Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 213

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Direct comparison of high-sensitivity-cardiac troponin I vs. T for the early diagnosis of acute myocardial infarction

Rubini Gimenez, M., Twerenbold, R., Reichlin, T., Wildi, K., Haaf, P., Schaefer, M., Zellweger, C., Moehring, B., Stallone, F., Sou, S. M., Mueller, M., Denhaerynck, K., Mosimann, T., Reiter, M., Meller, B., Freese, M., Stelzig, C., Klimmeck, I., Voegele, J., Hartmann, B., Rentsch, K., Osswald, S., Mueller, C.·2014·European Heart Journal

Abstract

AIM: It is unknown whether cardiac troponin (cTn) I or cTnT is the preferred biomarker in the early diagnosis of acute myocardial infarction without ST segment elevation (NSTEMI). METHODS AND RESULTS: In a prospective multicentre study, we measured cTnI and cTnT using clinically available high-sensitivity assays (hs-cTnI Abbott and hs-cTnT Roche) and compared their diagnostic and prognostic accuracies in consecutive patients presenting to the emergency department with acute chest pain. The final diagnosis was adjudicated by two independent cardiologists using all information pertaining to the individual patient. The mean follow-up was 24 months. Among 2226 consecutive patients, 18% had an adjudicated final diagnosis of NSTEMI. Diagnostic accuracy at presentation as quantified by the area under the receiver-operating-characteristics curve (AUC) for NSTEMI was very high and similar for hs-cTnI [AUC: 0.93, 95% confidence interval (CI) 0.92-0.94] and hs-cTnT (0.94, 95% CI: 0.92-0.94) P = 0.62. In early presenters (<3 h since chest pain onset) hs-cTnI showed a higher diagnostic accuracy (AUC: 0.92, 95% CI: 0.89-0.94) when compared with hs-cTnT AUC (0.89, 95% CI: 0.86-0.91) (P = 0.019), while hs-cTnT was superior in late presenters [AUC hs-cTnT 0.96 (95% CI: 0.94-0.96) vs. hs-cTnI 0.94 (95% CI: 0.93-0.95); P = 0.007]. The prognostic accuracy for all-cause mortality, quantified by AUC, was significantly higher for hs-cTnT (AUC: 0.80; 95% CI: 0.78-0.82) when compared with hs-cTnI (AUC: 0.75; 95% CI: 0.73-0.77; P < 0.001). CONCLUSION: Both hs-cTnI and hs-cTnT provided high diagnostic and prognostic accuracy. The direct comparison revealed small but potentially important differences that might help to further improve the clinical use of hs-cTn.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehu188

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 213

Metadata

Authors
Rubini Gimenez, M., Twerenbold, R., Reichlin, T., Wildi, K., Haaf, P., Schaefer, M., Zellweger, C., Moehring, B., Stallone, F., Sou, S. M., Mueller, M., Denhaerynck, K., Mosimann, T., Reiter, M., Meller, B., Freese, M., Stelzig, C., Klimmeck, I., Voegele, J., Hartmann, B., Rentsch, K., Osswald, S., & Mueller, C.
Venue
European Heart Journal
Published
2014-05-19
Volume
35
Issue
34
Pages
2303-2311
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2112462515
Cited by
213
References
4
FWCI
13.06
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Direct comparison of high-sensitivity-cardiac troponin I vs. T for the early diagnosis of acute myocardial infarction. https://app.cochat.ai/papers/10.1093/eurheartj/ehu188
The paper
Rubini Gimenez, M., Twerenbold, R., Reichlin, T., Wildi, K., Haaf, P., Schaefer, M., Zellweger, C., Moehring, B., Stallone, F., Sou, S. M., Mueller, M., Denhaerynck, K., Mosimann, T., Reiter, M., Meller, B., Freese, M., Stelzig, C., Klimmeck, I., Voegele, J., . . . Mueller, C. (2014). Direct comparison of high-sensitivity-cardiac troponin I vs. T for the early diagnosis of acute myocardial infarction. European Heart Journal. https://doi.org/10.1093/eurheartj/ehu188

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.