CoChat

The concentration-independent effect of monoexponential and biexponential decay in vancomycin concentrations on the killing of Staphylococcus aureus under aerobic and anaerobic conditions

Open access
Larsson, Alison J., Walker, Karla J., Raddatz, Janet K., Rotschafer, John C. · 1996 · Journal of Antimicrobial Chemotherapy
Cited by 105

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

An in-vitro pharmacodynamic system was used to generate time-kill curves to demonstrate the concentration-independent pharmacodynamics of vancomycin against Staphylococcus aureus ATCC 29213. Initial vancomycin concentrations of 5, 10, 20 and 40 mg/L were studied monoexponentially while simulating a 6 h half-life. One parallel experiment was performed in duplicate using an initial peak concentration of 40 mg/L where both a distribution alpha-phase half-life of 0.66 h for 1 h and an elimination beta-phase half-life of 6 h for 11 h were simulated to determine if the transient distribution phase concentrations of vancomycin have any impact on bacterial killing beyond that provided by the elimination phase concentrations. Additionally, two monoexponential experiments with peak concentrations of 40 and 20 mg/L and a half-life of 6 h were repeated in an anaerobic chamber to determine if killing of S. aureus was affected. The time to achieve a 3 log10 kill was calculated from the linear portion of the regression line and averaged (mean +/- S.D.) 9.0 +/- 1.4 h for all aerobic monoexponential experiments and was 8.4 and 8.6 h for the aerobic biexponential experiments (P > 0.05). For the anaerobic studies, the times to reach 3 log10 kill were significantly greater averaging 18.9 +/- 1.7 h. The slopes of the bacterial kill curves were virtually identical for both monoexponential and biexponential aerobic experiments averaging -0.34 +/- 0.04, yet significantly different from the anaerobic bacterial kill curve slopes of -0.16 +/- 0.015 (P < 0.05). Time-kill curve analyses suggest that varying the concentration of vancomycin does not affect the rate or extent of bacterial killing aerobically or anaerobically against S. aureus and more efficient killing was achieved under aerobic conditions. The simulated distribution phase concentrations did not contribute to more effective killing of this strain of S. aureus.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/jac/38.4.589

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 105

Metadata

Authors
Larsson, A. J., Walker, K. J., Raddatz, J. K., & Rotschafer, J. C.
Venue
Journal of Antimicrobial Chemotherapy
Published
1996
Volume
38
Issue
4
Pages
589-597
ISSN
  • 0305-7453 (ISSN-L)
  • 1460-2091
OpenAlex
W2168813441
Cited by
105
References
2
FWCI
0.90
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.