AIMS: New-onset left bundle branch block (LBBB) and complete atrioventricular block (AV3B) frequently occur following transcatheter aortic valve implantation (TAVI). We sought to determine the timing and potential mechanisms of new conduction abnormalities (CAs) during TAVI, using the Medtronic CoreValve System (MCS). METHODS AND RESULTS: Sixty-five consecutive patients underwent TAVI with continuous 12-lead ECG analysis. New CAs were defined by the occurrence of LBBB, RBBB, and/or AV3B after the following pre-defined time points: (i) crossing of valve with stiff wire, (ii) positioning of balloon catheter in the aortic annulus, (iii) balloon valvuloplasty, (iv) positioning of MCS in the left ventricular outflow tract (LVOT), (v) expansion of MCS, (vi) removal of all catheters. A new CA occurred during TAVI in 48 patients (74%) and after TAVI in 5 (8%). Of the 48 patients with procedural CAs, a single new CA occurred in 43 patients (90%) and two types of CAs in 5 (10%). A new LBBB was seen in 40 patients (83%), AV3B in 9 (19%), and RBBB in 4 (8%). The new CA first occurred-in descending order of frequency-after balloon valvuloplasty in 22 patients (46%), MCS expansion in 14 (29%), MCS positioning in 6 (12%), positioning of balloon catheter in 3 (6%), wire-crossing of aortic valve in 2 (4%), and after catheter removal in 1 patient (2%). Patients who developed a new CA during balloon valvuloplasty had a significantly higher balloon/annulus ratio than those who did not (1.10±0.10 vs. 1.03±0.11, P=0.030). No such relationship was found with the valve/annulus ratio. CONCLUSION: Transcatheter aortic valve implantation with the MCS was associated with new CAs in 82% of which more than half occurred before the actual valve implantation. It remains to be elucidated by dedicated studies whether new CAs can be reduced by appropriate balloon sizing-a precept that also holds for valve size given the observed directional signal of the valve size/aortic annulus ratio.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehr110

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 191

Metadata

Authors
Nuis, R.-J., Van Mieghem, N. M., Schultz, C. J., Tzikas, A., Van der Boon, R. M., Maugenest, A.-M., Cheng, J., Piazza, N., van Domburg, R. T., Serruys, P. W., & de Jaegere, P. P.
Venue
European Heart Journal
Published
2011-05-28
Volume
32
Issue
16
Pages
2067-2074
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2149820004
Cited by
191
References
1
FWCI
18.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Timing and potential mechanisms of new conduction abnormalities during the implantation of the Medtronic CoreValve System in patients with aortic stenosis. https://app.cochat.ai/papers/10.1093/eurheartj/ehr110
The paper
Nuis, R.-J., Van Mieghem, N. M., Schultz, C. J., Tzikas, A., Van der Boon, R. M., Maugenest, A.-M., Cheng, J., Piazza, N., van Domburg, R. T., Serruys, P. W., & de Jaegere, P. P. (2011). Timing and potential mechanisms of new conduction abnormalities during the implantation of the Medtronic CoreValve System in patients with aortic stenosis. European Heart Journal. https://doi.org/10.1093/eurheartj/ehr110

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.