Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 308

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Determination of Crude Protein in Animal Feed, Forage, Grain, and Oilseeds by Using Block Digestion with a Copper Catalyst and Steam Distillation into Boric Acid: Collaborative Study

Thiex, Nancy J, Manson, Harold, Anderson, Shirley, Persson, Jan-Åke, Collaborators:, Anderson, S, Bogren, E, Bolek, G, Budde, D, Ellis, C, Eriksson, S, Field, G, Frankenius, E, Henderson, C, Henry, C, Kapphahn, M, Lundberg, L, Manson, H, Moller, J, Russell, M, Sefert-Schwind, J, Spann, M · 2002 · Journal of AOAC INTERNATIONAL

Abstract

A collaborative study was conducted to evaluate the repeatability and reproducibility of an extension of AOAC Official Method 991.20, Nitrogen (Crude) in Milk, to animal feed, forage (plant tissue), grain, and oilseed materials. Test portions are digested in an aluminum block at 420°C in sulfuric acid with potassium sulfate and a copper catalyst. Digests are cooled and diluted, and concentrated sodium hydroxide is added to neutralize the acid and make the digest basic; the liberated ammonia is distilled by using steam distillation. The liberated ammonia is trapped in a weak boric acid solution and titrated with a stronger standardized acid, hydrochloric acid; colorimetric endpoint detection is used. Fourteen blind samples were sent to 13 collaborators in the United States, Denmark, Sweden, Germany, and the United Kingdom. Recoveries of nitrogen from lysine, tryptophan, and acetanilide were 86.8, 98.8, and 100.1%, respectively. The within-laboratory relative standard deviation (RSDr, repeatability) ranged from 0.40 to 2.38% for crude protein. The among-laboratories (including within-) relative standard deviation (RSDR, reproducibility) ranged from 0.44 to 2.38%. It is recommended that the method be adopted First Action by AOAC INTERNATIONAL. A lower concentration (1% H3BO3) of trapping solution was compared with the concentration specified in the original protocol (4% H3BO3) and was found comparable for use in an automatic titration system in which titration begins automatically as soon as distillation starts. The Study Directors recommend that 1% H3BO3 as an optional alternative to 4% boric acid trapping solution be allowed for automatic titrators that titrate throughout the distillation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/jaoac/85.2.309

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 308

Metadata

Authors
Thiex, N. J., Manson, H., Anderson, S., Persson, J.-Å., Collaborators:, Anderson, S., Bogren, E., Bolek, G., Budde, D., Ellis, C., Eriksson, S., Field, G., Frankenius, E., Henderson, C., Henry, C., Kapphahn, M., Lundberg, L., Manson, H., Moller, J., Russell, M., Sefert-Schwind, J., & Spann, M.
Venue
Journal of AOAC INTERNATIONAL
Published
2002-03-01
Volume
85
Issue
2
Pages
309-317
ISSN
  • 1060-3271 (ISSN-L)
  • 1944-7922
OpenAlex
W1518095053
Cited by
308
References
1
FWCI
1.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determination of Crude Protein in Animal Feed, Forage, Grain, and Oilseeds by Using Block Digestion with a Copper Catalyst and Steam Distillation into Boric Acid: Collaborative Study. https://app.cochat.ai/papers/10.1093/jaoac/85.2.309
The paper
Thiex, N. J., Manson, H., Anderson, S., Persson, J.-Å., Collaborators:, Anderson, S., Bogren, E., Bolek, G., Budde, D., Ellis, C., Eriksson, S., Field, G., Frankenius, E., Henderson, C., Henry, C., Kapphahn, M., Lundberg, L., Manson, H., Moller, J., . . . Spann, M. (2002). Determination of Crude Protein in Animal Feed, Forage, Grain, and Oilseeds by Using Block Digestion with a Copper Catalyst and Steam Distillation into Boric Acid: Collaborative Study. Journal of AOAC INTERNATIONAL. https://doi.org/10.1093/jaoac/85.2.309

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.