The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Timing and potential mechanisms of new conduction abnormalities during the implantation of the Medtronic CoreValve System in patients with aortic stenosis
Abstract
AIMS: New-onset left bundle branch block (LBBB) and complete atrioventricular block (AV3B) frequently occur following transcatheter aortic valve implantation (TAVI). We sought to determine the timing and potential mechanisms of new conduction abnormalities (CAs) during TAVI, using the Medtronic CoreValve System (MCS). METHODS AND RESULTS: Sixty-five consecutive patients underwent TAVI with continuous 12-lead ECG analysis. New CAs were defined by the occurrence of LBBB, RBBB, and/or AV3B after the following pre-defined time points: (i) crossing of valve with stiff wire, (ii) positioning of balloon catheter in the aortic annulus, (iii) balloon valvuloplasty, (iv) positioning of MCS in the left ventricular outflow tract (LVOT), (v) expansion of MCS, (vi) removal of all catheters. A new CA occurred during TAVI in 48 patients (74%) and after TAVI in 5 (8%). Of the 48 patients with procedural CAs, a single new CA occurred in 43 patients (90%) and two types of CAs in 5 (10%). A new LBBB was seen in 40 patients (83%), AV3B in 9 (19%), and RBBB in 4 (8%). The new CA first occurred-in descending order of frequency-after balloon valvuloplasty in 22 patients (46%), MCS expansion in 14 (29%), MCS positioning in 6 (12%), positioning of balloon catheter in 3 (6%), wire-crossing of aortic valve in 2 (4%), and after catheter removal in 1 patient (2%). Patients who developed a new CA during balloon valvuloplasty had a significantly higher balloon/annulus ratio than those who did not (1.10±0.10 vs. 1.03±0.11, P=0.030). No such relationship was found with the valve/annulus ratio. CONCLUSION: Transcatheter aortic valve implantation with the MCS was associated with new CAs in 82% of which more than half occurred before the actual valve implantation. It remains to be elucidated by dedicated studies whether new CAs can be reduced by appropriate balloon sizing-a precept that also holds for valve size given the observed directional signal of the valve size/aortic annulus ratio.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Cited by
Kappetein, A. P., Head, S. J., Généreux, P., Piazza, N., Mieghem, N. M. V., Blackstone, E., Brott, T., Cohen, D., Cutlip, D. E., van Es, G., et al. (2012) · doi:10.48350/15011 · Cited by 3,368
Self-citationUpdated Standardized Endpoint Definitions for Transcatheter Aortic Valve Implantation
Kappetein, A. P., Head, S. J., Généreux, P., Piazza, N., van Mieghem, N. M., Blackstone, E. H., Brott, T. G., Cohen, D. J., Cutlip, D. E., van Es, G.-A., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.09.001 · Cited by 1,668
Self-citationKappetein, A. P., Head, S. J., Genereux, P., Piazza, N., van Mieghem, N. M., Blackstone, E. H., Brott, T. G., Cohen, D. J., Cutlip, D. E., van Es, G.-A., et al. (2012) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezs533 · Cited by 1,601
Self-citationKappetein, A. P., Head, S. J., Généreux, P., Piazza, N., van Mieghem, N. M., Blackstone, E. H., Brott, T. G., Cohen, D. J., Cutlip, D. E., van Es, G.-A., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs255 · Cited by 1,043
Self-citationKappetein, A. P., Head, S. J., Généreux, P., Piazza, N., van Mieghem, N. M., Blackstone, E. H., Brott, T. G., Cohen, D. J., Cutlip, D. E., van Es, G.-A., et al. (2013) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2012.09.002 · Cited by 918
Self-citation
Metadata
- Authors
- Nuis, R.-J., Van Mieghem, N. M., Schultz, C. J., Tzikas, A., Van der Boon, R. M., Maugenest, A.-M., Cheng, J., Piazza, N., van Domburg, R. T., Serruys, P. W., & de Jaegere, P. P.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-05-28
- Volume
- 32
- Issue
- 16
- Pages
- 2067-2074
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2149820004
- Cited by
- 191
- References
- 1
- FWCI
- 18.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Timing and potential mechanisms of new conduction abnormalities during the implantation of the Medtronic CoreValve System in patients with aortic stenosis. https://app.cochat.ai/papers/10.1093/eurheartj/ehr110
- The paper
- Nuis, R.-J., Van Mieghem, N. M., Schultz, C. J., Tzikas, A., Van der Boon, R. M., Maugenest, A.-M., Cheng, J., Piazza, N., van Domburg, R. T., Serruys, P. W., & de Jaegere, P. P. (2011). Timing and potential mechanisms of new conduction abnormalities during the implantation of the Medtronic CoreValve System in patients with aortic stenosis. European Heart Journal. https://doi.org/10.1093/eurheartj/ehr110
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.