CoChat

Achieved diastolic blood pressure and pulse pressure at target systolic blood pressure (120–140 mmHg) and cardiovascular outcomes in high-risk patients: results from ONTARGET and TRANSCEND trials

Böhm, Michael, Schumacher, Helmut, Teo, Koon K, Lonn, Eva, Mahfoud, Felix, Mann, Johannes F E, Mancia, Giuseppe, Redon, Josep, Schmieder, Roland, Weber, Michael, Sliwa, Karen, Williams, Bryan, Yusuf, Salim · 2018 · European Heart Journal
Cited by 128

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Aims: Current guidelines of hypertensive management recommend upper limits for systolic (SBP) and diastolic blood pressure (DBP). J-curve associations of BP with risk exist for some outcomes suggesting that lower limits of DBP goals may also apply. We examined the association between mean attained DBP and cardiovascular (CV) outcomes in patients who achieved an on-treatment SBP in the range of 120 to <140 mmHg in the Ongoing Telmisartan Alone and in Combination with Ramipril Global Endpoint Trial (ONTARGET) and Telmisartan Randomized AssessmeNt Study in ACE iNtolerant participants with cardiovascular Disease (TRANSCEND) trials on patients with high CV risk. This SBP range was associated with the lowest CV risk. Methods: We analysed the outcome data from patients age 55 years or older with CV disease from the ONTARGET and TRANSCEND trials that randomized high-risk patients to ramipril, telmisartan, and the combination. In patients with controlled SBP (on-treatment 120 to <140 mmHg), the composite outcome of CV death, myocardial infarction, stroke and hospital admission for heart failure, the components thereof, and all-cause mortality were analysed according to mean on-treatment DBP as categorical (<70, 70 to <80, 80 to <90, and ≥90 mmHg) and continuous variable as well as the change of DBP according to baseline DBP. Pulse pressure (PP) was related to outcomes as a continuous variable. Results: In 16 099 of 31 546 patients, mean achieved SBP was 120 to <140 mmHg. The nominally lowest risk for all outcomes was observed at an achieved DBP of 70 to <80 mmHg. A higher achieved DBP was associated with a higher risk for the outcomes of stroke and of hospitalization for heart failure (≥80 mmHg) and myocardial infarction (≥90 mmHg). A lower achieved DBP (<70 mmHg) was associated with a higher risk for the primary outcome [hazard ratio (HR) 1.29, 95% confidence interval (95% CI) 1.15-1.45; P < 0.0001], myocardial infarction HR 1.54 (95% CI 1.26-1.88, P < 0.0001) and hospitalization for heart failure HR 1.81 (95% CI 1.47-2.24, P < 0.0001) and all-cause death (HR 1.19, 95% CI 1.04-1.35; P < 0.0001) while there was no signal for stroke and CV death compared to DBP 70 to <80 mmHg. A decrease of DBP was associated with lower risk when baseline DBP was >80 mmHg. The associations to outcomes were similar when patients were divided to SBP 120 to <130 mmHg or 130 to <140 mmHg for DBP or PP. Conclusion: Compared to a DBP of 70 to <80 mmHg, lower and higher DBP was associated with a higher risk in patients achieving a SBP of 120 to <140 mmHg. Associations of DBP and PP to risk were similar notably at controlled SBP. These data suggest at optimal achieved SBP, risk is still defined by low or high DBP. These findings support guidelines which take DBP at optimal SBP control into consideration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehy287

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 128

Metadata

Authors
Böhm, M., Schumacher, H., Teo, K. K., Lonn, E., Mahfoud, F., Mann, J. F. E., Mancia, G., Redon, J., Schmieder, R., Weber, M., Sliwa, K., Williams, B., & Yusuf, S.
Venue
European Heart Journal
Published
2018-06-04
Volume
39
Issue
33
Pages
3105-3114
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2807154306
Cited by
128
References
8
FWCI
10.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Achieved diastolic blood pressure and pulse pressure at target systolic blood pressure (120–140 mmHg) and cardiovascular outcomes in high-risk patients: results from ONTARGET and TRANSCEND trials. https://app.cochat.ai/papers/10.1093/eurheartj/ehy287
The paper
Böhm, M., Schumacher, H., Teo, K. K., Lonn, E., Mahfoud, F., Mann, J. F. E., Mancia, G., Redon, J., Schmieder, R., Weber, M., Sliwa, K., Williams, B., & Yusuf, S. (2018). Achieved diastolic blood pressure and pulse pressure at target systolic blood pressure (120–140 mmHg) and cardiovascular outcomes in high-risk patients: results from ONTARGET and TRANSCEND trials. European Heart Journal. https://doi.org/10.1093/eurheartj/ehy287

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.