The use of an integrated electroanatomic mapping system and intracardiac echocardiography to reduce radiation exposure in children and young adults undergoing ablation of supraventricular tachycardia
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
AIMS: Non-fluoroscopic imaging (NFI) devices are increasingly used in ablations. The objective was to determine the utility of intracardiac echocardiography (ICE) in ablating paediatric supraventricular tachycardias (SVTs) and assess whether its integrated use with electroanatomic mapping (EAM) resulted in lower radiation exposure than use of EAM alone. METHODS AND RESULTS: Prospective, controlled, single-centre study of patients (pts) age ≥10 years, weight ≥35 kg, with SVT and normal cardiac anatomy. Patients were randomized to ICE + EAM (ICE) or EAM only (no ICE). Both had access to fluoroscopy as needed. Eighty-four pts were enroled (42 ICE, 42 no ICE). Median age was 15 years (range 10.4-23.7 years); 57% had accessory pathways, 42% atrioventricular nodal reentry tachycardia. There was no difference in radiation dose (9 mGy ICE vs. 23 mGy no ICE, P = 0.37) or fluoroscopy time (1.1 min ICE vs. 1.5 min no ICE, P = 0.38). Transseptal punctures were performed in 25 pts (16 ICE, 9 no ICE), with ICE reducing radiation (8 mGy ICE vs. 62 mGy no ICE, P = 0.002) and fluoroscopy time (1.1 min ICE vs. 4.5 min no ICE, P = 0.01). Zero fluoroscopy was achieved in 13 pts (15% of total, 5 ICE, 8 no ICE), and low-dose cases (<50 mGy) in 57 pts (68% of total, 33 ICE, 24 no ICE). Acute success was 95% for ICE, 88% for no ICE. CONCLUSION: Use of an integrated EAM/ICE system was no better than EAM alone in limiting radiation, but can be helpful for transseptal punctures. Given the low dose savings, use of ICE may be weighed against its financial cost. Low-fluoroscopy cases are performed in most NFI procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pearce, M. S., Salotti, J. A., Little, M. P., McHugh, K., Lee, C., Kim, K. P., Howe, N. L., Ronckers, C. M., Rajaraman, P., Craft, A. W., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60815-0 · Cited by 3,735
Cited by
Page, R. L., Joglar, J. A., Caldwell, M. A., Calkins, H., Conti, J. B., Deal, B. J., Estes, N. A. M., Field, M. E., Goldberger, Z. D., Hammill, S. C., et al. (2016) · Circulation · doi:10.1161/cir.0000000000000311 · Cited by 595
2015 ACC/AHA/HRS Guideline for the Management of Adult Patients With Supraventricular Tachycardia
Page, R. L., Joglar, J. A., Caldwell, M. A., Calkins, H., Conti, J. B., Deal, B. J., Estes, N. A. M., Field, M. E., Goldberger, Z. D., Hammill, S. C., et al. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.08.856 · Cited by 439
Philip Saul, J., Kanter, R. J., Abrams, D., Asirvatham, S., Bar-Cohen, Y., Blaufox, A. D., Cannon, B., Clark, J., Dick, M., Freter, A., et al. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2016.02.009 · Cited by 272
Self-citation2015 ACC/AHA/HRS guideline for the management of adult patients with supraventricular tachycardia
Page, R. L., Joglar, J. A., Caldwell, M. A., Calkins, H., Conti, J. B., Deal, B. J., Estes III, N. A. M., Field, M. E., Goldberger, Z. D., Hammill, S. C., et al. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2015.09.019 · Cited by 206
Lampert, R., Chung, E. H., Ackerman, M. J., Arroyo, A. R., Darden, D., Deo, R., Dolan, J., Etheridge, S. P., Gray, B. R., Harmon, K. G., et al. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.05.018 · Cited by 167
Metadata
- Authors
- Mah, D. Y., Miyake, C. Y., Sherwin, E. D., Walsh, A., Anderson, M. J., Western, K., Abrams, D. J., Alexander, M. E., Cecchin, F., Walsh, E. P., & Triedman, J. K.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-08-08
- Volume
- 16
- Issue
- 2
- Pages
- 277-283
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2034935887
- Cited by
- 72
- References
- 1
- FWCI
- 4.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.