CoChat

Detection of JWH-018 and JWH-073 by UPLC-MS-MS in Postmortem Whole Blood Casework

Open access
Shanks, K. G., Dahn, T., Terrell, A. R. · 2012 · Journal of Analytical Toxicology
Cited by 116

The DOI matches its Crossref record.

Abstract

Synthetic cannabinoids have been detected in various herbal blends sold legally in convenience stores, smoke shops, and on the Internet. Many of these compounds have extreme forensic significance. We developed and validated a rapid ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of trace concentrations of two of these compounds, JWH-018 and JWH-073, in human blood. Samples underwent liquid-liquid extraction at pH 10.2 into ethyl ether. Tandem mass spectrometry was performed in positive electrospray ionization mode with multiple reaction monitoring using two transitions and one calculated ion transition ratio for each analyte. Deuterated analogs were used as internal standards. Total run time was 2.6 min. The linear dynamic range was 0.05-50 ng/mL with a limit of detection of 0.01 ng/mL for each analyte. Intra-run imprecision (at two different concentration levels, 2 and 8 ng/mL) was 3.9-10.3% for JWH-018 and 3.5-6.2% for JWH-073. Inter-run imprecision was 6.5-7.2% for JWH-018 and 4.8-5.5% for JWH-073. Intra-run accuracy was 95.9-112.7% for JWH-018 and 92.6-104.7% for JWH-073. Inter-run accuracy was 99.1-107.0% for JWH-018 and 97.7-102.0% for JWH-073. Carryover, exogenous drug interferences, ion suppression and matrix selectivity were also assessed. The method has been applied to postmortem forensic casework received by the laboratory and has proven to be robust and reliable. Concentrations of authentic samples have ranged from 0.1-199 ng/mL for JWH-018 and 0.1-68.3 ng/mL for JWH-073.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/jat/bks013

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 116

Metadata

Authors
Shanks, K. G., Dahn, T., & Terrell, A. R.
Venue
Journal of Analytical Toxicology
Published
2012-03-14
Volume
36
Issue
3
Pages
145-152
ISSN
  • 0146-4760 (ISSN-L)
  • 1945-2403
OpenAlex
W2171939331
Cited by
116
References
0
FWCI
20.51
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection of JWH-018 and JWH-073 by UPLC-MS-MS in Postmortem Whole Blood Casework. https://app.cochat.ai/papers/10.1093/jat/bks013
The paper
Shanks, K. G., Dahn, T., & Terrell, A. R. (2012). Detection of JWH-018 and JWH-073 by UPLC-MS-MS in Postmortem Whole Blood Casework. Journal of Analytical Toxicology. https://doi.org/10.1093/jat/bks013

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.