Analysis of surface electrocardiograms in atrial fibrillation: techniques, research, and clinical applications
The DOI matches its Crossref record; 76 of the 76 references it cites were found in a registry or an index.
Abstract
Atrial fibrillation (AF) is the most common arrhythmia encountered in clinical practice. Neither the natural history of AF nor its response to therapy is sufficiently predictable by clinical and echocardiographic parameters. The purpose of this article is to describe technical aspects of novel electrocardiogram (ECG) analysis techniques and to present research and clinical applications of these methods for characterization of both the fibrillatory process and the ventricular response during AF. Atrial fibrillatory frequency (or rate) can reliably be assessed from the surface ECG using digital signal processing (extraction of atrial signals and spectral analysis). This measurement shows large inter-individual variability and correlates well with intra-atrial cycle length, a parameter which appears to have primary importance in AF maintenance and response to therapy. AF with a low fibrillatory rate is more likely to terminate spontaneously and responds better to antiarrhythmic drugs or cardioversion, whereas high-rate AF is more often persistent and refractory to therapy. Ventricular responses during AF can be characterized by a variety of methods, which include analysis of heart rate variability, RR-interval histograms, Lorenz plots, and non-linear dynamics. These methods have all shown a certain degree of usefulness, either in scientific explorations of atrioventricular (AV) nodal function or in selected clinical questions such as predicting response to drugs, cardioversion, or AV nodal modification. The role of the autonomic nervous system for AF sustenance and termination, as well as for ventricular rate responses, can be explored by different ECG analysis methods. In conclusion, non-invasive characterization of atrial fibrillatory activity and ventricular response can be performed from the surface ECG in AF patients. Different signal processing techniques have been suggested for identification of underlying AF pathomechanisms and prediction of therapy efficacy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A comparison of rate control and rhythm control in patients with atrial fibrillation
(2002) · New England Journal of Medicine · doi:10.1056/nejmoa021328 · Cited by 4,405 · cited 1×
“The concept of ECG-guided AF therapy may gain even greater importance in the light of two studies showing the same mortality risk for rate- and rhythm-control strategies if adequate anticoagulation is performed.(73,74) This highlights the need to select candidates for cardioversion and other interventional procedures…”
BackgroundAtrial Fibrillation Begets Atrial Fibrillation: A Study in Awake Chronically Instrumented Goats
Wijffels, M. C. E. F., Kirchhof, C. J. H. J., Dorland, R., & Allessie, M. A. (1995) · Circulation · doi:10.1161/01.cir.92.7.1954 · Cited by 3,494
Van Gelder, I. C., Hagens, V. E., Bosker, H. A., Kingma, J. H., Kamp, O., Kingma, T., Said, S. A., Darmanata, J. I., Timmermans, A. J. M., Tijssen, J. G. P., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa021375 · Cited by 2,359
ACC/AHA/ESC guidelines for the management of patients with atrial fibrillation: executive summary
Fuster, V., Rydén, L. E., Asinger, R. W., Cannom, D. S., Crijns, H. J., Frye, R. L., Halperin, J. L., Kay, G. N., Klein, W. W., Lévy, S., et al. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01587-x · Cited by 1,348
Bioelectrical Signal Processing in Cardiac and Neurological Applications
(2005) · Elsevier eBooks · doi:10.1016/b978-0-12-437552-9.x5000-4 · Cited by 993
High-density mapping of electrically induced atrial fibrillation in humans.
Konings, K. T., Kirchhof, C. J., Smeets, J. R., Wellens, H. J., Penn, O. C., & Allessie, M. A. (1994) · Circulation · doi:10.1161/01.cir.89.4.1665 · Cited by 962
Fúster, & Westerling, R. (2001) · Circulation · Cited by 607
Committee Members, Fuster, V., Rydén, L. E., Asinger, R. W., Cannom, D. S., Crijns, H. J., Frye, R. L., Halperin, J. L., Kay, G. N., Klein, W. W., et al. (2001) · Circulation · doi:10.1161/circ.104.17.2118 · Cited by 604
High-density mapping of electrically induced atrial fibrillation in humans
Konings, K. T. S., Kirchhof, C. J. H. J., Smeets, J. R. L. M., Wellens, H. J. J., Penn, O. C., & Allessie, M. A. (2000) · Professor Hein J.J. Wellens: 33 Years of Cardiology and Arrhythmology · doi:10.1007/978-94-011-4110-9_54 · Cited by 560
Autonomic tone variations before the onset of paroxysmal atrial fibrillation
Bettoni, M., & Zimmermann, M. (2002) · Circulation · doi:10.1161/01.cir.0000018443.44005.d8 · Cited by 534
Cited by
Alcaraz, R., & Rieta, J. J. (2010) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2009.11.001 · Cited by 194
“Additionally, in those cases where the sampling frequency was originally low, the lead had to be upsampled to 1024 Hz to allow better alignment for QRST complex averaging and subtraction, as suggested in previous works [46].”
ResultSelf-citation
Metadata
- Authors
- Bollmann, A., Husser, D., Mainardi, L., Lombardi, F., Langley, P., Murray, A., Rieta, J. J., Millet, J., Olsson, S. B., Stridh, M., & Sörnmo, L.
- Venue
- EP Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-11-01
- Volume
- 8
- Issue
- 11
- Pages
- 911-926
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2149092351
- Cited by
- 219
- References
- 76
- FWCI
- 12.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis of surface electrocardiograms in atrial fibrillation: techniques, research, and clinical applications. https://app.cochat.ai/papers/10.1093/europace/eul113
- The paper
- Bollmann, A., Husser, D., Mainardi, L., Lombardi, F., Langley, P., Murray, A., Rieta, J. J., Millet, J., Olsson, S. B., Stridh, M., & Sörnmo, L. (2006). Analysis of surface electrocardiograms in atrial fibrillation: techniques, research, and clinical applications. EP Europace. https://doi.org/10.1093/europace/eul113
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).