CoChat

Outcome of single-chamber, ventricular pacemakers with transvenous leads implanted in children

Open access
Silvetti, M. S., Drago, F., Marcora, S., Rava, L. · 2007 · Europace
Cited by 35

The DOI matches its Crossref record.

Abstract

AIMS: In children with bradyarrhythmias, ventricular demand, rate-responsive pacemakers (VVI/R PM) are often indicated, but no study is entirely dedicated to their outcome. METHODS AND RESULTS: We evaluated the outcomes of children with VVI/R PM implanted at our centre, with a retrospective analysis. Between 1990 and 2005, 117 children (63 with congenital heart defects), received VVI/R PM with endocardial lead at 5.3 +/- 3.9 years of age for atrioventricular block (n = 105) and sinus node dysfunction. The majority of the leads were unipolar (n = 78), tined (n = 110), and steroid eluting (n = 89). The leads were fixed to subcutaneous tissues by absorbable suture in all patients; in 17 patients, also an atrial loop was created. Follow-up (FU) was 7.8 +/- 4.1 years. There were 22 system failures (19%), due to lead malfunction (n = 20) and system erosion/infection. The log-rank test for equality of survivor functions showed no significant risk factor. However, lead malfunction occurred only in the group without loop, but FU duration was longer in these patients. Complications at implantation were haemothorax (2.5%) and lead dislodgement (5%). Clinically silent occlusion of the subclavian vein was documented at FU by Echo-Doppler in 5%. CONCLUSION: In this particular group of patients, VVI/R pacing has good results, but after long-term FU shows 19% of failures, mainly lead-related.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/europace/eum164

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 35

Metadata

Authors
Silvetti, M. S., Drago, F., Marcora, S., & Rava, L.
Venue
Europace
Published
2007-06-08
Volume
9
Issue
10
Pages
894-899
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W2167067788
Cited by
35
References
0
FWCI
0.22
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Outcome of single-chamber, ventricular pacemakers with transvenous leads implanted in children. https://app.cochat.ai/papers/10.1093/europace/eum164
The paper
Silvetti, M. S., Drago, F., Marcora, S., & Rava, L. (2007). Outcome of single-chamber, ventricular pacemakers with transvenous leads implanted in children. Europace. https://doi.org/10.1093/europace/eum164

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.