The DOI matches its Crossref record.
Comparison of LECO FP-228 "Nitrogen Determinator" with AOAC Copper Catalyst Kjeldahl Method for Crude Protein
Abstract
The LECO FP-228 "Nitrogen Determinator" was compared with the AOAC copper catalyst Kjeldahl method, 7.033-7.037, for the determination of crude protein in feed materials. The completely microprocessor- controlled instrument determines nitrogen by measuring the nitrogen gas following combustion of the sample; it was easy to operate and broadly applicable. A wide variety of feed materials of various nitrogen levels were analyzed in one mixed sequence. Results were precise, accurate, and rapid. Analysis time for one sample was approximately 3 min. Fourteen samples containing 2.5-15.5% N were selected for study and consisted of meals, grains, forages, and standard organic materials. The overall mean for the 14 samples by the LECO combustion method was 8.61% N compared with an overall mean of 8.58% N for the AOAC Kjeldahl method. Within-sample standard deviations for the LECO combustion method ranged from 0.013 to 0.052% N with a pooled standard deviation (SD) of 0.033% N for the 14 samples. Standard deviations for the AOAC Kjeldahl method ranged from 0.006 to 0.035% N with a pooled SD of 0.022% N. Combined average recovery of nitrogen from tryptophan, lysine- HC1, and EDTA determined by the LECO combustion method was 99.94% compared to 99.88% determined by the AOAC Kjeldahl method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sampling, Handling, and Analyzing Plant Tissue Samples
Jones, J. B., & Case, V. W. (1990) · SSSA Book Series · doi:10.2136/sssabookser3.3ed.c15 · Cited by 1,047
Sáez-Plaza, P., Navas, M. J., Wybraniec, S., Michałowski, T., & Asuero, A. G. (2013) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2012.751787 · Cited by 523
Determination of Nitrogen as Elementary N, an Alternative to Kjeldahl
Hansen, B. (1989) · Acta Agriculturae Scandinavica · doi:10.1080/00015128909438504 · Cited by 396
Kamruzzaman, M., ElMasry, G., Sun, D.-W., & Allen, P. (2012) · Innovative Food Science & Emerging Technologies · doi:10.1016/j.ifset.2012.06.003 · Cited by 273
Tumwegamire, S., Kapinga, R., Rubaihayo, P. R., LaBonte, D. R., Grüneberg, W. J., Burgos, G., Felde, T. Z., Carpio, R., Pawelzik, E., & Mwanga, R. O. M. (2011) · HortScience · doi:10.21273/hortsci.46.3.348 · Cited by 103
Metadata
- Authors
- Sweeney, R. A., & Rexroad, P. R.
- Venue
- Journal of AOAC INTERNATIONAL
- Publisher
- Oxford University Press (OUP)
- Published
- 1987-11-01
- Volume
- 70
- Issue
- 6
- Pages
- 1028-1030
- ISSN
- 0004-5756 (ISSN-L)
- OpenAlex
- W2414722511
- Cited by
- 239
- References
- 0
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of LECO FP-228 "Nitrogen Determinator" with AOAC Copper Catalyst Kjeldahl Method for Crude Protein. https://app.cochat.ai/papers/10.1093/jaoac/70.6.1028
- The paper
- Sweeney, R. A., & Rexroad, P. R. (1987). Comparison of LECO FP-228 "Nitrogen Determinator" with AOAC Copper Catalyst Kjeldahl Method for Crude Protein. Journal of AOAC INTERNATIONAL. https://doi.org/10.1093/jaoac/70.6.1028
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.