The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Computed tomography stress myocardial perfusion imaging in patients considered for revascularization: a comparison with fractional flow reserve
Open accessAbstract
AIMS: Adenosine stress computed tomography myocardial perfusion imaging (CTP) is an emerging non-invasive method for detecting myocardial ischaemia. Its value when compared with fractional flow reserve (FFR), a highly accurate index of ischaemia, is unknown. Our aim was to determine the diagnostic accuracy of CTP and its incremental value when used with computed tomography coronary angiography (CTA) for detecting ischaemia compared with FFR. METHODS AND RESULTS: Forty-two patients (126 vessel territories), who had at least one ≥50% angiographic stenosis on invasive angiography considered for non-urgent revascularization, were included and underwent FFR and CT assessment, including CTP, delayed contrast enhancement scan and CTA all acquired using 320-detector row CT, and prospective ECG gating. Fractional flow reserve was determined in 86 territories subtended by vessels with ≥50% stenosis upon visual assessment. Fractional flow reserve ≤0.8 was considered to indicate significant ischaemia. Computed tomography myocardial perfusion imaging correctly identified 31/41 (76%) ischaemic territories and 38/45 (84%) non-ischaemic territories. Per-vessel territory sensitivity, specificity, positive, and negative predictive values of CTP were 76, 84, 82, and 79%, respectively. The combination of a ≥50% stenosis on CTA and perfusion defect on CTP was 98% specific for ischaemia, while the presence of <50% stenosis on CTA and normal perfusion on CTP was 100% specific for exclusion of ischaemia. Mean radiation for CTP and combined CT was 5.3 and 11.3 mSv, respectively. CONCLUSION: Computed tomography myocardial perfusion imaging is moderately accurate in identifying perfusion defects associated with ischaemia as assessed by FFR in patients considered for revascularization. In territories, where CTA and CTP are concordant, CTA/CTP is highly accurate in the detection and exclusion of ischaemia. This is achievable with acceptable radiation exposure using 320-detector row CT and prospective ECG gating.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optimal Medical Therapy with or without PCI for Stable Coronary Disease
Boden, W. E., O'Rourke, R. A., Teo, K. K., Hartigan, P. M., Maron, D. J., Kostuk, W. J., Knudtson, M., Dada, M., Casperson, P., Harris, C. L., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa070829 · Cited by 4,699
Cited by
Takx, R. A. P., Blomberg, B. A., Aidi, H. E., Habets, J., de Jong, P. A., Nagel, E., Hoffmann, U., & Leiner, T. (2015) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.114.002666 · Cited by 427
Narula, J., Chandrashekhar, Y., Ahmadi, A., Abbara, S., Berman, D. S., Blankstein, R., Leipsic, J., Newby, D., Nicol, E. D., Nieman, K., et al. (2021) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2020.11.001 · Cited by 398
Park, J.-W., Shin, E.-S., Ann, S. H., Gödde, M., Park, L. S.-I., Brachmann, J., Vidal-Lopez, S., Wierzbinski, J., Lam, Y.-Y., & Jung, F. (2015) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-141912 · Cited by 29
Metadata
- Authors
- Ko, B. S., Cameron, J. D., Meredith, I. T., Leung, M., Antonis, P. R., Nasis, A., Crossett, M., Hope, S. A., Lehman, S. J., Troupis, J., DeFrance, T., & Seneviratne, S. K.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-08-02
- Volume
- 33
- Issue
- 1
- Pages
- 67-77
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2120212226
- Cited by
- 199
- References
- 1
- FWCI
- 17.47
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Computed tomography stress myocardial perfusion imaging in patients considered for revascularization: a comparison with fractional flow reserve. https://app.cochat.ai/papers/10.1093/eurheartj/ehr268
- The paper
- Ko, B. S., Cameron, J. D., Meredith, I. T., Leung, M., Antonis, P. R., Nasis, A., Crossett, M., Hope, S. A., Lehman, S. J., Troupis, J., DeFrance, T., & Seneviratne, S. K. (2012). Computed tomography stress myocardial perfusion imaging in patients considered for revascularization: a comparison with fractional flow reserve. European Heart Journal. https://doi.org/10.1093/eurheartj/ehr268
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.