Validation of an Armband to Measure Daily Energy Expenditure in Older Adults

Open access
Mackey, D. C., Manini, T. M., Schoeller, D. A., Koster, A., Glynn, N. W., Goodpaster, B. H., Satterfield, S., Newman, A. B., Harris, T. B., Cummings, S. R., for the Health, Aging, and Body Composition Study · 2011 · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences
Cited by 153

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Objective methods to measure daily energy expenditure in studies of aging are needed. We sought to determine the accuracy of total energy expenditure (TEE) and activity energy expenditure (AEE) estimates from the SenseWear Pro armband (SWA) using software versions 6.1 (SWA 6.1) and 5.1 (SWA 5.1) relative to criterion methods in free-living older adults. METHODS: Participants (n = 19, mean age 82.0 years) wore a SWA for a mean ± SD 12.5 ± 1.1 days, including while sleeping. During this same period, criterion values for TEE were assessed with doubly labeled water and for resting metabolic rate (RMR) with indirect calorimetry. AEE was calculated as 0.9 TEE - RMR. RESULTS: For TEE, there was no difference in mean ± SD values from doubly labeled water (2,040 ± 472 kcal/day) versus SWA 6.1 (2,012 ± 497 kcal/day, p = .593) or SWA 5.1 (2,066 ± 474 kcal/day, p = .606); individual values were highly correlated between methods (SWA 6.1 r = .893, p < .001; SWA 5.1 r = .901, p < .001) and demonstrated strong agreement (SWA 6.1 intraclass correlation coefficient = .896; SWA 5.1 intraclass correlation coefficient = .904). For AEE, mean values from SWA 6.1 (427 ± 304 kcal/day) were lower by 26.8% than criterion values (583 ± 242 kcal/day, p = .003), and mean values from SWA 5.1 (475 ± 299 kcal/day) were lower by 18.5% than criterion values (p = .021); however, individual values were highly correlated between methods (SWA 6.1 r = .760, p < .001; SWA 5.1 r = .786, p < .001) and demonstrated moderate agreement (SWA 6.1 intraclass correlation coefficient = .645; SWA 5.1 intraclass correlation coefficient = .720). Bland-Altman plots identified no systematic bias for TEE or AEE. CONCLUSIONS: Acceptable levels of agreement were observed between SWA and criterion measurements of TEE and AEE in older adults.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/gerona/glr101

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 153

Metadata

Authors
Mackey, D. C., Manini, T. M., Schoeller, D. A., Koster, A., Glynn, N. W., Goodpaster, B. H., Satterfield, S., Newman, A. B., Harris, T. B., Cummings, S. R., & for the Health, A.
Venue
The Journals of Gerontology Series A: Biological Sciences and Medical Sciences
Published
2011-07-06
Volume
66A
Issue
10
Pages
1108-1113
ISSN
  • 1079-5006 (ISSN-L)
  • 1758-535X
OpenAlex
W2169900296
Cited by
153
References
1
FWCI
8.47
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of an Armband to Measure Daily Energy Expenditure in Older Adults. https://app.cochat.ai/papers/10.1093/gerona/glr101
The paper
Mackey, D. C., Manini, T. M., Schoeller, D. A., Koster, A., Glynn, N. W., Goodpaster, B. H., Satterfield, S., Newman, A. B., Harris, T. B., Cummings, S. R., & for the Health, A. (2011). Validation of an Armband to Measure Daily Energy Expenditure in Older Adults. The Journals of Gerontology Series A: Biological Sciences and Medical Sciences. https://doi.org/10.1093/gerona/glr101

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.