The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The V6-V1 interpeak interval: a novel criterion for the diagnosis of left bundle branch capture
Open accessAbstract
Aims: We hypothesized that during left bundle branch (LBB) area pacing, the various possible combinations of direct capture/non-capture of the septal myocardium and the LBB result in distinct patterns of right and left ventricular activation. This could translate into different combinations of R-wave peak time (RWPT) in V1 and V6. Consequently, the V6-V1 interpeak interval could differentiate the three types of LBB area capture: non-selective (ns-)LBB, selective (s-)LBB, and left ventricular septal (LVS). Methods and results: Patients with unquestionable evidence of LBB capture were included. The V6-V1 interpeak interval, V6RWPT, and V1RWPT were compared between different types of LBB area capture. A total of 468 patients from two centres were screened, with 124 patients (239 electrocardiograms) included in the analysis. Loss of LVS capture resulted in an increase in V1RWPT by ≥15 ms but did not impact V6RWPT. Loss of LBB capture resulted in an increase in V6RWPT by ≥15 ms but only minimally influenced V1RWPT. Consequently, the V6-V1 interval was longest during s-LBB capture (62.3 ± 21.4 ms), intermediate during ns-LBB capture (41.3 ± 14.0 ms), and shortest during LVS capture (26.5 ± 8.6 ms). The optimal value of the V6-V1 interval value for the differentiation between ns-LBB and LVS capture was 33 ms (area under the receiver operating characteristic curve of 84.7%). A specificity of 100% for the diagnosis of LBB capture was obtained with a cut-off value of >44 ms. Conclusion: The V6-V1 interpeak interval is a promising novel criterion for the diagnosis of LBB area capture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vijayaraman, P., Subzposh, F. A., Naperkowski, A., Panikkath, R., John, K., Mascarenhas, V., Bauch, T. D., & Huang, W. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2019.05.011 · Cited by 396
Self-citation
Cited by
Chung, M. K., Patton, K. K., Lau, C.-P., Dal Forno, A. R. J., Al-Khatib, S. M., Arora, V., Birgersdotter-Green, U. M., Cha, Y.-M., Chung, E. H., Cronin, E. M., et al. (2023) · Heart Rhythm · doi:10.1016/j.hrthm.2023.03.1538 · Cited by 548
Self-citationLeft bundle branch area pacing outcomes: the multicentre European MELOS study
Jastrzębski, M., Kiełbasa, G., Cano, O., Curila, K., Heckman, L., De Pooter, J., Chovanec, M., Rademakers, L., Huybrechts, W., Grieco, D., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac445 · Cited by 517
Self-citationBurri, H., Jastrzebski, M., Cano, Ó., Čurila, K., de Pooter, J., Huang, W., Israel, C., Joza, J., Romero, J., Vernooy, K., et al. (2023) · Europace · doi:10.1093/europace/euad043 · Cited by 432
Self-citation
Metadata
- Authors
- Jastrzębski, M., Burri, H., Kiełbasa, G., Curila, K., Moskal, P., Bednarek, A., Rajzer, M., & Vijayaraman, P.
- Venue
- EP Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2021-07-12
- Volume
- 24
- Issue
- 1
- Pages
- 40-47
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W3181786986
- Cited by
- 190
- References
- 1
- FWCI
- 18.33
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.