Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 186

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

His or para-His pacing preserves left ventricular function in atrioventricular block: a double-blind, randomized, crossover study

Open access
Kronborg, M. B., Mortensen, P. T., Poulsen, S. H., Gerdes, J. C., Jensen, H. K., Nielsen, J. C. · 2014 · Europace

Abstract

AIMS: To compare left ventricular function after a long-term His or para-His pacing (HP) and right ventricular septal pacing (RVSP) in patients with atrioventricular block (AVB). METHODS AND RESULTS: We included consecutive patients with AVB, a narrow QRS < 120 ms, and a preserved left ventricular ejection fraction (LVEF) >0.40, in a prospective, randomized, double-blinded, crossover design. All patients were treated with 12 months HP and 12 months RVSP. A total of 38 patients [mean age, 67 ± 10 years; 30 (79%) men] were included. The primary endpoint was LVEF, which was significantly lower after a 12 months RVSP (0.50 ± 0.11) than after 12 months of HP (0.55 ± 0.10), P = 0.005. We measured the difference in time-to-peak systolic velocity between opposite basal segments in the apical views by using tissue Doppler imaging. In the four-chamber view, the difference was 58 (±7) ms after RVSP and 49 (±7) ms after HP, P = 0.27; in the two-chamber view, the difference was 45 (±5) ms after RVSP and 31 ±(4) ms after HP, P = 0.02, and in the apical long-axis view, the difference was 63 (±6) after RVSP and 44 (±7) after HP, P = 0.03. There was no difference in New York Heart Association class, 6-min hall walk test, quality-of-life assessments, or device-related complications. The mean threshold was significantly higher in HP leads than in RVSP leads. CONCLUSION: His or para-His pacing preserves LVEF and mechanical synchrony as compared with RVSP after 12 months pacing in patients with AVB, narrow QRS, and LVEF > 0.40.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/europace/euu011

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 186

Metadata

Authors
Kronborg, M. B., Mortensen, P. T., Poulsen, S. H., Gerdes, J. C., Jensen, H. K., & Nielsen, J. C.
Venue
Europace
Published
2014-02-07
Volume
16
Issue
8
Pages
1189-1196
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W2114164170
Cited by
186
References
1
FWCI
4.84
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: His or para-His pacing preserves left ventricular function in atrioventricular block: a double-blind, randomized, crossover study. https://app.cochat.ai/papers/10.1093/europace/euu011
The paper
Kronborg, M. B., Mortensen, P. T., Poulsen, S. H., Gerdes, J. C., Jensen, H. K., & Nielsen, J. C. (2014). His or para-His pacing preserves left ventricular function in atrioventricular block: a double-blind, randomized, crossover study. Europace. https://doi.org/10.1093/europace/euu011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.