CoChat

Identification of Peripheral Vascular Disease in Elderly Subjects Using Optical Spectroscopy

McCully, K. K., Landsberg, L., Suarez, M., Hofmann, M., Posner, J. D. · 1997 · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences
Cited by 64

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The purpose of this study was to determine the usefulness of near-infrared spectroscopy (NIRS) measurements to identify peripheral vascular disease (PVD). Usefulness was determined by the frequency of a successful test, as well as comparison with standard clinical assessments. Study subjects (N = 117, mean age = 67.8 +/- 8.1 yrs) responded to a free screening for PVD. NIRS was used to measure the relative O2 saturation of hemoglobin in the soleus muscle. The time to 1/2 recovery of O2 saturation (O2T1/2) was measured after 1 minute of repeated plantar flexions using a Cybex Eagle seated calf machine. O2T1/2 was used as many subjects had recovery curves that did not have an exponential line shape. The test was done on both legs and the worst leg was used for analysis. For comparative purposes, a clinical history and physical examination were performed by a physician or nurse practitioner, which included questions on intermittent claudication, examination of peripheral pulses, and questions to identify cardiovascular risk factors. NIRS signals were obtained on 105 of 117 subjects (89% success rate). Subjects with body mass index (BMI) values above 32 appeared to have NIRS O2T1/2 values that were less reliable than subjects with BMI values < or = 32 (77% success rate). The O2T1/2 was longer in subjects with claudication and reduced pulses than in subjects without these conditions. Sensitivity comparing O2T1/2 to claudication and reduced pulse varied from 51-76% and specificity from 65-80%, depending on the cutoff value for O2T1/2 that was used (normal value plus 1 or 2 SD). A longer O2T1/2 was significantly associated with incidence of diabetes, smoking, hypercholesterol, and coronary bypass surgery. In summary, successful NIRS O2T1/2 measurements were made in 77% of the subjects, with failure primarily occurring in obese subjects. NIRS O2T1/2 measurements showed reasonable although not strong agreements with clinical assessment of PVD, and with some risk factors for cardiovascular disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/gerona/52a.3.b159

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 64

Metadata

Authors
McCully, K. K., Landsberg, L., Suarez, M., Hofmann, M., & Posner, J. D.
Venue
The Journals of Gerontology Series A: Biological Sciences and Medical Sciences
Published
1997-05-01
Volume
52A
Issue
3
Pages
B159-B165
ISSN
  • 1079-5006 (ISSN-L)
  • 1758-535X
OpenAlex
W2154988301
Cited by
64
References
2
FWCI
0.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Identification of Peripheral Vascular Disease in Elderly Subjects Using Optical Spectroscopy. https://app.cochat.ai/papers/10.1093/gerona/52a.3.b159
The paper
McCully, K. K., Landsberg, L., Suarez, M., Hofmann, M., & Posner, J. D. (1997). Identification of Peripheral Vascular Disease in Elderly Subjects Using Optical Spectroscopy. The Journals of Gerontology Series A: Biological Sciences and Medical Sciences. https://doi.org/10.1093/gerona/52a.3.b159

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.