CoChat

Extracorporeal membrane oxygenation with spontaneous breathing as a bridge to lung transplantation

Open access
Nosotti, M., Rosso, L., Tosi, D., Palleschi, A., Mendogni, P., Nataloni, I. F., Crotti, S., Tarsia, P. · 2013 · Interactive CardioVascular and Thoracic Surgery
Cited by 103

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: A large number of transplantation centres consider extracorporeal membrane oxygenation as an inappropriate option for bridging critical patients to lung transplantation. Technical improvements such as the introduction of a polymethylpentene membrane, new centrifugal pumps and heparin-coated circuits have led to a safer application of extracorporeal membrane oxygenation, and an increasing number of centres are reporting their positive experiences. The aim of this study was to review our practice in bridging critical candidates to lung transplantation with extracorporeal membrane oxygenation, by comparing patients with invasive mechanical ventilation with patients with spontaneous breathing. METHODS: The records of candidates for lung transplantation treated with extracorporeal membrane oxygenation have been revised. RESULTS: From February 2008 to 2012, 11 patients who experienced an abrupt worsening of their respiratory conditions were treated with extracorporeal membrane oxygenation; mean age: 33.9 ± 13.2 years, male/female ratio: 5/6, 6 patients were affected by cystic fibrosis, 2 had chronic rejection after transplantation, 2 had pulmonary fibrosis and 1 had systemic sclerosis. Seven patients were awake, while 4 patients received invasive mechanical ventilation. The sequential organ failure assessment score significantly increased during bridging time and this increase was significantly higher in the intubated patients. All the patients had bilateral lung transplantation. Spontaneously breathing patients showed a tendency to require a shorter duration of invasive mechanical ventilation, intensive care unit stay and hospital stay after transplantation. One-year survival rate was 85.7% in patients with spontaneous breathing vs 50% in patients with invasive mechanical ventilation. CONCLUSIONS: Extracorporeal membrane oxygenation in spontaneously breathing patients is a feasible, effective and safe bridge to lung transplantation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/icvts/ivs433

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 103

Metadata

Authors
Nosotti, M., Rosso, L., Tosi, D., Palleschi, A., Mendogni, P., Nataloni, I. F., Crotti, S., & Tarsia, P.
Venue
Interactive CardioVascular and Thoracic Surgery
Published
2012-10-24
Volume
16
Issue
1
Pages
55-59
ISSN
  • 1569-9285 (ISSN-L)
  • 1569-9293
OpenAlex
W2144292699
Cited by
103
References
3
FWCI
9.92
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Extracorporeal membrane oxygenation with spontaneous breathing as a bridge to lung transplantation. https://app.cochat.ai/papers/10.1093/icvts/ivs433
The paper
Nosotti, M., Rosso, L., Tosi, D., Palleschi, A., Mendogni, P., Nataloni, I. F., Crotti, S., & Tarsia, P. (2013). Extracorporeal membrane oxygenation with spontaneous breathing as a bridge to lung transplantation. Interactive CardioVascular and Thoracic Surgery. https://doi.org/10.1093/icvts/ivs433

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.