Comparison of vascular closure devices for access site closure after transfemoral aortic valve implantation
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The majority of transcatheter aortic valve implantation (TAVI) procedures are currently performed by percutaneous transfemoral approach. The potential contribution of the type of vascular closure device to the incidence of vascular complications is not clear. AIM: To compare the efficacy of a Prostar XL- vs. Perclose ProGlide-based vascular closure strategy. METHODS: The ClOsure device iN TRansfemoral aOrtic vaLve implantation (CONTROL) multi-center study included 3138 consecutive percutaneous transfemoral TAVI patients, categorized according to vascular closure strategy: Prostar XL- (Prostar group) vs. Perclose ProGlide-based vascular closure strategy (ProGlide group). Propensity-score matching was used to assemble a cohort of patients with similar baseline characteristics. RESULTS: Propensity matching identified 944 well-matched patients (472 patient pairs). Composite primary end point of major vascular complications or in-hospital mortality occurred more frequently in Prostar group when compared with ProGlide group (9.5 vs. 5.1%, P = 0.016), and was driven by higher rates of major vascular complication (7.4 vs. 1.9%, P < 0.001) in the Prostar group. However, in-hospital mortality was similar between groups (4.9 vs. 3.5%, P = 0.2). Femoral artery stenosis occurred less frequently in the Prostar group (3.4 vs. 0.5%, P = 0.004), but overall, Prostar use was associated with higher rates of major bleeding (16.7 vs. 3.2%, P < 0.001), acute kidney injury (17.6 vs. 4.4%, P < 0.001) and with longer hospital stay (median 6 vs. 5 days, P = 0.007). CONCLUSIONS: Prostar XL-based vascular closure in transfemoral TAVI procedures is associated with higher major vascular complication rates when compared with ProGlide; however, in-hospital mortality is similar with both devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kappetein, A. P., Head, S. J., Généreux, P., Piazza, N., Mieghem, N. M. V., Blackstone, E., Brott, T., Cohen, D., Cutlip, D. E., van Es, G., et al. (2012) · doi:10.48350/15011 · Cited by 3,368
Self-citationUpdated Standardized Endpoint Definitions for Transcatheter Aortic Valve Implantation
Kappetein, A. P., Head, S. J., Généreux, P., Piazza, N., van Mieghem, N. M., Blackstone, E. H., Brott, T. G., Cohen, D. J., Cutlip, D. E., van Es, G.-A., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.09.001 · Cited by 1,668
Self-citationRegistry of Transcatheter Aortic-Valve Implantation in High-Risk Patients
Gilard, M., Eltchaninoff, H., Iung, B., Donzeau-Gouge, P., Chevreul, K., Fajadet, J., Leprince, P., Leguerrier, A., Lievre, M., Prat, A., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1114705 · Cited by 1,228
Self-citationLittle, R. J., & Rubin, D. B. (2000) · Annual Review of Public Health · doi:10.1146/annurev.publhealth.21.1.121 · Cited by 721 · cited 1×
“The propensity score is a conditional probability of having a particular exposure (Prostar or ProGlide) given a set of baseline measured covariates.(17) The propensity score has been developed using a logistic regression model according to a non-parsimonious approach.”
MethodGénéreux, P., Head, S. J., Van Mieghem, N. M., Kodali, S., Kirtane, A. J., Xu, K., Smith, C., Serruys, P. W., Kappetein, A. P., & Leon, M. B. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.02.022 · Cited by 593
Transfemoral Aortic Valve Implantation
Hayashida, K., Lefèvre, T., Chevalier, B., Hovasse, T., Romano, M., Garot, P., Mylotte, D., Uribe, J., Farge, A., Donzeau-Gouge, P., et al. (2011) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2011.03.019 · Cited by 564
Vascular Complications After Transcatheter Aortic Valve Replacement
Généreux, P., Webb, J. G., Svensson, L. G., Kodali, S. K., Satler, L. F., Fearon, W. F., Davidson, C. J., Eisenhauer, A. C., Makkar, R. R., Bergman, G. W., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.003 · Cited by 518
Self-citationRegistry of Transcatheter Aortic-Valve Implantation in High-Risk Patients
Gilard, M., Eltchaninoff, H., Iung, Donzeau-Gouge, P., Chevreul, K., Fajadet, J., Leprince, P., Leguerrier, A., Lievre, M., Prat, A., et al. (2013) · Survey of Anesthesiology · doi:10.1097/01.sa.0000426523.25196.4e · Cited by 454
Self-citationPercutaneous Aortic Valve Replacement
Toggweiler, S., Gurvitch, R., Leipsic, J., Wood, D. A., Willson, A. B., Binder, R. K., Cheung, A., Ye, J., & Webb, J. G. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.069 · Cited by 322
Self-citationBlackstone, E. H., Suri, R. M., Rajeswaran, J., Babaliaros, V., Douglas, P. S., Fearon, W. F., Miller, D. C., Hahn, R. T., Kapadia, S., Kirtane, A. J., et al. (2015) · Circulation · doi:10.1161/circulationaha.114.012525 · Cited by 290
Nelson, P. R., Kracjer, Z., Kansal, N., Rao, V., Bianchi, C., Hashemi, H., Jones, P., & Bacharach, J. M. (2014) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2013.10.101 · Cited by 281
Généreux, P., Cohen, D. J., Williams, M. R., Mack, M., Kodali, S. K., Svensson, L. G., Kirtane, A. J., Xu, K., McAndrew, T. C., Makkar, R., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.10.058 · Cited by 192
Self-citationBarbanti, M., Binder, R. K., Freeman, M., Wood, D. A., Leipsic, J. A., Cheung, A. W., Ye, J., Tan, J., Toggweiler, S., Yang, T., et al. (2013) · EuroIntervention · doi:10.4244/eijv9i8a156 · Cited by 125
Self-citationTrue Percutaneous Approach for Transfemoral Aortic Valve Implantation Using the Prostar XL Device
Hayashida, K., Lefèvre, T., Chevalier, B., Hovasse, T., Romano, M., Garot, P., Mylotte, D., Uribe, J., Farge, A., Donzeau‐Gouge, P., et al. (2012) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2011.09.020 · Cited by 110
Griese, D. P., Reents, W., Diegeler, A., Kerber, S., & Babin–Ebell, J. (2013) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.25053 · Cited by 88
Blackman, D. J., Baxter, P. D., Gale, C. P., Moat, N. E., MacCarthy, P. A., Hildick‐Smith, D., Trivedi, U., Cunningham, D., de Belder, M., & Ludman, P. (2013) · Journal of Interventional Cardiology · doi:10.1111/joic.12084 · Cited by 81
Transcatheter aortic valve implantation and bleeding: incidence, predictors and prognosis
Pilgrim, T., Stortecky, S., Luterbacher, F., Windecker, S., & Wenaweser, P. (2012) · Journal of Thrombosis and Thrombolysis · doi:10.1007/s11239-012-0842-3 · Cited by 78
Kadakia, M. B., Herrmann, H. C., Desai, N. D., Fox, Z. E., Ogbara, J., Anwaruddin, S., Jagasia, D. H., Bavaria, J. E., Szeto, W. Y., Vallabhajosyula, P., et al. (2014) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.113.001030 · Cited by 71
Krishnaswamy, A., Parashar, A., Agarwal, S., Modi, D. K., Poddar, K. L., Svensson, L. G., Roselli, E. E., Schoenhagen, P., Tuzcu, E. M., & Kapadia, S. R. (2014) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.25488 · Cited by 54
Cockburn, J., de Belder, A., Brooks, M., Hutchinson, N., Hill, A., Trivedi, U., & Hildick‐Smith, D. (2011) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.23105 · Cited by 40
Amabile, N., Azmoun, A., Ghostine, S., Ramadan, R., Haddouche, Y., Raoux, F., To, N.-T., Troussier, X., Nottin, R., & Caussin, C. (2012) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.09.025 · Cited by 32
Agarwal, S., Tuzcu, E. M., Stewart, W. J., Bajaj, N. S., Svensson, L. G., & Kapadia, S. R. (2013) · Indian Heart Journal · doi:10.1016/j.ihj.2013.06.007 · Cited by 22
Cited by
Généreux, P., Piazza, N., Alu, M. C., Nazif, T., Hahn, R. T., Pibarot, P., Bax, J. J., Leipsic, J. A., Blanke, P., Blackstone, E. H., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.02.038 · Cited by 1,313
Self-citationVARC-3 WRITING COMMITTEE, Généreux, P., Piazza, N., Alu, M. C., Nazif, T., Hahn, R. T., Pibarot, P., Bax, J. J., Leipsic, J. A., Blanke, P., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa799 · Cited by 915
Self-citation
Metadata
- Authors
- Barbash, I. M., Barbanti, M., Webb, J., Molina-Martin De Nicolas, J., Abramowitz, Y., Latib, A., Nguyen, C., Deuschl, F., Segev, A., Sideris, K., Buccheri, S., Simonato, M., Rosa, F. D., Tamburino, C., Jilaihawi, H., Miyazaki, T., Himbert, D., Schofer, N., Guetta, V., Bleiziffer, S., Tchetche, D., Immè, S., Makkar, R. R., Vahanian, A., Treede, H., Lange, R., Colombo, A., & Dvir, D.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-08-26
- Volume
- 36
- Issue
- 47
- Pages
- 3370-3379
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2136594104
- Cited by
- 172
- References
- 22
- FWCI
- 10.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.