CoChat

Pacemaker dependency after isolated aortic valve replacement: do conductance disorders recover over time?†

Open access
Baraki, Hassina, Al Ahmad, Ammar, Jeng-Singh, Stefan, Saito, Shunsuke, Schmitto, Jan Dieter, Fleischer, Bernhard, Haverich, Axel, Kutschka, Ingo · 2013 · Interactive CardioVascular and Thoracic Surgery
Cited by 50

The DOI matches its Crossref record.

Abstract

OBJECTIVES: Permanent pacemaker (PPM) implantation is required in 3-8% of all patients undergoing aortic valve replacement (AVR). Our aim was to evaluate long-term PPM dependency and recovery of atrioventricular (AV) conduction disorders during follow-up in these patients. METHODS: Since January 1997, a total of 2106 consecutive patients underwent isolated AVR at our institution. Of these, 138 patients (6.6%, 72 female, median age 71 (37-89) years) developed significant conduction disorders leading to PPM implantation postoperatively. Preoperative ECG showed normal sinus rhythm (n = 64), first degree AV block (n = 19), left bundle branch block (n = 13), right bundle branch block (n = 16), left anterior hemiblock (n = 14) and AV block with ventricular escape rhythm (n = 10). Atrial fibrillation was present in 23 patients. Pacemakers were implanted after a median of 7 (1-30) days following AVR. PPM dependency was analysed by ECG and pacemaker check during follow-up. RESULTS: A total of 45 of 138 patients with postoperative PPM Implantation died during a mean follow-up time of 5.3 ± 4.7 years. A further 9 patients were lost to follow-up. Long-term survivals at 1, 5 and 10 years were 88%, 79% and 59%, respectively. Only 8 (10%) of 84 survivors were no longer pacemaker-dependent. The majority of patients (n = 66, 79%) required permanent ventricular stimulation, and the remaining 10 (13%) showed intermittent stimulation with a mean ventricular stimulation fraction of 73% (22-98%). CONCLUSIONS: The majority of patients do not recover from AV conduction disorders after AVR. Since higher-grade AV blocks expose patients to a high risk of sudden death after surgery, we recommend early implantation of permanent pacemaker.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/icvts/ivs555

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 50

Metadata

Authors
Baraki, H., Al Ahmad, A., Jeng-Singh, S., Saito, S., Schmitto, J. D., Fleischer, B., Haverich, A., & Kutschka, I.
Venue
Interactive CardioVascular and Thoracic Surgery
Published
2013-01-08
Volume
16
Issue
4
Pages
476-481
ISSN
  • 1569-9285 (ISSN-L)
  • 1569-9293
OpenAlex
W2104966562
Cited by
50
References
0
FWCI
2.75
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pacemaker dependency after isolated aortic valve replacement: do conductance disorders recover over time?†. https://app.cochat.ai/papers/10.1093/icvts/ivs555
The paper
Baraki, H., Al Ahmad, A., Jeng-Singh, S., Saito, S., Schmitto, J. D., Fleischer, B., Haverich, A., & Kutschka, I. (2013). Pacemaker dependency after isolated aortic valve replacement: do conductance disorders recover over time?†. Interactive CardioVascular and Thoracic Surgery. https://doi.org/10.1093/icvts/ivs555

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.