The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Safety and outcome of very high-power short-duration ablation using 70 W for pulmonary vein isolation in patients with paroxysmal atrial fibrillation
Abstract
Aims: Pulmonary vein isolation (PVI) using radiofrequency ablation (RFA) in patients with paroxysmal atrial fibrillation (PAF) is effective but hampered by pulmonary vein reconnection due to insufficient ablation lesions. High-power delivery over a short period of time (HPSD) in RFA is stated to create more efficient lesions. The aim of this study was to compare intraprocedural safety and outcome of HPSD ablation to conventional power settings in patients undergoing PVI for PAF. Methods and results: We included 197 patients with PAF that were scheduled for PVI. An ablation protocol with 70 W and a duration cut-off of 7 s at the anterior left atrium (LA) and 5 s at the posterior LA (HPSD group; n = 97) was compared to a conventional power protocol with 30–40 W for 20–40 s (standard group; n = 100) in terms of periprocedural complications and a 1-year outcome. The HPSD group showed significantly less arrhythmia recurrence during 1-year follow-up with 83.1% of patients free from atrial fibrillation compared to 65.1% in the standard group (P < 0.013). No pericardial tamponade, periprocedural thromboembolic complications, or atrio-oesophageal fistula occurred in either group. Mean radiofrequency time (12.4 ± 3.4 min vs. 35.6 ± 12.1 min) and procedural time (89.5 ± 23.9 min vs. 111.15 ± 27.9 min) were significantly shorter in the HPSD group compared to the standard group (both P < 0.001). Conclusion: High-power short-duration ablation demonstrated a comparable safety profile to conventional ablation. High-power short-duration ablation using 70 W for 5–7 s leads to significantly less arrhythmia recurrences after 1 year. Radiofrequency and procedural time were significantly shortened.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Approaches to catheter ablation for persistent atrial fibrillation
Verma, A., Jiang, C.-Y., Betts, T. R., Chen, J., Deisenhofer, I., Mantovan, R., Macle, L., Morillo, C. A., Haverkamp, W., Weerasooriya, R., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1408288 · Cited by 2,339
Self-citationMacle, L., Khairy, P., Weerasooriya, R., Novak, P., Verma, A., Willems, S., Arentz, T., Deisenhofer, I., Veenhuyzen, G., Scavée, C., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)60026-5 · Cited by 226
Self-citation
Cited by
Tzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Sepehri Shamloo, A., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Europace · doi:10.1093/europace/euae043 · Cited by 634
Self-citationTzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Shamloo, A. S., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.03.017 · Cited by 298
Self-citation
Metadata
- Authors
- Kottmaier, M., Popa, M., Bourier, F., Reents, T., Cifuentes, J., Semmler, V., Telishevska, M., Otgonbayar, U., Koch-Büttner, K., Lennerz, C., Bartkowiak, M., Kornmayer, M., Rousseva, E., Brkic, A., Grebmer, C., Kolb, C., Hessling, G., & Deisenhofer, I.
- Venue
- EP Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2019-12-23
- Volume
- 22
- Issue
- 3
- Pages
- 388-393
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2997344815
- Cited by
- 170
- References
- 2
- FWCI
- 15.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Safety and outcome of very high-power short-duration ablation using 70 W for pulmonary vein isolation in patients with paroxysmal atrial fibrillation. https://app.cochat.ai/papers/10.1093/europace/euz342
- The paper
- Kottmaier, M., Popa, M., Bourier, F., Reents, T., Cifuentes, J., Semmler, V., Telishevska, M., Otgonbayar, U., Koch-Büttner, K., Lennerz, C., Bartkowiak, M., Kornmayer, M., Rousseva, E., Brkic, A., Grebmer, C., Kolb, C., Hessling, G., & Deisenhofer, I. (2020). Safety and outcome of very high-power short-duration ablation using 70 W for pulmonary vein isolation in patients with paroxysmal atrial fibrillation. EP Europace. https://doi.org/10.1093/europace/euz342
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.