Imaging- and physiology-guided percutaneous coronary intervention without contrast administration in advanced renal failure: a feasibility, safety, and outcome study
Open accessThe DOI matches its Crossref record.
Abstract
AIMS: The feasibility, safety, and clinical utility of percutaneous coronary intervention (PCI) without radio-contrast medium in patients with advanced chronic kidney disease (CKD) are unknown. In this series, we investigated a specific strategy for 'zero contrast' PCI with the aims of preserving renal function and preventing the need for renal replacement therapy (RRT) in patients with advanced CKD. METHODS AND RESULTS: ] who had clinical indication for PCI based on a prior minimal contrast coronary angiogram were included. Zero contrast PCI was performed at least 1 week after diagnostic angiography using real-time intravascular ultrasound (IVUS) guidance, with pre- and post-PCI measurements of fractional flow reserve and coronary flow reserve to confirm physiological improvement. This approach resulted in successful PCI, no major adverse cardiovascular events and preservation of renal function without the need for RRT within a follow-up time of 79 days (IQR 33-207) in all patients. CONCLUSION: In patients with advanced CKD who require revascularization, PCI may safely be performed without contrast using IVUS and physiological guidance with high procedural success and without complications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Räber, L., Mintz, G. S., Koskinas, K. C., Johnson, T. W., Holm, N. R., Onuma, Y., Radu, M. D., Joner, M., Yu, B., Jia, H., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy285 · Cited by 770
Self-citationManagement of coronary disease in patients with advanced kidney disease
Bangalore, S., Maron, D. J., O’Brien, S. M., Fleg, J. L., Kretov, E. I., Briguori, C., Kaul, U., Reynolds, H. R., Mazurek, T., Sidhu, M. S., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa1915925 · Cited by 499
Self-citationIntravascular Imaging During Percutaneous Coronary Intervention
Truesdell, A. G., Alasnag, M. A., Kaul, P., Rab, S. T., Riley, R. F., Young, M. N., Batchelor, W. B., Maehara, A., Welt, F. G., & Kirtane, A. J. (2023) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2022.11.045 · Cited by 222
Self-citation
Metadata
- Authors
- Ali, Z. A., Karimi Galougahi, K., Nazif, T., Maehara, A., Hardy, M. A., Cohen, D. J., Ratner, L. E., Collins, M. B., Moses, J. W., Kirtane, A. J., Stone, G. W., Karmpaliotis, D., & Leon, M. B.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2016-03-07
- Volume
- 37
- Issue
- 40
- Pages
- 3090-3095
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2293898293
- Cited by
- 195
- References
- 0
- FWCI
- 20.58
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Imaging- and physiology-guided percutaneous coronary intervention without contrast administration in advanced renal failure: a feasibility, safety, and outcome study. https://app.cochat.ai/papers/10.1093/eurheartj/ehw078
- The paper
- Ali, Z. A., Karimi Galougahi, K., Nazif, T., Maehara, A., Hardy, M. A., Cohen, D. J., Ratner, L. E., Collins, M. B., Moses, J. W., Kirtane, A. J., Stone, G. W., Karmpaliotis, D., & Leon, M. B. (2016). Imaging- and physiology-guided percutaneous coronary intervention without contrast administration in advanced renal failure: a feasibility, safety, and outcome study. European Heart Journal. https://doi.org/10.1093/eurheartj/ehw078
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.