Abstract

Objective: The study objective was to evaluate the accuracy, validity, and clinical usefulness of medication error alerts generated by an alerting system using outlier detection screening. Materials and Methods: Five years of clinical data were extracted from an electronic health record system for 747 985 patients who had at least one visit during 2012–2013 at practices affiliated with 2 academic medical centers. Data were screened using the system to detect outliers suggestive of potential medication errors. A sample of 300 charts was selected for review from the 15 693 alerts generated. A coding system was developed and codes assigned based on chart review to reflect the accuracy, validity, and clinical value of the alerts. Results: Three-quarters of the chart-reviewed alerts generated by the screening system were found to be valid in which potential medication errors were identified. Of these valid alerts, the majority (75.0%) were found to be clinically useful in flagging potential medication errors or issues. Discussion: A clinical decision support (CDS) system that used a probabilistic, machine-learning approach based on statistically derived outliers to detect medication errors generated potentially useful alerts with a modest rate of false positives. The performance of such a surveillance and alerting system is critically dependent on the quality and completeness of the underlying data. Conclusion: The screening system was able to generate alerts that might otherwise be missed with existing CDS systems and did so with a reasonably high degree of alert usefulness when subjected to review of patients’ clinical contexts and details.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/jamia/ocw171

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 89

Metadata

Authors
Schiff, G. D., Volk, L. A., Volodarskaya, M., Williams, D. H., Walsh, L., Myers, S. G., Bates, D. W., & Rozenblum, R.
Venue
Journal of the American Medical Informatics Association
Published
2017-01-19
Volume
24
Issue
2
Pages
281-287
ISSN
  • 1067-5027 (ISSN-L)
  • 1527-974X
OpenAlex
W2575766973
Cited by
89
References
2
FWCI
10.31
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Screening for medication errors using an outlier detection system. https://app.cochat.ai/papers/10.1093/jamia/ocw171
The paper
Schiff, G. D., Volk, L. A., Volodarskaya, M., Williams, D. H., Walsh, L., Myers, S. G., Bates, D. W., & Rozenblum, R. (2017). Screening for medication errors using an outlier detection system. Journal of the American Medical Informatics Association. https://doi.org/10.1093/jamia/ocw171

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.