).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical End Points in Coronary Stent Trials: A Case for Standardized Definitions
Cutlip, D. E., Windecker, S., Mehran, R., Boam, A., Cohen, D. J., van Es, G.-A., Gabriel Steg, P., Morel, M.-A., Mauri, L., Vranckx, P., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.685313 · Cited by 5,497
Moses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
A Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O'Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032441 · Cited by 2,749
Pathology of Drug-Eluting Stents in Humans
Joner, M., Finn, A. V., Farb, A., Mont, E. K., Kolodgie, F. D., Ladich, E., Kutys, R., Skorija, K., Gold, H. K., & Virmani, R. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.042 · Cited by 2,744
Piaggio, G., Elbourne, D. R., Pocock, S. J., Evans, S. J. W., Altman, D. G., & CONSORT Group, F. T. (2012) · JAMA · doi:10.1001/jama.2012.87802 · Cited by 2,428
Safety and Efficacy of Sirolimus- and Paclitaxel-Eluting Coronary Stents
Stone, G. W., Moses, J. W., Ellis, S. G., Schofer, J., Dawkins, K. D., Morice, M.-C., Colombo, A., Schampaert, E., Grube, E., Kirtane, A. J., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067193 · Cited by 1,631
Outcomes associated with drug-eluting and bare-metal stents: a collaborative network meta-analysis
Stettler, C., Wandel, S., Allemann, S., Kastrati, A., Morice, M. C., Schömig, A., Pfisterer, M. E., Stone, G. W., Leon, M. B., de Lezo, J. S., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61444-5 · Cited by 1,428 · cited 1×
“–9 It should be acknowledged that, in general, concerns regarding a possible excess of stent thrombosis following DES implantation have not been borne out by extensive clinical follow-up of large numbers of treated patients.(29) –31 Nonetheless, evidence does suggest that there is a temporal redistribution of post-ste…”
BackgroundSelf-citationReporting of Noninferiority and Equivalence Randomized Trials: An Extension of the CONSORT Statement
Piaggio, G., Elbourne, D. R., Altman, D. G., Pocock, S. J., Evans, S. J. W., & CONSORT Group, F. T. (2006) · JAMA · doi:10.1001/jama.295.10.1152 · Cited by 1,153 · cited 1×
“The analysis of primary and secondary endpoints was planned to be performed on an intention-to-treat basis.(27) Although there are alternative opinions preferring a per protocol analysis in trials with a non-inferiority design, in view of the absence of cross-over, this issue is of no relevance to the current study.”
MethodAnalysis of 14 Trials Comparing Sirolimus-Eluting Stents with Bare-Metal Stents
Kastrati, A., Mehilli, J., Pache, J., Kaiser, C., Valgimigli, M., Kelbæk, H., Menichelli, M., Sabaté, M., Suttorp, M. J., Baumgart, D., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067484 · Cited by 1,006
Self-citationVascular Responses to Drug Eluting Stents: Importance of Delayed Healing
Finn, A. V., Nakazawa, G., Joner, M., Kolodgie, F. D., Mont, E. K., Gold, H. K., & Virmani, R. (2007) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.107.144220 · Cited by 900
Cited by
2018 ESC/EACTS guidelines on myocardial revascularization
Neumann, F.-J., Sousa-Uva, M., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy394 · Cited by 7,167
Self-citation(2014) · European Heart Journal · doi:10.1093/eurheartj/ehu278 · Cited by 4,314
2014 ESC/EACTS Guidelines on myocardial revascularization
Kolh, P., Windecker, S., Alfonso, F., Collet, J.-P., Cremer, J., Falk, V., Filippatos, G., Hamm, C., Head, S. J., Jüni, P., et al. (2014) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezu366 · Cited by 4,199
Self-citationDeveloped with the special contribution of the European Association for Percutaneous Cardiovascular Interventions (EAPCI), Authors/Task Force Members, Wijns, W., Kolh, P., Danchin, N., Di Mario, C., Falk, V., Folliguet, T., Garg, S., Huber, K., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq277 · Cited by 3,184
2018 ESC/EACTS Guidelines on myocardial revascularization
Neumann, F.-J., Sousa-Uva, M., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · EuroIntervention · doi:10.4244/eijy19m01_01 · Cited by 1,259
Self-citationGuidelines on myocardial revascularization
The Task Force on Myocardial Revascularization of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS) (2010) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2010.08.019 · Cited by 1,004
2018 ESC/EACTS Guidelines on myocardial revascularization
Sousa-Uva, M., Neumann, F.-J., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezy289 · Cited by 989
Self-citationUrban, P., Mehran, R., Colleran, R., Angiolillo, D. J., Byrne, R. A., Capodanno, D., Cuisset, T., Cutlip, D., Eerdmans, P., Eikelboom, J., et al. (2019) · Circulation · doi:10.1161/circulationaha.119.040167 · Cited by 823
Self-citationUrban, P., Mehran, R., Colleran, R., Angiolillo, D. J., Byrne, R. A., Capodanno, D., Cuisset, T., Cutlip, D., Eerdmans, P., Eikelboom, J., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehz372 · Cited by 621
Self-citationByrne, R. A., Neumann, F.-J., Mehilli, J., Pinieck, S., Wolff, B., Tiroch, K., Schulz, S., Fusaro, M., Ott, I., Ibrahim, T., et al. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61964-3 · Cited by 459
Self-citation2014 ESC/EACTS Guidelines on myocardial revascularization
Windecker, S., Kolh, P., Alfonso, F., Collet, J.-P., Cremer, J., Falk, V., Filippatos, G., Hamm, C., Head, S. J., Jüni, P., et al. (2014) · Kardiologia Polska · doi:10.5603/kp.2014.0224 · Cited by 418
Self-citationStefanini, G. G., Byrne, R. A., Serruys, P. W., de Waha, A., Meier, B., Massberg, S., Juni, P., Schomig, A., Windecker, S., & Kastrati, A. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs086 · Cited by 384
Self-citationStefanini, G. G., Kalesan, B., Serruys, P. W., Heg, D., Buszman, P., Linke, A., Ischinger, T., Klauss, V., Eberli, F., Wijns, W., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)61672-3 · Cited by 354
2014 ESC/EACTS Guidelines on myocardial revascularization
Windecker, S., Kolh, P., Alfonso, F., Collet, J.-P., Cremer, J., Falk, V., Filippatos, G., Hamm, C., Head, S. J., Jüni, P., et al. (2015) · EuroIntervention · doi:10.4244/eijy14m09_01 · Cited by 328
Self-citationCoronary stents: historical development, current status and future directions
Iqbal, J., Gunn, J., & Serruys, P. W. (2013) · British Medical Bulletin · doi:10.1093/bmb/ldt009 · Cited by 319
Smits, P. C., Hofma, S., Togni, M., Vázquez, N., Valdés, M., Voudris, V., Slagboom, T., Goy, J.-J., Vuillomenet, A., Serra, A., et al. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61852-2 · Cited by 293
Kandzari, D. E., Mauri, L., Koolen, J. J., Massaro, J. M., Doros, G., Garcia-Garcia, H. M., Bennett, J., Roguin, A., Gharib, E. G., Cutlip, D. E., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)32249-3 · Cited by 279
Mehilli, J., Byrne, R. A., Tiroch, K., Pinieck, S., Schulz, S., Kufner, S., Massberg, S., Laugwitz, K.-L., Schömig, A., & Kastrati, A. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.02.009 · Cited by 209
Self-citationMehilli, J., Pache, J., Abdel-Wahab, M., Schulz, S., Byrne, R. A., Tiroch, K., Hausleiter, J., Seyfarth, M., Ott, I., Ibrahim, T., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)61255-5 · Cited by 187
Self-citationKufner, S., Joner, M., Schneider, S., Tölg, R., Zrenner, B., Repp, J., Starkmann, A., Xhepa, E., Ibrahim, T., Cassese, S., et al. (2017) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2017.04.024 · Cited by 176
Self-citation
Metadata
- Authors
- Byrne, R. A., Kastrati, A., Kufner, S., Massberg, S., Birkmeier, K. A., Laugwitz, K.-L., Schulz, S., Pache, J., Fusaro, M., Seyfarth, M., Schomig, A., Mehilli, J., & for the Intracoronary Stenting and Angiographic Results: Test Efficacy of 3 Limus-Eluting Stents (ISAR-TEST-4) Investigators
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-08-30
- Volume
- 30
- Issue
- 20
- Pages
- 2441-2449
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2169468271
- Cited by
- 220
- References
- 33
- FWCI
- 23.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.