CoChat

The prediction of pouch of Douglas obliteration using offline analysis of the transvaginal ultrasound 'sliding sign' technique: inter- and intra-observer reproducibility

Open access
Reid, S., Lu, C., Casikar, I., Mein, B., Magotti, R., Ludlow, J., Benzie, R., Condous, G. · 2013 · Human Reproduction
Cited by 64

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

STUDY QUESTION: What is the inter-/intra-observer agreement and diagnostic accuracy among gynaecological and non-gynaecological ultrasound specialists in the prediction of pouch of Douglas (POD) obliteration (secondary to endometriosis) at offline analysis of two-dimensional videos using the dynamic real-time transvaginal ultrasound (TVS) 'sliding sign' technique? SUMMARY ANSWER: The inter-/intra-observer agreement and diagnostic accuracy for the interpretation of the TVS 'sliding sign' in the prediction of POD obliteration was found to be very acceptable, ranging from substantial to almost perfect agreement for the observers who specialized in gynaecological ultrasound. WHAT IS KNOWN ALREADY: Women with POD obliteration at laparoscopy are at an increased risk of bowel endometriosis; therefore, the pre-operative diagnosis of POD obliteration is important in the surgical planning for these women. Previous studies have used TVS to predict POD obliteration prior to laparoscopy, with a sensitivity of 72-83% and specificity of 97-100%. However, there have not been any reproducibility studies performed to validate the use of TVS in the prediction of POD obliteration pre-operatively. STUDY DESIGN, SIZE, DURATION: This was a reproducibility study which involved the offline viewing of pre-recorded video sets of 30 women presenting with chronic pelvic pain, in order to determine POD obliteration using the TVS 'sliding sign' technique. The videos were selected on real-time representative quality/quantity; they were not obtained from sequential patients. There were a total of six observers, including four gynaecological ultrasound specialists and two fetal medicine specialists. The study was conducted over a period of 1 month (March 2012-April 2012). PARTICIPANTS/MATERIALS, SETTING, METHODS: The four gynaecological ultrasound observers performed daily gynaecological scanning, while the other two observers were primarily fetal medicine sonologists. Each sonologist viewed the TVS 'sliding sign' video in two anatomical locations (retro-cervix and posterior uterine fundus), i.e. 60 videos in total. The POD was deemed not obliterated, if 'sliding sign' was positive in both anatomical locations (i.e. anterior rectum/rectosigmoid glided smoothly across the retro-cervix/posterior fundus, respectively). If the 'sliding sign' was negative (i.e. anterior rectum/rectosigmoid did not glide smoothly over retro-cervix/posterior fundal region, respectively), the POD was deemed obliterated. Diagnostic accuracy and inter-observer agreement among the six sonologists was evaluated. The same sonologist was also asked to reanalyse the same videos, albeit in a different order, at least 7 days later to assess for intra-observer agreement. A separate analysis of the inter- and intra-observer correlation was also performed to determine the agreement among the four observers who specialized in gynaecological ultrasound. Cohen's κ coefficient <0 meant that there was poor agreement, 0.01-0.20 slight agreement, 0.21-0.40 fair agreement, 0.41-0.60 moderate agreement, 0.61-0.80 substantial agreement and 0.81-0.99 almost perfect agreement. MAIN RESULTS AND THE ROLE OF CHANCE: Agreement (Cohen's κ) between all six observers for the interpretation of the 'sliding sign' for both sets of videos in both regions (retro-cervix and fundus) ranged from 0.354 to 0.927 (fair agreement to almost perfect agreement) compared with 0.630-0.927 (substantial agreement to almost perfect agreement) when only the gynaecological sonologists were included. The overall multiple rater agreement for the interpretation of the 'sliding sign' for both video sets and both regions was Fleiss' κ 0.454 (P-value <0.01) for all six observers and 0.646 (P-value <0.01) for the four gynaecological ultrasound specialists. The multiple rater agreement for all six or all four observers was higher for the retro-cervical region versus the fundal region (Fleiss' κ 0.542 versus 0.370 and 0.732 versus 0.560, respectively). The intra-observer agreement among the six observers for the interpretation of the 'sliding sign' and prediction of POD obliteration ranged from Cohen's κ 0.60-0.95 and 0.46-1.0 (P-value <0.01), respectively. After excluding the fetal medicine specialists, the intra-observer agreement for the interpretation of the 'sliding sign' and the prediction of POD obliteration ranged from Cohen's κ 0.71-0.95 and 0.67-1.0, respectively, indicating substantial to almost perfect agreement. When comparing the four gynaecological observers for the prediction of POD obliteration using the TVS 'sliding sign' (after excluding cases with the POD outcome classified as 'unsure' by the observers), the results for accuracy, sensitivity, specificity, positive and negative predictive value were 93.1-100, 92.9-100, 90.9-100, 77.8-100 and 97.7-100%, respectively. LIMITATIONS, REASONS FOR CAUTION: The 'gold standard' for the diagnosis of POD obliteration is laparoscopy; however, laparoscopic data were ava

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/humrep/det044

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 64

Metadata

Authors
Reid, S., Lu, C., Casikar, I., Mein, B., Magotti, R., Ludlow, J., Benzie, R., & Condous, G.
Venue
Human Reproduction
Published
2013-03-12
Volume
28
Issue
5
Pages
1237-1246
ISSN
  • 0268-1161 (ISSN-L)
  • 1460-2350
OpenAlex
W2137603770
Cited by
64
References
3
FWCI
7.43
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.