CoChat

Use of Cotinine Immunoassay Test Strips for Preclassifying Urine Samples from Smokers and Nonsmokers Prior to Analysis by LC-MS-MS*

Bernert, John T., Harmon, Tia L., Sosnoff, Connie S., McGuffey, James E. · 2005 · Journal of Analytical Toxicology
Cited by 64

The DOI matches its Crossref record.

Abstract

Cotinine biomarker measurements involving both smokers and nonsmokers must accommodate a broad range of concentrations. Thus, we have routinely preclassified unknown samples as being either "high" or "low" by using an enzyme-linked immunoassay for cotinine prior to analysis by tandem mass spectrometry (MS). Although this method is effective, it is also time-consuming and complex; a simpler and faster approach would be useful. Consequently, a screening assay for urine cotinine using an immunochromatographic test strip (NicAlert) followed by a computerized analysis of the data was examined as a possible alternative. The results indicate that this approach can provide useful classification efficiency when using our target cutoff value of approximately 20 ng/mL. In the analysis of 50 urine samples from nonsmokers with varying degrees of exposure to environmental tobacco smoke, the classification sensitivity and specificity were 88% and 92%, respectively, for cotinine measured by the test strips relative to total cotinine concentrations measured by atmospheric-pressure ionization tandem MS. However, the relatively high cost of the strips may be a limiting factor.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/jat/29.8.814

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Bernert, J. T., Harmon, T. L., Sosnoff, C. S., & McGuffey, J. E.
Venue
Journal of Analytical Toxicology
Published
2005-11-01
Volume
29
Issue
8
Pages
814-818
ISSN
  • 0146-4760 (ISSN-L)
  • 1945-2403
OpenAlex
W2170655931
Cited by
64
References
0
FWCI
2.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.