Efficacy and safety of rivaroxaban compared with warfarin in patients with peripheral artery disease and non-valvular atrial fibrillation: insights from ROCKET AF
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
AIMS: Vascular disease is included in a risk scoring system to predict stroke in patients with non-valvular atrial fibrillation (AF). This post hoc analysis of ROCKET AF aimed to determine the absolute rates of stroke and bleeding, and the relative effectiveness and safety of rivaroxaban vs. warfarin in patients with and without peripheral artery disease (PAD). Peripheral artery disease was defined on the case-report form as the presences of intermittent claudication, amputation for arterial insufficiency, vascular reconstruction, bypass surgery, or percutaneous intervention to the extremities, or previously documented abdominal aortic aneurysm. METHODS AND RESULTS: ROCKET AF was a double-blind, double-dummy, randomized-controlled trial comparing rivaroxaban and warfarin for the prevention of stroke or systemic embolism. A total of 839 (5.9%) patients in ROCKET AF had PAD. Patients with and without PAD had similar rates of stroke or systemic embolism [HR: 1.04, 95% CI (0.72, 1.50), P = 0.84] and major or non-major clinically relevant (NMCR) bleeding [HR: 1.11, 95% CI (0.96, 1.28), P = 0.17], respectively. The efficacy of rivaroxaban when compared with warfarin for the prevention of stroke or systemic embolism was similar in patients with PAD (HR: 1.19, 95% CI: 0.63-2.22) and without PAD (HR: 0.86, 95% CI: 0.73-1.02; interaction P = 0.34). There was a significant interaction for major or NMCR bleeding in patients with PAD treated with rivaroxaban compared with warfarin (HR: 1.40, 95% CI: 1.06-1.86) compared with those without PAD (HR: 1.03, 95% CI: 0.95-1.11; interaction P = 0.037). CONCLUSION: Patients with PAD in ROCKET AF did not have a statistically significant higher risk of stroke or systemic embolism than patients without PAD, and there were similar efficacy outcomes in patients treated with rivaroxaban and warfarin. In PAD patients, there was a higher risk of major bleeding or NMCR bleeding with rivaroxaban when compared with warfarin (interaction P = 0.037). Further investigation is warranted to validate this subgroup analysis and determine the optimal treatment in this high-risk cohort of AF patients with PAD.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rivaroxaban versus warfarin in nonvalvular atrial fibrillation
Patel, M. R., Mahaffey, K. W., Garg, J., Pan, G., Singer, D. E., Hacke, W., Breithardt, G., Halperin, J. L., Hankey, G. J., Piccini, J. P., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1009638 · Cited by 9,430
Self-citationCollaboration, A. T. (2002) · BMJ · doi:10.1136/bmj.324.7329.71 · Cited by 6,943
Lip, G. Y. H., Nieuwlaat, R., Pisters, R., Lane, D. A., & Crijns, H. J. G. M. (2010) · Chest · doi:10.1378/chest.09-1584 · Cited by 6,879
Gage, B. F., van Walraven, C., Pearce, L., Hart, R. G., Koudstaal, P. J., Boode, B. S. P., & Petersen, P. (2004) · Circulation · doi:10.1161/01.cir.0000145172.55640.93 · Cited by 749 · cited 1×
“8 Owing to these factors, an evidence gap exists surrounding the prognostic significance of PAD in patients with AF and the efficacy and safety of concomitant anti-platelet and anticoagulant medications in PAD patients with AF, and the optimal combination of antithrombotic medications is unknown.(3,4,9) In the Rivarox…”
Background
Cited by
Aboyans, V., Ricco, J.-B., Bartelink, M.-L. E. L., Björck, M., Brodmann, M., Cohnert, T., Collet, J.-P., Czerny, M., De Carlo, M., Debus, S., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehx095 · Cited by 3,293
Van Gelder, I. C., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., De Potter, T. J. R., Dwight, J., Guasti, L., Hanke, T., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae176 · Cited by 3,024
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 2,765
Self-citationAboyans, V., Ricco, J.-B., Bartelink, M.-L. E. L., Björck, M., Brodmann, M., Cohnert, T., Collet, J.-P., Czerny, M., De Carlo, M., Debus, S., et al. (2018) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2017.07.018 · Cited by 963
Antithrombotic Therapy for Atrial Fibrillation
Lip, G. Y. H., Banerjee, A., Boriani, G., Chiang, C. E., Fargo, R., Freedman, B., Lane, D. A., Ruff, C. T., Turakhia, M., Werring, D., et al. (2018) · Chest · doi:10.1016/j.chest.2018.07.040 · Cited by 939
Metadata
- Authors
- Jones, W. S., Hellkamp, A. S., Halperin, J., Piccini, J. P., Breithardt, G., Singer, D. E., Fox, K. A. A., Hankey, G. J., Mahaffey, K. W., Califf, R. M., & Patel, M. R.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-12-02
- Volume
- 35
- Issue
- 4
- Pages
- 242-249
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2113645730
- Cited by
- 91
- References
- 4
- FWCI
- 4.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Efficacy and safety of rivaroxaban compared with warfarin in patients with peripheral artery disease and non-valvular atrial fibrillation: insights from ROCKET AF. https://app.cochat.ai/papers/10.1093/eurheartj/eht492
- The paper
- Jones, W. S., Hellkamp, A. S., Halperin, J., Piccini, J. P., Breithardt, G., Singer, D. E., Fox, K. A. A., Hankey, G. J., Mahaffey, K. W., Califf, R. M., & Patel, M. R. (2014). Efficacy and safety of rivaroxaban compared with warfarin in patients with peripheral artery disease and non-valvular atrial fibrillation: insights from ROCKET AF. European Heart Journal. https://doi.org/10.1093/eurheartj/eht492
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.