The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Implantation of cardiac resynchronization therapy systems in the CARE-HF trial: procedural success rate and safety
Open accessAbstract
Aims To assess procedural characteristics and adjudicated procedure-related (30 days) major adverse events among patients who underwent cardiac resynchronization therapy (CRT) implantation in the CARE-HF study.The CARE-HF study shows that CRT improves symptoms and reduces morbidity and mortality in New York Heart Association (NYHA) class III/IV chronic heart failure (CHF) patients.However, safe and proper implantation of pacing systems remains key to effective CRT delivery. Methods and resultsGeneralized linear modeling was used to examine the relationships between first implant success/failure and: NYHA class; beta-adrenergic blocker use; underlying ischemic vs. nonischemic heart disease; history of coronary artery bypass graft or valve surgery; left ventricular (LV) end-diastolic volume vs. .300cm 3 ; and, influence of the participating study-centres.Implantation was attempted in 404/409 patients assigned to CRT, and in 65/404 patients assigned to medical therapy.Among these 469 patients, 450 (95.9%) received a successfully implanted and activated device.Complications occurred within 24 h in 47 patients (10.0%), mainly lead dislodgments (n ¼ 10, 2.1%) and coronary sinus dissection/perforation (n ¼ 10, 2.1%), and between 24 h and 30 days in 26 patients (5.5%), mainly lead dislodgment (n ¼ 13, 2.8%).Mean LV lead stimulation threshold was significantly higher than at the right atrium or right ventricle, though remained stable, delivering effective, and reliable CRT.Implanting experience was the only predictor of procedural outcome.Conclusion Transvenous CRT system implantation, using a CS lead designed for long-term LV pacing, was safe and reliable.As implanting centres become more experienced, this success rate is expected to increase further.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., DeMets, D., White, B. G., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032423 · Cited by 5,812
Cardiac Resynchronization in Chronic Heart Failure
Abraham, W. T., Fisher, W. G., Smith, A. L., Delurgio, D. B., Leon, A. R., Loh, E., Kocovic, D. Z., Packer, M., Clavell, A. L., Hayes, D. L., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013168 · Cited by 4,648
Connolly, S. J., Kerr, C. R., Gent, M., Roberts, R. S., Yusuf, S., Gillis, A. M., Sami, M. H., Talajic, M., Tang, A. S. L., Klein, G. J., et al. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005113421902 · Cited by 775
Cited by
Linde, C., Abraham, W. T., Gold, M. R., St. John Sutton, M., Ghio, S., & Daubert, C. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.08.027 · Cited by 1,261
Authors/Task Force Members, Vardas, P. E., Auricchio, A., Blanc, J.-J., Daubert, J.-C., Drexler, H., Ector, H., Gasparini, M., Linde, C., Morgado, F. B., et al. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm305 · Cited by 902
Self-citationDaubert, J.-C., Saxon, L., Adamson, P. B., Auricchio, A., Berger, R. D., Beshai, J. F., Breithard, O., Brignole, M., Cleland, J., DeLurgio, D. B., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.07.025 · Cited by 467
Self-citationRandomized Trial of Left Bundle Branch vs Biventricular Pacing for Cardiac Resynchronization Therapy
Wang, Y., Zhu, H., Hou, X., Wang, Z., Zou, F., Qian, Z., Wei, Y., Wang, X., Zhang, L., Li, X., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2022.07.019 · Cited by 370
van Rees, J. B., de Bie, M. K., Thijssen, J., Borleffs, C. J. W., Schalij, M. J., & van Erven, L. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.06.007 · Cited by 305
Metadata
- Authors
- Gras, D., Böcker, D., Lunati, M., Wellens, H. J. J., Calvert, M., Freemantle, N., Gervais, R., Kappenberger, L., Tavazzi, L., Erdmann, E., Cleland, J. G. F., & Daubert, J.-C.
- Venue
- EP Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-05-31
- Volume
- 9
- Issue
- 7
- Pages
- 516-522
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2104379361
- Cited by
- 172
- References
- 3
- FWCI
- 8.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implantation of cardiac resynchronization therapy systems in the CARE-HF trial: procedural success rate and safety. https://app.cochat.ai/papers/10.1093/europace/eum080
- The paper
- Gras, D., Böcker, D., Lunati, M., Wellens, H. J. J., Calvert, M., Freemantle, N., Gervais, R., Kappenberger, L., Tavazzi, L., Erdmann, E., Cleland, J. G. F., & Daubert, J.-C. (2007). Implantation of cardiac resynchronization therapy systems in the CARE-HF trial: procedural success rate and safety. EP Europace. https://doi.org/10.1093/europace/eum080
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.