Epicardial wave mapping in human long-lasting persistent atrial fibrillation: transient rotational circuits, complex wavefronts, and disorganized activity

Lee, Geoffrey, Kumar, Saurabh, Teh, Andrew, Madry, Andrew, Spence, Steven, Larobina, Marco, Goldblatt, John, Brown, Robin, Atkinson, Victoria, Moten, Simon, Morton, Joseph B., Sanders, Prashanthan, Kistler, Peter M., Kalman, Jonathan M. · 2014 · European Heart Journal

Abstract

OBJECTIVES: To characterize the nature of atrial fibrillation (AF) activation in human persistent AF (PerAF) using modern tools including activation, directionality analyses, complex-fractionated electrogram, and spectral information. BACKGROUND: The mechanism of PerAF in humans is uncertain. METHODS AND RESULTS: High-density epicardial mapping (128 electrodes/6.75 cm(2)) of the posterior LA wall (PLAW), LA and RA appendage (LAA, RAA), and RSPV-LA junction was performed in 18 patients with PerAF undergoing open heart surgery. Continuous 10 s recordings were analysed offline. Activation patterns were characterized into four subtypes (i) wavefronts (broad or multiple), (ii) rotational circuits (≥2 rotations of 360°), (iii) focal sources with centrifugal activation of the entire mapping area, or (iv) disorganized activity [isolated chaotic activation(s) that propagate ≤3 bipoles or activation(s) that occur as isolated beats dissociated from the activation of adjacent bipole sites]. Activation at a total of 36 regions were analysed (14 PLAW, 3 RSPV-LA, 12 LAA, and 7 RAA) creating a database of 2904 activation patterns. In the majority of maps, activation patterns were highly heterogeneous with multiple unstable activation patterns transitioning from one to another during each recording. A mean of 3.8 ± 1.6 activation subtypes was seen per map. The most common patterns seen were multiple wavefronts (56.2 ± 32%) and disorganized activity (24.2 ± 30.3%). Only 2 of 36 maps (5.5%) showed a single stable activation pattern throughout the 10-s period. These were stable planar wavefronts. Three transient rotational circuits were observed. Two of the transient circuits were located in the posterior left atrium, while the third was located on the anterior surface of the LAA. Focal activations accounted for 11.3 ± 14.2% of activations and were all short-lived (≤2 beats), with no site demonstrating sustained focal activity. CONCLUSION: Human long-lasting PerAF is characterized by heterogeneous and unstable patterns of activation including wavefronts, transient rotational circuits, and disorganized activity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/eht267

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 184

Metadata

Authors
Lee, G., Kumar, S., Teh, A., Madry, A., Spence, S., Larobina, M., Goldblatt, J., Brown, R., Atkinson, V., Moten, S., Morton, J. B., Sanders, P., Kistler, P. M., & Kalman, J. M.
Venue
European Heart Journal
Published
2013-08-08
Volume
35
Issue
2
Pages
86-97
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2112734087
Cited by
184
References
1
FWCI
14.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Epicardial wave mapping in human long-lasting persistent atrial fibrillation: transient rotational circuits, complex wavefronts, and disorganized activity. https://app.cochat.ai/papers/10.1093/eurheartj/eht267
The paper
Lee, G., Kumar, S., Teh, A., Madry, A., Spence, S., Larobina, M., Goldblatt, J., Brown, R., Atkinson, V., Moten, S., Morton, J. B., Sanders, P., Kistler, P. M., & Kalman, J. M. (2014). Epicardial wave mapping in human long-lasting persistent atrial fibrillation: transient rotational circuits, complex wavefronts, and disorganized activity. European Heart Journal. https://doi.org/10.1093/eurheartj/eht267

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.