Current worldwide nuclear cardiology practices and radiation exposure: results from the 65 country IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS)
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
AIMS: To characterize patient radiation doses from nuclear myocardial perfusion imaging (MPI) and the use of radiation-optimizing 'best practices' worldwide, and to evaluate the relationship between laboratory use of best practices and patient radiation dose. METHODS AND RESULTS: We conducted an observational cross-sectional study of protocols used for all 7911 MPI studies performed in 308 nuclear cardiology laboratories in 65 countries for a single week in March-April 2013. Eight 'best practices' relating to radiation exposure were identified a priori by an expert committee, and a radiation-related quality index (QI) devised indicating the number of best practices used by a laboratory. Patient radiation effective dose (ED) ranged between 0.8 and 35.6 mSv (median 10.0 mSv). Average laboratory ED ranged from 2.2 to 24.4 mSv (median 10.4 mSv); only 91 (30%) laboratories achieved the median ED ≤ 9 mSv recommended by guidelines. Laboratory QIs ranged from 2 to 8 (median 5). Both ED and QI differed significantly between laboratories, countries, and world regions. The lowest median ED (8.0 mSv), in Europe, coincided with high best-practice adherence (mean laboratory QI 6.2). The highest doses (median 12.1 mSv) and low QI (4.9) occurred in Latin America. In hierarchical regression modelling, patients undergoing MPI at laboratories following more 'best practices' had lower EDs. CONCLUSION: Marked worldwide variation exists in radiation safety practices pertaining to MPI, with targeted EDs currently achieved in a minority of laboratories. The significant relationship between best-practice implementation and lower doses indicates numerous opportunities to reduce radiation exposure from MPI globally.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
International Atomic Energy Agency
(2022) · Permanent Missions to the United Nations · doi:10.18356/9789210018289c237 · Cited by 3,890
Hachamovitch, R., Hayes, S. W., Friedman, J. D., Cohen, I., & Berman, D. S. (2003) · Circulation · doi:10.1161/01.cir.0000072790.23090.41 · Cited by 1,563
Exposure to Low-Dose Ionizing Radiation from Medical Imaging Procedures
Fazel, R., Krumholz, H. M., Wang, Y., Ross, J. S., Chen, J., Ting, H. H., Shah, N. D., Nasir, K., Einstein, A. J., & Nallamothu, B. K. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0901249 · Cited by 1,338 · cited 1×
“While considerable worldwide variation exists in the frequency of MPI use,(11) in some settings, such as the USA, it is the medical test with the highest per capita radiation dose.(9,12,13) Estimation of risk from ionizing radiation is difficult, since no prospective trials focusing on adverse events of radiation with…”
BackgroundSelf-citationEstimated Radiation Dose Associated With Cardiac CT Angiography
Hausleiter, J. (2009) · JAMA · doi:10.1001/jama.2009.54 · Cited by 1,000
Radiation Dose to Patients From Cardiac Diagnostic Imaging
Einstein, A. J., Moser, K. W., Thompson, R. C., Cerqueira, M. D., & Henzlova, M. J. (2007) · Circulation · doi:10.1161/circulationaha.107.688101 · Cited by 806 · cited 2×
“Dual isotope MPI is associated with the highest radiation dose of any protocol.(29)”
BackgroundSelf-citationMoran, A. E., Forouzanfar, M. H., Roth, G. A., Mensah, G. A., Ezzati, M., Murray, C. J. L., & Naghavi, M. (2014) · Circulation · doi:10.1161/circulationaha.113.004042 · Cited by 575
EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology
Hesse, B., Tägil, K., Cuocolo, A., Anagnostopoulos, C., Bardiés, M., Bax, J., Bengel, F., Busemann Sokole, E., Davies, G., Dondi, M., et al. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-1779-y · Cited by 527 · cited 2×
“Reflecting guidelines, we considered a second injection of less than three times the activity of the first injection to constitute dosing that can lead to shine through.(14,15,21,30)”
BackgroundMethodSelf-citationThe Prognostic Value of Normal Exercise Myocardial Perfusion Imaging and Exercise Echocardiography
Metz, L. D., Beattie, M., Hom, R., Redberg, R. F., Grady, D., & Fleischmann, K. E. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.08.048 · Cited by 471
Jaarsma, C., Leiner, T., Bekkers, S. C., Crijns, H. J., Wildberger, J. E., Nagel, E., Nelemans, P. J., & Schalla, S. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.12.040 · Cited by 456
ICRP Publication 120: Radiological Protection in Cardiology
Cousins, C., Miller, D. L., Bernardi, G., Rehani, M. M., Schofield, P., Vañó, E., Einstein, A. J., Geiger, B., Heintz, P., Padovani, R., et al. (2013) · Annals of the ICRP · doi:10.1016/j.icrp.2012.09.001 · Cited by 428
Self-citation
Cited by
ASNC imaging guidelines for SPECT nuclear cardiology procedures: Stress, protocols, and tracers
Henzlova, M. J., Duvall, W. L., Einstein, A. J., Travin, M. I., & Verberne, H. J. (2016) · Journal of Nuclear Cardiology · doi:10.1007/s12350-015-0387-x · Cited by 700
Self-citationInternational Impact of COVID-19 on the Diagnosis of Heart Disease
Einstein, A. J., Shaw, L. J., Hirschfeld, C., Williams, M. C., Villines, T. C., Better, N., Vitola, J. V., Cerci, R., Dorbala, S., Raggi, P., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.10.054 · Cited by 190
“New weekend hours 3 (7) 8 (13) 14 (14) 15 (8) 6 (10) 15 (9) 4 (5) 21 (11) 86 (10)”
Self-citation
Metadata
- Authors
- Einstein, A. J., Pascual, T. N. B., Mercuri, M., Karthikeyan, G., Vitola, J. V., Mahmarian, J. J., Better, N., Bouyoucef, S. E., Hee-Seung Bom, H., Lele, V., Magboo, V. P. C., Alexánderson, E., Allam, A. H., Al-Mallah, M. H., Flotats, A., Jerome, S., Kaufmann, P. A., Luxenburg, O., Shaw, L. J., Underwood, S. R., Rehani, M. M., Kashyap, R., Paez, D., & Dondi, M.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-04-21
- Volume
- 36
- Issue
- 26
- Pages
- 1689-1696
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2116416278
- Cited by
- 181
- References
- 24
- FWCI
- 18.97
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Current worldwide nuclear cardiology practices and radiation exposure: results from the 65 country IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS). https://app.cochat.ai/papers/10.1093/eurheartj/ehv117
- The paper
- Einstein, A. J., Pascual, T. N. B., Mercuri, M., Karthikeyan, G., Vitola, J. V., Mahmarian, J. J., Better, N., Bouyoucef, S. E., Hee-Seung Bom, H., Lele, V., Magboo, V. P. C., Alexánderson, E., Allam, A. H., Al-Mallah, M. H., Flotats, A., Jerome, S., Kaufmann, P. A., Luxenburg, O., Shaw, L. J., . . . Dondi, M. (2015). Current worldwide nuclear cardiology practices and radiation exposure: results from the 65 country IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS). European Heart Journal. https://doi.org/10.1093/eurheartj/ehv117
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.