CoChat

Morphometric dimensions of the human sperm head depend on the staining method used

Maree, L., du Plessis, S. S., Menkveld, R., van der Horst, G. · 2010 · Human Reproduction
Cited by 154

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Assessment of sperm morphology (including morphometry) is extensively used to determine one of the qualities of a semen sample and depends on the differential staining of spermatozoa. A staining technique should cause as little change to sperm dimensions and form as possible in order to reliably evaluate the morphometric features of the sperm. Various staining techniques have been employed, but only a few have been recommended by the World Health Organization and are amenable to automated sperm morphometry analysis. Our study was aimed at comparing the effect of three staining techniques [Papanicolaou (PAP), Rapidiff (RD) and SpermBlue (SB)] on human sperm head dimensions and to compare these with the head dimensions in fresh semen. METHODS: Smears made from human semen samples (n = 24) were stained according to the three staining techniques and sperm head morphometry was assessed with the Sperm Class Analyzer. Head dimensions of fresh spermatozoa were measured with a digital calliper on a computer screen. The minimum number of spermatozoa to be analyzed to represent the sperm population and the degree of inter-laboratory variation were determined. Electron micrographs from the same semen samples were used to determine the actual acrosome coverage of the spermatozoa in the semen (n = 7) in order to verify the results of the automatic analyses. RESULTS: The osmolality of human semen differs from that of the RD and PAP fixatives and stains, but is more similar to the SB fixative and stain. At least 100 spermatozoa should be analyzed to include a representative sample of the sperm population. RD caused sperm heads to swell, PAP caused them to shrink and SB had no significant effect on sperm head dimensions when compared with spermatozoa in fresh semen. Very little inter-laboratory variations were found. The percentage acrosome coverage was significantly different between the three staining techniques, as well as between the RD and PAP stains and the manual measurements obtained using the electron micrographs. CONCLUSIONS: Different staining techniques change the morphometric dimensions of the human sperm head, probably due to the fact that either the fixatives or stains are not iso-osmotic in relation to human semen. Since these changes in sperm head dimensions are not uniform, care should be taken when selecting a staining technique. Ideally, stained spermatozoa should have dimensions as close to spermatozoa in fresh semen as possible, as was found with the SB staining method, resulting in accurate evaluations of sperm head morphometry.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/humrep/deq075

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 154

Metadata

Authors
Maree, L., du Plessis, S. S., Menkveld, R., & van der Horst, G.
Venue
Human Reproduction
Published
2010-04-17
Volume
25
Issue
6
Pages
1369-1382
ISSN
  • 0268-1161 (ISSN-L)
  • 1460-2350
OpenAlex
W2164498524
Cited by
154
References
3
FWCI
8.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Morphometric dimensions of the human sperm head depend on the staining method used. https://app.cochat.ai/papers/10.1093/humrep/deq075
The paper
Maree, L., du Plessis, S. S., Menkveld, R., & van der Horst, G. (2010). Morphometric dimensions of the human sperm head depend on the staining method used. Human Reproduction. https://doi.org/10.1093/humrep/deq075

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.